A quantitative method for aquaporin-1 protein using magnetic preconcentration and probe-based immunoassay coupling to inductively coupled plasma mass spectrometry in urine analysis

被引:0
|
作者
Liang, Shuqi [2 ,4 ]
Zhao, Shuang [1 ]
Liu, Hongtao [2 ]
Liu, Jiahui [1 ]
Xie, Xiuqin [5 ]
Chen, Ruohong [1 ,3 ]
Chen, Baowei [5 ]
Luan, Tiangang [1 ,3 ,6 ]
机构
[1] Sun Yat Sen Univ, Sch Life Sci, Sate Key Lab Biocontrol, Guangzhou 510275, Peoples R China
[2] Sun Yat Sen Univ, Instrumental Anal & Res Ctr, Guangzhou 510275, Peoples R China
[3] Jieyang Ctr, Guangdong Prov Lab Chem & Fine Chem Engn, Jieyang 515200, Peoples R China
[4] Sun Yat Sen Univ, MOE Key Lab Bioinorgan & Synthet Chem, KLGHEI Environm & Energy Chem, Sch Chem,Sch Environm Sci & Engn, Guangzhou 510006, Peoples R China
[5] Sun Yat sen Univ, Sch Marine Sci, Southern Marine Sci & Engn Guangdong Lab Zhuhai, Zhuhai 519082, Peoples R China
[6] Wuyi Univ, Sch Environm & Chem Engn, Jiangmen 529020, Peoples R China
关键词
Aquaporin-1; Probe; Signal amplification; Protein detection; Inductively coupled plasma mass spectrometry; CELL; BIOMARKERS; SCREEN; GOLD;
D O I
10.1016/j.aca.2024.343101
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Aquaporin-1 (AQP1) protein plays a crucial role in intracellular and extracellular water homeostasis and fluid transport in organs and tissues associated with diverse life activities and is extremely abundant in the kidney. Accurate detection of AQP1 in urine can be applied as screening of early-stage disease. Application of magnetic preconcentration and probe-based signal amplification strategy coupling to inductively coupled plasma mass spectrometry (ICP-MS) is a more accurate, sensitive and specific detection method for AQP1 in complex biological samples compared to conventional methods. Results: We described an element-labelling strategy based on magnetic preconcentration and probe-based immunoassay coupling to ICP-MS detection. The magnetic beads (MBs) modified with epoxy groups were capable of enriching AQP1 proteins and separating them from complex matrices. The probe constructed by conjugating anti-AQP1 antibody molecules on the surface of gold nanoparticles could specifically recognize AQP1 proteins attached on MBs and be analyzed by ICP-MS. The concentration of AQP1 protein could be precisely quantified and amplified by 14,000 times through the corresponding signal of Au atoms. This assay for AQP1 protein quantification achieved a detection limit down to 0.023 ng mL-1,-1 , a broad linear calibration curve between 0.3 ng mL-1-1 and 30 ng mL-1,-1 , as well as outstanding specificity. Significance: The proposed method was successfully applied to detect AQP1 protein in human urine samples, showing the potential for its applications concerning accurate AQP1 quantification. It can also screen a wide range of proteins provided the antibodies specific to these target proteins are available.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A method for direct, semi-quantitative analysis of gas phase samples using gas chromatography-inductively coupled plasma-mass spectrometry
    Carter, Kimberly E.
    Gerdes, Kirk
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2013, 85 : 34 - 44
  • [32] Quantitative analysis of major, minor and trace elements in fluid inclusions using laser ablation inductively coupled plasma mass spectrometry
    Gunther, D
    Audetat, A
    Frischknecht, R
    Heinrich, CA
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (04) : 263 - 270
  • [33] QUANTITATIVE-ANALYSIS OF TRACE-ELEMENTS IN CARBONATES USING LASER ABLATION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    PERKINS, WT
    FUGE, R
    PEARCE, NJG
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (06) : 445 - 449
  • [34] Validated measurements of the uranium isotopic signature in human urine samples using magnetic sector-field inductively coupled plasma mass spectrometry
    Tresl, I
    De Wannemacker, G
    Quétel, CR
    Petrov, I
    Vanhaecke, F
    Moens, L
    Taylor, PDP
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (02) : 581 - 586
  • [35] Determination of physiological platinum levels in human urine using magnetic sector field inductively coupled plasma mass spectrometry in combination with ultraviolet photolysis
    Begerow, J
    Turfeld, M
    Dunemann, L
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (10) : 913 - 916
  • [36] Elemental Analysis of Solid Food Materials Using a Reliable Laser Ablation Inductively Coupled Plasma Mass Spectrometry Method
    Zhou, Jianzong
    Guo, Wei
    Jin, Lanlan
    Hu, Shenghong
    Journal of Agricultural and Food Chemistry, 2022, 70 (15): : 4765 - 4773
  • [37] Detection of three tumor biomarkers in human lung cancer serum using single particle inductively coupled plasma mass spectrometry combined with magnetic immunoassay
    Cao, Yupin
    Feng, Jinsu
    Tang, Lifu
    Mo, Guichun
    Mo, Weiming
    Deng, Biyang
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 166
  • [38] Method Development for the Quantitative Analysis of Multivitamin Supplements by Laser Ablation–Inductively Coupled Plasma–Mass Spectrometry (LA-ICP-MS)
    Claudia Martinez Lopez
    Jake A. Carter
    Ruthmara Corzo
    Todor I. Todorov
    Food Analytical Methods, 2022, 15 : 3079 - 3091
  • [39] Quantitative analysis of volatile selenium metabolites in normal urine by headspace solid phase microextraction gas chromatography-inductively coupled plasma mass spectrometry
    Bueno, Maite
    Pannier, Florence
    TALANTA, 2009, 78 (03) : 759 - 763
  • [40] Quantitative Elemental Analysis of a Single Cell by Using Inductively Coupled Plasma-Mass Spectrometry in Fast Time-Resolved Analysis Mode
    Tanaka, Yu-ki
    Iida, Risako
    Takada, Shohei
    Kubota, Tetsuo
    Yamanaka, Michiko
    Sugiyama, Naoki
    Abdelnour, Yolande
    Ogra, Yasumitsu
    CHEMBIOCHEM, 2020, 21 (22) : 3266 - 3272