Imaging Characteristics and Clinical Utility of Half-Dose versus Full-Dose Ultrawidefield Fundus Fluorescein Angiography

被引:0
|
作者
Szigiato, Andrei [1 ]
Sharma, Sumit [1 ]
Singh, Sandeep [1 ]
Baynes, Kim [1 ]
Lowder, Careen [1 ]
Kaiser, Peter K. [1 ]
Ehlers, Justis P. [1 ]
Srivastava, Sunil K. [1 ]
机构
[1] Cleveland Clin, Cole Eye Inst, 9500 Euclid Ave, Desk i32, Cleveland, OH 44195 USA
来源
OPHTHALMOLOGY RETINA | 2024年 / 8卷 / 10期
关键词
Design: Retrospective chart review; Ultrawide fundus fl uorescein angiography (UWFFA); Uveitis; Optos; Vascular leakage; Automated image analysis;
D O I
10.1016/j.oret.2024.04.024
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: In early 2022, a fluorescein shortage occurred in the United States. To meet the standard of care for patients who required ultrawidefield fundus fluorescein angiography (UWFFA), a regimen of half-dose (250 mg) sodium fluorescein (10%) was adopted instead of the full dose (500 mg) at the Cole Eye Institute (CEI). In this paper, we compare the image quality, clinical utility, and the side-effect profile of half-dose versus full-dose fluorescein in UWFFA for a cohort of stable patients. Participants: Patients with retinal vascular disease were included if they received half-dose and full-dose UWFFA (Optos California) within 6 months at the CEI. Eyes were excluded if they received intraocular injections, laser procedures, new immunosuppression, and worsened or improved inflammation on clinical examination. Methods: Quantitative assessment of vascular leakage was performed using a machine learning-enhanced automated segmentation platform. Leakage from late-phase UWFFA images was compared between half-dose and full-dose images. Qualitative assessment of image quality and relative vascular leakage was performed by 2 masked independent reviewers. Side effects after fluorescein administration were recorded for each patient. Main Outcome Measures: Masked leakage grading and automated leakage scores. Results: There were 52 eyes of 35 patients, 42 (81%) uveitic, 5 (9%) diabetic, and 4 (8%) normal controls. Patients had no change to their visual acuity (logarithm of the minimum angle of resolution mean, 0.3 +/- 0.6), anterior chamber and vitreous cell between UFFWA's. UWFFA images were deemed of equal quality and leakage by both masked reviewers (78%-87% agreement; K, 0.642). Automated leakage analysis showed mildly increased leakage in half-dose images overall (3.8% vs. 2.8%; P = 0.01) and in the macula (1.5% vs. 0.6%; P = 0.01). Side effects included nausea (half [n = 3, 9%] vs. full [n = 2, 6%]; P = 0.69) and urticaria (n = 0, 0% vs. n = Conclusions: In this cohort, half-dose UWFFA produced images that were of similar quality, clinical utility and with a similar side effect profile compared with full dose. Half-dose UWFFA can be used to accurately assess the retinal vasculature and could be used primarily as a method to save cost and prevent waste. Financial Disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article. Ophthalmology Retina 2024;8:981-986 (c) 2024 Published by Elsevier Inc. on behalf
引用
收藏
页码:981 / 986
页数:6
相关论文
共 50 条
  • [41] A comparative study between full-dose and half-dose intravesical immune bacille Calmette-Guerin injection in the management of superficial bladder cancer
    Kandeel, Wael
    Abdelal, Ashraf
    Elmohamady, Basheer N.
    Sebaey, Ahmed
    Elshaaer, Waleed
    Elbarky, Ehab
    Abdelwahab, Osama
    ARAB JOURNAL OF UROLOGY, 2015, 13 (04) : 233 - 237
  • [42] Half-dose abdominal CT with sinogram-affirmed iterative reconstruction technique in children - comparison with full-dose CT with filtered back projection
    Lee, Minwook
    Kim, Myung-Joon
    Han, Kyung Hwa
    Lee, Mi-Jung
    PEDIATRIC RADIOLOGY, 2015, 45 (02) : 188 - 193
  • [43] Dose Reduction in Abdominal Computed Tomography Intraindividual Comparison of Image Quality of Full-Dose Standard and Half-Dose Iterative Reconstructions With Dual-Source Computed Tomography
    May, Matthias S.
    Wuest, Wolfgang
    Brand, Michael
    Stahl, Christian
    Allmendinger, Thomas
    Schmidt, Bernhard
    Uder, Michael
    Lell, Michael M.
    INVESTIGATIVE RADIOLOGY, 2011, 46 (07) : 465 - 470
  • [44] Total-body PET/CT using half-dose FDG and compared with conventional PET/CT using full-dose FDG in lung cancer
    Tan, Hui
    Sui, Xiuli
    Yin, Hongyan
    Yu, Haojun
    Gu, Yusen
    Chen, Shuguang
    Hu, Pengcheng
    Mao, Wujian
    Shi, Hongcheng
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (06) : 1966 - 1975
  • [45] 3D PET/CT 82Rb PET myocardial blood flow quantification: comparison of half-dose and full-dose protocols
    Martin Lyngby Lassen
    Osamu Manabe
    Yuka Otaki
    Evann Eisenberg
    Phi T. Huynh
    Frances Wang
    Daniel S. Berman
    Piotr J. Slomka
    European Journal of Nuclear Medicine and Molecular Imaging, 2020, 47 : 3084 - 3093
  • [46] 3D PET/CT 82Rb PET myocardial blood flow quantification: comparison of half-dose and full-dose protocols
    Lassen, Martin Lyngby
    Manabe, Osamu
    Otaki, Yuka
    Eisenberg, Evann
    Huynh, Phi T.
    Wang, Frances
    Berman, Daniel S.
    Slomka, Piotr J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (13) : 3084 - 3093
  • [47] Total-body PET/CT using half-dose FDG and compared with conventional PET/CT using full-dose FDG in lung cancer
    Hui Tan
    Xiuli Sui
    Hongyan Yin
    Haojun Yu
    Yusen Gu
    Shuguang Chen
    Pengcheng Hu
    Wujian Mao
    Hongcheng Shi
    European Journal of Nuclear Medicine and Molecular Imaging, 2021, 48 : 1966 - 1975
  • [48] Half-Dose Photodynamic Therapy Targeting the Leakage Point on the Fluorescein Angiography in Acute Central Serous Chorioretinopathy: A Pilot Study
    Kim, Kyu Seop
    Lee, Won Ki
    Lee, Seung Bum
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (02) : 366 - 373
  • [49] Plasma aprotinin concentrations during cardiac surgery: Full-versus half-dose regimens
    Beath, SM
    Nuttall, GA
    Fass, DN
    Oliver, WC
    Ereth, MH
    Oyen, LJ
    ANESTHESIA AND ANALGESIA, 2000, 91 (02): : 257 - 264
  • [50] Intraindividual Comparison of Diagnostic Performance in Patients With Hepatic Metastasis of Full-Dose Standard and Half-Dose Iterative Reconstructions With Dual-Source Abdominal Computed Tomography
    Park, Mina
    Chung, Yong Eun
    Lee, Hye Sun
    Choi, Jin-Young
    Park, Mi-Suk
    Kim, Myeong-Jin
    Kim, Ki Whang
    INVESTIGATIVE RADIOLOGY, 2014, 49 (04) : 195 - 200