High-resolution incoherent interference imaging without phase measurement

被引:0
|
作者
Yao, Mulin [1 ,2 ,3 ]
Liu, Shengjie [1 ,2 ,3 ]
Li, Junwei [1 ,2 ,3 ]
Li, Min [1 ,2 ]
Wang, Shengqian [1 ,2 ,3 ]
Wei, Kai [4 ]
Cui, Hao [5 ]
机构
[1] Natl Lab Adapt Opt, Chengdu, Sichuan, Peoples R China
[2] Chinese Acad Sci, Inst Opt & Elect, Chengdu, Sichuan, Peoples R China
[3] Univ Chinese Acad Sci, Sch Optoelect, Beijing, Peoples R China
[4] Zhejiang Univ, Coll Opt Sci & Engn, Hangzhou, Zhejiang, Peoples R China
[5] Univ Elect Sci & Technol China, Sch Optoelect Sci & Engn, Chengdu, Sichuan, Peoples R China
基金
中国国家自然科学基金; 中国科学院西部之光基金;
关键词
complex coherence; image reconstruction; interference imaging; phase retrieval algorithm; RETRIEVAL; ALGORITHMS; THEOREM;
D O I
10.1002/mop.34305
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Aiming for long-distance, high-resolution, passive imaging, we use fiber coupling to replace the spatial coupling of the segmented planar imaging detector for electro-optical reconnaissance imaging system and propose a novel incoherent interference imaging method, which avoids the problem that the resolution of the imaging system is limited by the size of the silicon wafer. The method uses a phase retrieval algorithm and does not need to measure the phase in the system, effectively avoiding the intrinsic jitter problem of fiber optics. The feasibility of the method in achieving target image reconstruction was verified through simulation; furthermore, an indoor two-dimensional discrete sampling imaging experiment for a simple four-rod target was conducted, and an outdoor one-dimensional feature identification experiment for a two-rod target was also performed. The results showed that the resolution exceeds the diffraction limit and the reconstruction error of target size is less than 3.5%.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] HIGH-RESOLUTION SURFACE IMAGING
    MARKS, LD
    ACTA CRYSTALLOGRAPHICA SECTION A, 1984, 40 : C390 - C390
  • [42] High-resolution imaging in epilepsy
    Bronen, RA
    Knowlton, T
    Garwood, M
    Maravilla, KR
    Jack, CR
    EPILEPSIA, 2002, 43 : 11 - 18
  • [43] Polarized high-resolution imaging
    Stephen Ippolito
    Nature Photonics, 2008, 2 : 273 - 274
  • [44] LENSES FOR HIGH-RESOLUTION IMAGING
    REIF, GA
    OPTICAL SPECTRA, 1980, 14 (06): : 63 - 64
  • [45] High-resolution Photoacoustic Imaging
    Kong, Fanting
    Chen, Y. C.
    Lloyd, Harriet O.
    Silverman, Ronald H.
    Kim, Hyung
    Cannata, Jonathan M.
    Shung, K. Kirk
    2009 CONFERENCE ON LASERS AND ELECTRO-OPTICS AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2009), VOLS 1-5, 2009, : 403 - +
  • [46] PARATHYROID IMAGING - COMPARISON OF HIGH-RESOLUTION CT AND HIGH-RESOLUTION SONOGRAPHY
    STARK, DD
    GOODING, GAW
    MOSS, AA
    CLARK, OH
    OVENFORS, CO
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 141 (04) : 633 - 638
  • [47] HIGH-RESOLUTION FLUOROGRAPHIC IMAGING
    COWEN, AR
    CLARKE, OF
    HAYWOOD, JM
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (690): : 570 - 572
  • [48] High-resolution strain imaging
    Noriaki Horiuchi
    Nature Photonics, 2018, 12 : 193 - 193
  • [49] HIGH-RESOLUTION STEREOSCOPIC IMAGING
    SHEPPARD, CJR
    HAMILTON, DK
    APPLIED OPTICS, 1983, 22 (06): : 886 - 887
  • [50] HIGH-RESOLUTION IMAGING OF A CERAMIC
    CONRADI, MS
    JOURNAL OF MAGNETIC RESONANCE, 1991, 93 (02): : 419 - 422