Study of the out-of-field dose from an accelerator-based neutron source for boron neutron capture therapy

被引:1
|
作者
Verdera, Antonia [1 ]
Torres-Sanchez, Pablo [2 ]
Praena, Javier [1 ]
Porras, Ignacio [1 ]
机构
[1] Univ Granada, Dept Atom Mol & Nucl Phys, Granada, Spain
[2] Univ Valencia, Inst Fis Corpuscular, CSIC, Valencia, Spain
关键词
BNCT; Neutrons; Out-of-field; Equivalent dose; Ambient dose; CANCER; BNCT; RECURRENT; AMBIENT; BEAM; RISK; HEAD;
D O I
10.1016/j.apradiso.2024.111458
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
One important issue in Boron Neutron Capture Therapy is the delivered dose to the tissues outside the tumor. An international standard for light ion beam systems sets two recommended limits for out-of-field dose based on distance from the field edge: maximum absorbed dose from all radiation types shall not exceed 0.5 % of the maximum dose at distances 15 cm to 50 cm from the field edge. At distances > 50 cm from the field edge, the maximum absorbed dose shall not exceed 0.1 %. This paper is a continuation of our previous works focused on the design of an accelerator-based neutron source for BNCT. We already designed a novel Beam Shape Assembly which meets the IAEA criteria for BNCT treatments. Using this BSA, in the present work, we characterize by Monte Carlo simulations the dose outside the neutron field. The out-of-field dose has been assessed via estimates using the ambient and equivalent dose. Also the boron uptake in healthy tissues has been analyzed for the equivalent dose computation. It is concluded that our design for a future accelerator-based source for BNCT meets reasonably well the criteria defined from other forms of radiotherapy on both equivalent and effective dose outside the field.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Designing accelerator-based epithermal neutron beams for boron neutron capture therapy
    Bleuel, DL
    Donahue, RJ
    Ludewigt, BA
    Vujic, J
    MEDICAL PHYSICS, 1998, 25 (09) : 1725 - 1734
  • [22] Experimental verification of in-phantom calculations for an accelerator-based neutron source for boron neutron capture therapy
    Dobelbower, MC
    Vest, A
    Reed, MJ
    Blue, TE
    MEDICAL PHYSICS, 1999, 26 (03) : 376 - 380
  • [23] Treatment Planning for Accelerator-Based Boron Neutron Capture Therapy
    Herrera, Maria S.
    Gonzalez, Sara J.
    Minsky, Daniel M.
    Kreiner, Andres J.
    VIII LATIN AMERICAN SYMPOSIUM ON NUCLEAR PHYSICS AND APPLICATIONS, 2010, 1265 : 451 - 452
  • [24] Accelerator-based neutron source for the neutron-capture and fast neutron therapy at hospital
    Bayanov, BF
    Belov, VP
    Bender, ED
    Bokhovko, MV
    Dimov, GI
    Kononov, VN
    Kononov, OE
    Kuksanov, NK
    Palchikov, VE
    Pivovarov, VA
    Salimov, RA
    Silvestrov, GI
    Skrinsky, AN
    Soloviov, NA
    Taskaev, SY
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 413 (2-3): : 397 - 426
  • [25] The accelerator neutron source for boron neutron capture therapy
    Kasatov, D.
    Koshkarev, A.
    Kuznetsov, A.
    Makarov, A.
    Ostreinov, Yu
    Shchudlo, I.
    Sorokin, I.
    Sycheva, T.
    Taskaev, S.
    Zaidi, L.
    18TH INTERNATIONAL CONFERENCE PHYSICA.SPB, 2016, 769
  • [26] Design for an accelerator-based orthogonal epithermal neutron beam for boron neutron capture therapy
    Allen, DA
    Beynon, TD
    Green, S
    MEDICAL PHYSICS, 1999, 26 (01) : 71 - 76
  • [27] Neutron beam design and dosimetric evaluation for accelerator-based Boron Neutron Capture Therapy
    Bortolussi, S.
    Postuma, I.
    Protti, N.
    Fatemi, S.
    Magni, C.
    Gonzalez, S.
    Altieri, S.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1024 - S1024
  • [28] Accelerator-based source of epithermal neutrons for neutron capture therapy
    O. E. Kononov
    V. N. Kononov
    A. N. Solov’ev
    M. V. Bokhovko
    Atomic Energy, 2004, 97 (3) : 626 - 631
  • [29] Accelerator-based source of epithermal neutrons for neutron capture therapy
    Kononov, O.E.
    Kononov, V.N.
    Solov'ev, A.N.
    Bokhovko, M.V.
    Atomnaya Energiya, 2004, 97 (03): : 195 - 200
  • [30] Accelerator-based source of epithermal neutrons for neutron capture therapy
    Kononov O.E.
    Kononov V.N.
    Solov'ev A.N.
    Bokhovko M.V.
    Atomic Energy, 2004, 97 (3) : 626 - 631