Synthesising two-dimensional mammographic images using compressed sensing-reconstructed digital breast tomosynthesis images

被引:0
|
作者
Han, Seohee [1 ]
Yang, Hyesun [1 ]
Xu, Wenting [1 ]
Seo, Changwoo [1 ]
Cho, Hyosung [1 ]
Cha, Bo Kyung [2 ]
机构
[1] Yonsei Univ, Dept Radiat Convergence Engn, Wonju, South Korea
[2] Korea Electrotechnol Res Inst, Precis Med Device Res Ctr, Ansan, South Korea
来源
JOURNAL OF INSTRUMENTATION | 2024年 / 19卷 / 08期
关键词
Data processing methods; Medical-image reconstruction methods and algorithms; computer-aided diagnosis; X-ray mammography and scinto- and MRI-mammography;
D O I
10.1088/1748-0221/19/08/P08012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This study presents a method synthesizing a two-dimensional (2D) mammographic image of reasonable quality directly from a 3D digital breast tomosynthesis (DBT) image, reconstructed using an advanced compressed sensing (CS)-based algorithm. This approach aims to reduce the radiation dose required for complementary imaging technologies of digital mammography (DM) and DBT, eliminating the need for additional DM examinations. The method involves three main steps: projection data acquisition from a DBT system, CS-based DBT reconstruction, and synthesis of a 2D mammographic image from the reconstructed DBT image. To verify the efficacy of the proposed method, we conducted both a simulation and an experiment on a numerical breast and commercially available BR3D phantoms, respectively, prior to practical implementation in real-world DBT systems. Our simulation and experimental results indicated that the CS-based algorithm yielded markedly improved DBT reconstruction quality, preserving superior image homogeneity, better edge contour and sharpening, and fewer image artifacts. The measured contrast-to-noise ratio and structural similarity values of the CS-reconstructed DBT images were 10.31 and 0.78, respectively, which were approximately 2.2 and 3.1 times larger, respectively, than those of the filtered-backprojectionreconstructed DBT images in the simulation. The quality of the synthetic mammographic images using the CS-reconstructed DBT images was similar to that of conventional mammographic images obtained using a full dose, indicating the efficacy of the proposed method. Consequently, we successfully reconstructed DBT images of substantially high quality using the CS-based algorithm and synthesised 2D mammographic images of reasonable quality, potentially reducing the radiation dose to patients in the complementary imaging technologies of DM and DBT.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Two-Dimensional Breast Tomosynthesis with a Stationary Array of Thermionic Cathodes for Higher Resolution Images and Fast Acquisition
    Boone, J.
    Sisniega, A.
    Siewerdsen, J.
    Schwoebel, P.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [22] Comparison of breast percent density estimated from digital mammograms and central reconstructed tomosynthesis slice images
    Bakic, Predrag R.
    Kontos, Despina
    Troxel, Andrea B.
    Maidment, Andrew
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 674 - +
  • [23] Stereoscopic inspection of autopsied brain reconstructed from two-dimensional images
    Shintaku, Hiroshi
    Yamaguchi, Mari
    Toru, Shuta
    Kitagawa, Masanobu
    Hirokawa, Katsuiku
    Yokota, Takanori
    Uchihara, Toshiki
    [J]. BRAIN PATHOLOGY, 2019, 29 : 47 - 47
  • [24] Digital Breast Tomosynthesis with Synthesized Two-Dimensional Images versus Full-Field Digital Mammography for Population Screening: Outcomes from the Verona Screening Program
    Caumo, Francesca
    Zorzi, Manuel
    Brunelli, Silvia
    Romanucci, Giovanna
    Rella, Rossella
    Cugola, Loredana
    Bricolo, Paola
    Fedato, Chiara
    Montemezzi, Stefania
    Houssami, Nehmat
    [J]. RADIOLOGY, 2018, 287 (01) : 37 - 46
  • [25] Computerized detection of mass lesions in digital breast tomosynthesis images using two- and three dimensional radial gradient index segmentation
    Reiser, I
    Nishikawa, RM
    Giger, ML
    Wu, T
    Rafferty, E
    Moore, RH
    Kopans, DB
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2004, 3 (05) : 437 - 441
  • [26] Breast Tissue Classification in Digital Breast Tomosynthesis Images using Texture Features: A Feasibility Study
    Kontos, Despina
    Berger, Rachelle
    Bakic, Predrag R.
    Maidment, Andrew D. A.
    [J]. MEDICAL IMAGING 2009: COMPUTER-AIDED DIAGNOSIS, 2009, 7260
  • [27] RESTORATION OF BLURRED IMAGES BY TWO-DIMENSIONAL DIGITAL FILTERS.
    YAHAGI, TAKASHI
    NOGUCHI, KOKI
    [J]. 1600, (V 12):
  • [28] Evaluation of the image quality in digital breast tomosynthesis (DBT) employed with a compressed-sensing (CS)-based reconstruction algorithm by using the mammographic accreditation phantom
    Park, Yeonok
    Cho, Heemoon
    Je, Uikyu
    Cho, Hyosung
    Park, Chulkyu
    Lim, Hyunwoo
    Kim, Kyuseok
    Kim, Guna
    Park, Soyoung
    Woo, Taeho
    Choi, Sungil
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 804 : 72 - 78
  • [29] Digital Breast Tomosynthesis Complements Two-Dimensional Synthetic Mammography for Secondary Examination of Breast Cancer
    Nakajima, Eiji
    Tsunoda, Hiroko
    Ookura, Mariko
    Ban, Kanako
    Kawaguchi, Yuko
    Inagaki, Mami
    Ikeda, Norihiko
    Furukawa, Kinya
    Ishikawa, Takashi
    [J]. JOURNAL OF THE BELGIAN SOCIETY OF RADIOLOGY, 2021, 105 (01):
  • [30] Two-dimensional shift-and-add (SAA) algorithm for digital breast tomosynthesis reconstruction
    Chen, Y.
    Lo, J.
    Baker, J.
    Dobbins, J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2001 - 2001