Accuracy of Instrumented Mouthguards During Direct Jaw Impacts Seen in Boxing

被引:0
|
作者
Venkatraman, Jay [1 ]
Abrams, Mitchell Z. [2 ]
Sherman, Donald [1 ]
Ortiz-Paparoni, Maria [2 ]
Bercaw, Jefferson R. [2 ]
Macdonald, Robert E. [1 ]
Kait, Jason [2 ]
Dimbath, Elizabeth [2 ]
Pang, Derek [2 ]
Gray, Alexandra [2 ]
Luck, Jason F. [2 ]
Bass, Cameron R. [1 ,2 ]
Bir, Cynthia A. [1 ]
机构
[1] Wayne State Univ, Dept Biomed Engn, Detroit, MI 48201 USA
[2] Duke Univ, Dept Biomed Engn, Durham, NC USA
关键词
Instrumented mouthguards; Post-mortem human subjects; Boxing punches; HEAD IMPACTS; FOOTBALL;
D O I
10.1007/s10439-024-03586-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeMeasuring head kinematics data is important to understand and develop methods and standards to mitigate head injuries in contact sports. Instrumented mouthguards (iMGs) have been developed to address coupling issues with previous sensors. Although validated with anthropomorphic test devices (ATDs), there is limited post-mortem human subjects (PMHS) data which provides more accurate soft tissue responses. This study evaluated two iMGs (Prevent Biometrics (PRE) and Diversified Technical Systems (DTS) in response to direct jaw impacts.MethodsThree unembalmed male cadaver heads were properly fitted with two different boil-and-bite iMGs and impacted with hook (4 m/s) and uppercut (3 m/s) punches. A reference sensor (REF) was rigidly attached to the base of the skull, impact kinematics were transformed to the head center of gravity and linear and angular kinematic data were compared to the iMGs including Peak Linear Acceleration, Peak Angular Acceleration, Peak Angular Velocity, Head Injury Criterion (HIC), HIC duration, and Brain Injury Criterion.ResultsCompared to the REF sensor, the PRE iMG underpredicted most of the kinematic data with slopes of the validation regression line between 0.72 and 1.04 and the DTS overpredicted all the kinematic data with slopes of the regression line between 1.4 and 8.7.ConclusionWhile the PRE iMG was closer to the REF sensor compared to the DTS iMG, the results did not support the previous findings reported with use of ATDs. Hence, our study highlights the benefits of using PMHS for validating the accuracy of iMGs since they closely mimic the human body compared to any ATD's mandible.
引用
收藏
页码:3219 / 3227
页数:9
相关论文
共 50 条
  • [31] Relative accuracy of HWRF reanalysis and a parametric wind model during the landfall of Hurricane Florence and the impacts on storm surge simulations
    Rahman, Md Arifur
    Zhang, Yu
    Lu, Lixin
    Moghimi, Saeed
    Hu, Kelin
    Abdolali, Ali
    NATURAL HAZARDS, 2023, 116 (01) : 869 - 904
  • [32] Direct and indirect photochemical impacts on the trace gases observed during the solar eclipse over a tropical rural location
    Jain, Chaithanya D.
    Ratnam, M. Venkat
    Madhavan, B. L.
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2020, 211
  • [33] Direct and indirect photochemical impacts on the trace gases observed during the solar eclipse over a tropical rural location
    Jain, Chaithanya D.
    Ratnam, M. Venkat
    Madhavan, B. L.
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2020, 211
  • [34] EFFECTS OF ERRORS IN FITTING UP BUTT JOINTS WITH BOTH EDGES BEVELLED ON THE ACCURACY OF DIRECT FOLLOWING DURING WELDING
    TIMCHENKO, VA
    CHVERTKO, AI
    AUTOMATIC WELDING USSR, 1981, 34 (09): : 42 - 45
  • [35] Improved accuracy of biomechanical motion data obtained during impacts using a time-frequency low-pass filter\
    Augustus, Simon
    Amca, Arif Mithat
    Hudson, Penny E.
    Smith, Neal
    JOURNAL OF BIOMECHANICS, 2020, 101
  • [36] Impacts of point spread function accuracy on patterning prediction and proximity effect correction in low-voltage electron-beam-direct-write lithography
    Liu, Chun-Hung
    Ng, Philip C. W.
    Shen, Yu-Tian
    Chien, Sheng-Wei
    Tsai, Kuen-Yu
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2013, 31 (02):
  • [37] Head Impacts during the Direct Frontal (Forehead) and Side (Temple) Collision - Human vs. Hybrid III Dummy
    Tomsovsky, Lubos
    Literova, Lucie
    Kubovy, Petr
    Lopot, Frantisek
    Havlicek, Martin
    Stocek, Ondrej
    Fara, Lukas
    Jezdik, Roman
    Purs, Hynek
    Tikkanen, Tommi
    Novak, Martin
    Jelen, Karel
    MANUFACTURING TECHNOLOGY, 2023, 23 (05): : 717 - 724
  • [38] Patterning accuracy estimation during stage acceleration in the electron beam direct writing system EX-8D
    Hattori, K
    Magoshi, S
    Ando, A
    Satoh, S
    Sunaoshi, H
    Suenaga, M
    Housai, H
    Hashimoto, S
    Wada, H
    Sugihara, K
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1996, 14 (06): : 3985 - 3989
  • [39] Correlating Accuracy of Bimanual Palpation vs Direct Mirror Visualisation to Assess Adenoidal Tissue Anatomy and Volume During Adenoidectomy
    Subramaniam, T.
    Barghouthi, T.
    Patil, N.
    Choo, M.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2013, 182 : 524 - 524
  • [40] When and Why Threats Go Undetected: Impacts of Event Rate and Shift Length on Threat Detection Accuracy During Airport Baggage Screening