Near Real-Time Estimation of Blood Loss and Flow-Pressure Redistribution during Unilateral Nephrectomy

被引:1
|
作者
Cowley, James [1 ]
Kyeremeh, Justicia [2 ]
Stewart, Grant D. [2 ]
Luo, Xichun [3 ]
Shu, Wenmiao [1 ]
Kazakidi, Asimina [1 ]
机构
[1] Univ Strathclyde, Dept Biomed Engn, Glasgow G4 0NW, Scotland
[2] Univ Cambridge, Dept Surg, Cambridge CB2 0QQ, England
[3] Univ Strathclyde, Ctr Precis Mfg, Dept Design Mfg & Engn Management, Glasgow G1 1XJ, Scotland
基金
英国科研创新办公室;
关键词
blood loss; kidney tumor; renal arteries; vessel cutting; surgery; resection; two-kidney vasculature; simulation; mathematical modelling; lumped-parameter model; blood flux; pressure; ACUTE KIDNEY INJURY; WALL SHEAR-STRESS; TUBULOGLOMERULAR FEEDBACK; MATHEMATICAL-MODEL; ARTERIAL NETWORKS; AUTOREGULATION; DYNAMICS; PATTERNS; HEMODYNAMICS; BIFURCATION;
D O I
10.3390/fluids9090214
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Radical or partial nephrectomy, commonly used for the treatment of kidney tumors, is a surgical procedure with a risk of high blood loss. The primary aim of this study is to quantify blood loss and elucidate the redistribution of blood flux and pressure between the two kidneys and the abdominal aorta during renal resection. We have developed a robust research methodology that introduces a new lumped-parameter mathematical model, specifically focusing on the vasculature of both kidneys using a non-Newtonian Carreau fluid. This model, a first-order approximation, accounts for the variation in the total impedance of the vasculature when various vessels are severed in the diseased kidney (assumed to be the left in this work). The model offers near real-time estimations of the flow-pressure redistribution within the vascular network of the two kidneys and the downstream aorta for several radical or partial nephrectomy scenarios. Notably, our findings indicate that the downstream aorta receives an approximately 1.27 times higher percentage of the redistributed flow from the diseased kidney compared to that received by the healthy kidney, in nearly all examined cases. The implications of this study are significant, as they can inform the development of surgical protocols to minimize blood loss and can assist surgeons in evaluating the adequacy of the remaining kidney vasculature.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Toward near real-time acuity estimation - A feasibility study
    Kim, Hyeoneui
    Harris, Marcelline R.
    Savova, Guergana K.
    Speedie, Stuart M.
    Chute, Christopher G.
    NURSING RESEARCH, 2007, 56 (04) : 288 - 294
  • [22] A real-time algorithm for the quantification of blood pressure waveforms
    Navakatikyan, MA
    Barrett, CJ
    Head, GA
    Ricketts, JH
    Malpas, SC
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (07) : 662 - 670
  • [23] Development and application of a real-time loss estimation framework for Portugal
    Silva, Vitor
    Marques, Mario
    Castro, Jose Miguel
    Varum, Humberto
    BULLETIN OF EARTHQUAKE ENGINEERING, 2015, 13 (09) : 2493 - 2516
  • [24] Development and application of a real-time loss estimation framework for Portugal
    Vitor Silva
    Mário Marques
    José Miguel Castro
    Humberto Varum
    Bulletin of Earthquake Engineering, 2015, 13 : 2493 - 2516
  • [25] Development of a Real-time Analyzer for Peripheral Venous Evaluation during Blood Pressure Measurement
    Kashihara, K.
    2014 IEEE/SICE INTERNATIONAL SYMPOSIUM ON SYSTEM INTEGRATION (SII), 2014, : 88 - 92
  • [26] LOCALIZED REAL-TIME BLOOD-FLOW MEASUREMENTS
    VANAS, H
    BROUWERS, AAM
    SNAAR, JEM
    ARCHIVES INTERNATIONALES DE PHYSIOLOGIE DE BIOCHIMIE ET DE BIOPHYSIQUE, 1985, 93 (05): : 87 - 95
  • [27] Physics driven real-time blood flow simulations
    Sankaran, Sethuraman
    Lesage, David
    Tombropoulos, Rhea
    Xiao, Nan
    Kim, Hyun Jin
    Spain, David
    Schaap, Michiel
    Taylor, Charles A.
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2020, 364
  • [28] The changes in the blood pressure and in the renal blood flow and glomerular filtration rate of hypertensive patients following unilateral nephrectomy
    Friedman, M
    Selzer, A
    Kreutzmann, H
    Sampson, JJ
    JOURNAL OF CLINICAL INVESTIGATION, 1942, 21 (01): : 19 - 24
  • [29] Real-time blood flow estimation using a recursive least-squares lattice filter
    Stetson, PF
    Jensen, JA
    1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, 1997, : 1259 - 1262
  • [30] Real-time tracking of brain oxygen gradients and blood flow during functional activation
    Chong, Sang Hoon
    Ong, Yi Hong
    El Khatib, Mirna
    Allu, Srinivasa Rao
    Parthasarathy, Ashwin B.
    Greenberg, Joel H.
    Yodh, Arjun G.
    Vinogradov, Sergei A.
    NEUROPHOTONICS, 2022, 9 (04)