Weight-Based Standardized Sugammadex Dosing in Pediatrics: A Quality Improvement Initiative to Improve Compliance with Dosing Guidelines and Reduce Waste and Cost

被引:0
|
作者
Brown, Sydney E. S. [1 ,2 ]
Meyer, Michael [2 ]
Meyer, Andrea [2 ]
Cassidy, Ruth [1 ]
Zhao, Xinyi [1 ]
Wagner, Deborah [1 ]
Wetzel, Laura [2 ]
Colquhoun, Douglas A. [1 ]
机构
[1] Univ Michigan, Dept Anesthesiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Anesthesiol, Div Pediat Anesthesiol, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
INDUCED NEUROMUSCULAR BLOCKADE; REVERSAL; ROCURONIUM; MULTICENTER; ANESTHESIA; CHILDREN;
D O I
10.1155/2024/6049114
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study Objective. Sugammadex is a widely used neuromuscular blockade reversal agent. Cost concerns limit use in pediatric patients for, whom recommended doses are often far less than vial quantities. Therefore, we undertook a quality improvement initiative at a pediatric hospital in which sugammadex vials were fractionated. We hypothesized we would see a decrease in administered dose and waste and improved adherence with dosing guidelines. Methods. Sugammadex vials were fractionated into 25, 50, or 100 mg aliquots, which would be distributed to anesthesia staff by pharmacy staff in approximate 2 mg/kg of actual body weight doses (+/- 10%). We analyzed changes in sugammadex waste and dosing practices 1/1/2019 to 3/15/2023 pre/postintervention (4/1/2021). We gauged dose appropriateness using last train of four (TOF) prior to sugammadex administration. Results. 7,889 patients 2-17 years (4,771 with documented TOF), ASA 1-4 receiving general anesthesia with a steroidal NMB medication and sugammadex reversal. Pre- and postintervention mean doses were 2.5 mg/kg (SD: 1.2) and 2.4 mg/kg (SD: 0.96), respectively. A smaller proportion of cases received standard 2 or 4 mg/kg doses (pre: 77.6 vs. post: 66.7%). Mean waste per case declined from 4.2 mg/kg (SD: 4.1) to 0.22 mg/kg (SD: 0.38). Among cases with 0 or 1 measured twitches on TOF that should receive at least 4 mg/kg, fewer received at least 3.6 mg/kg (post: 56.7% vs. pre: 66.8%), and a greater proportion received less than 2.2 mg/kg (post: 27.4% vs. pre: 20.7%). Among cases that should have received at least 2 mg/kg by TOF, the proportion of patients receiving more than 3.6 mg/kg declined from 9.5% to 5.2%. Discussion. Fractionating sugammadex vials was associated with decreases in waste, but not dose, and significant underdosing was more likely to occur. While vial fractionation could enable increased access to sugammadex and other costly medications, it may introduce unintended consequences.
引用
收藏
页数:10
相关论文
共 41 条
  • [21] COMPUTERIZED PHYSICIAN ORDER ENTRY (CPOE) INCREASES WEIGHT-BASED DOSING COMPLIANCE WITH VANCOMYCIN PRESCRIBING IN THE EMERGENCY DEPARTMENT
    Rosini, Jamie
    Frankel, Kathryn Calmus
    Levine, Brian
    Jasani, Neil
    CRITICAL CARE MEDICINE, 2012, 40 (12) : U253 - U253
  • [22] Pembrolizumab Weight-Based Dosing: Conviction and Lacunae in Adopting a Cost-Saving Approach-A Survey Report
    Patel, Amol
    Akhade, Amol
    INDIAN JOURNAL OF MEDICAL AND PAEDIATRIC ONCOLOGY, 2022, : 298 - 303
  • [23] Weight-Based Aspirin Dosing May Further Reduce the Incidence of Venous Thromboembolism Following Primary Total Joint Arthroplasty
    Halbur, Christopher R.
    Gulbrandsen, Trevor R.
    West, Christopher R.
    Brown, Timothy S.
    Noiseux, Nicolas O.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (12): : 3986 - +
  • [24] Adopting Weight-Based Dosing With Pharmacy-Level Stewardship Strategies Could Reduce Cancer Drug Spending By Millions
    Bryant, Alex K.
    Chopra, Zoey
    Edwards, Donna M.
    Whalley, Adam S.
    Bazzell, Brian G.
    Moeller, Julie A.
    Kelley, Michael J.
    Fendrick, A. Mark
    Kerr, Eve A.
    Ramnath, Nithya
    Green, Michael D.
    Hofer, Timothy P.
    Strohbehn, Garth W.
    HEALTH AFFAIRS, 2023, 42 (07) : 946 - 955
  • [25] Improvement in Attaining Tacrolimus Trough Concentrations via the Implementation of a Strict Weight-Based Dosing Guideline Following Heart Transplantation
    Sylvia, Lynne
    Oster, Johannes
    Vest, Amanda
    DeNofrio, David
    JOURNAL OF CARDIAC FAILURE, 2019, 25 (08) : S66 - S66
  • [26] A projection image database to investigate factors affecting image quality in weight-based dosing: application to pediatric renal SPECT
    Li, Ye
    O'Reilly, Shannon
    Plyku, Donika
    Treves, S. Ted
    Du, Yong
    Fahey, Frederic
    Cao, Xinhua
    Jha, Abhinav K.
    Sgouros, George
    Bolch, Wesley E.
    Frey, Eric C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (14):
  • [27] FIXED-DOSE 4F-PCC IS SUPERIOR TO WEIGHT-BASED DOSING IN DELIVERY TIME AND COST WITH EQUAL REVERSAL
    Riha, Gordon
    Englehart, Michael
    Walton, Karin
    Saunders, Megan
    Carter, Benjamin
    Thompson, Simon
    CRITICAL CARE MEDICINE, 2023, 51 (01) : 362 - 362
  • [28] Safety, Efficacy, and Cost Saving Potential of Various Weight-Based Dosing for Thymoglobulin Induction Therapy in Kidney Transplant Recipients.
    Miller, R.
    Meadows, H.
    Strout, S.
    Veasey, T.
    Mardis, A.
    Fleming, J.
    Mardis, C.
    Pilch, N.
    Chavin, K.
    Taber, D.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2016, 16 : 616 - 616
  • [29] Effect of Fixed-Volume and Weight-Based Dosing Regimens on the Cost and Volume of Administered Iodinated Contrast Material at Abdominal CT
    Davenport, Matthew S.
    Parikh, Kushal R.
    Mayo-Smith, William W.
    Israel, Gag M.
    Brown, Richard K. J.
    Ellis, James H.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2017, 14 (03) : 359 - 370
  • [30] Minimal effective weight-based dosing of ondansetron to reduce hypotension in cesarean section under spinal anesthesia: a randomized controlled superiority trial
    Maliwan Oofuvong
    Thitikan Kunapaisal
    Orarat Karnjanawanichkul
    Nussara Dilokrattanaphijit
    Jaranya Leeratiwong
    BMC Anesthesiology, 18