Accuracy of Instrumented Mouthguards During Direct Jaw Impacts Seen in Boxing

被引:0
|
作者
Venkatraman, Jay [1 ]
Abrams, Mitchell Z. [2 ]
Sherman, Donald [1 ]
Ortiz-Paparoni, Maria [2 ]
Bercaw, Jefferson R. [2 ]
Macdonald, Robert E. [1 ]
Kait, Jason [2 ]
Dimbath, Elizabeth [2 ]
Pang, Derek [2 ]
Gray, Alexandra [2 ]
Luck, Jason F. [2 ]
Bass, Cameron R. [1 ,2 ]
Bir, Cynthia A. [1 ]
机构
[1] Wayne State Univ, Dept Biomed Engn, Detroit, MI 48201 USA
[2] Duke Univ, Dept Biomed Engn, Durham, NC USA
关键词
Instrumented mouthguards; Post-mortem human subjects; Boxing punches; HEAD IMPACTS; FOOTBALL;
D O I
10.1007/s10439-024-03586-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeMeasuring head kinematics data is important to understand and develop methods and standards to mitigate head injuries in contact sports. Instrumented mouthguards (iMGs) have been developed to address coupling issues with previous sensors. Although validated with anthropomorphic test devices (ATDs), there is limited post-mortem human subjects (PMHS) data which provides more accurate soft tissue responses. This study evaluated two iMGs (Prevent Biometrics (PRE) and Diversified Technical Systems (DTS) in response to direct jaw impacts.MethodsThree unembalmed male cadaver heads were properly fitted with two different boil-and-bite iMGs and impacted with hook (4 m/s) and uppercut (3 m/s) punches. A reference sensor (REF) was rigidly attached to the base of the skull, impact kinematics were transformed to the head center of gravity and linear and angular kinematic data were compared to the iMGs including Peak Linear Acceleration, Peak Angular Acceleration, Peak Angular Velocity, Head Injury Criterion (HIC), HIC duration, and Brain Injury Criterion.ResultsCompared to the REF sensor, the PRE iMG underpredicted most of the kinematic data with slopes of the validation regression line between 0.72 and 1.04 and the DTS overpredicted all the kinematic data with slopes of the regression line between 1.4 and 8.7.ConclusionWhile the PRE iMG was closer to the REF sensor compared to the DTS iMG, the results did not support the previous findings reported with use of ATDs. Hence, our study highlights the benefits of using PMHS for validating the accuracy of iMGs since they closely mimic the human body compared to any ATD's mandible.
引用
收藏
页码:3219 / 3227
页数:9
相关论文
共 50 条
  • [1] Measurement of Head Kinematics Using Instrumented Mouthguards During Introductory Boxing Courses in US Military Academy Cadets
    Fetchko, Travis J.
    Hart, Gerald J.
    Aderman, Michael J.
    Ross, Jeremy D.
    Malvasi, Steven R.
    Roach, Megan H.
    Cameron, Kenneth L.
    Rooks, Tyler F.
    MILITARY MEDICINE, 2023, 188 : 584 - 589
  • [2] Detecting and Salvaging Head Impacts with Decoupling Artifacts from Instrumented Mouthguards
    Gellner, Ryan
    Begonia, Mark T.
    Wood, Matthew
    Rockwell, Lewis
    Geiman, Taylor
    Jung, Caitlyn
    Gellner, Blake
    Macmartin, Allison
    Manlapit, Sophia
    Rowson, Steve
    ANNALS OF BIOMEDICAL ENGINEERING, 2025, : 1095 - 1112
  • [3] Validation and Comparison of Instrumented Mouthguards for Measuring Head Kinematics and Assessing Brain Deformation in Football Impacts
    Liu, Yuzhe
    Domel, August G.
    Yousefsani, Seyed Abdolmajid
    Kondic, Jovana
    Grant, Gerald
    Zeineh, Michael
    Camarillo, David B.
    ANNALS OF BIOMEDICAL ENGINEERING, 2020, 48 (11) : 2580 - 2598
  • [4] Validation and Comparison of Instrumented Mouthguards for Measuring Head Kinematics and Assessing Brain Deformation in Football Impacts
    Yuzhe Liu
    August G. Domel
    Seyed Abdolmajid Yousefsani
    Jovana Kondic
    Gerald Grant
    Michael Zeineh
    David B. Camarillo
    Annals of Biomedical Engineering, 2020, 48 : 2580 - 2598
  • [5] Correction to: Validation and Comparison of Instrumented Mouthguards for Measuring Head Kinematics and Assessing Brain Deformation in Football Impacts
    Yuzhe Liu
    August G. Domel
    Seyed Abdolmajid Yousefsani
    Jovana Kondic
    Gerald Grant
    Michael Zeineh
    David B. Camarillo
    Annals of Biomedical Engineering, 2021, 49 : 1119 - 1120
  • [6] Choosing Optimal Cutoff Frequencies for Filtering Linear Acceleration and Angular Velocity Signals Associated with Head Impacts Measured by Instrumented Mouthguards
    Gellner, Ryan
    Begonia, Mark
    Rowson, Steve
    ANNALS OF BIOMEDICAL ENGINEERING, 2024, 52 (05) : 1415 - 1424
  • [7] Choosing Optimal Cutoff Frequencies for Filtering Linear Acceleration and Angular Velocity Signals Associated with Head Impacts Measured by Instrumented Mouthguards
    Ryan Gellner
    Mark Begonia
    Steve Rowson
    Annals of Biomedical Engineering, 2024, 52 : 1415 - 1424
  • [8] Validation and Comparison of Instrumented Mouthguards for Measuring Head Kinematics and Assessing Brain Deformation in Football Impacts (vol 48, pg 2580, 2020)
    Liu, Yuzhe
    Domel, August G.
    Yousefsani, Seyed Abdolmajid
    Kondic, Jovana
    Grant, Gerald
    Zeineh, Michael
    Camarillo, David B.
    ANNALS OF BIOMEDICAL ENGINEERING, 2021, 49 (03) : 1119 - 1120
  • [9] Direct Measurement of Punch Force During Six Professional Boxing Matches
    Pierce, John D., Jr.
    Reinbold, Kirk A.
    Lyngard, Barry C.
    Goldman, Robert J.
    Pastore, Christopher M.
    JOURNAL OF QUANTITATIVE ANALYSIS IN SPORTS, 2006, 2 (02)
  • [10] Endodontic sequelae associated with repetitive impacts to the dentofacial region during boxing activities
    McCarthy, Sally
    Gulabivala, Kishor
    St. George, Geoffrey
    Harvey, Simon
    Ng, Yuan-Ling
    INTERNATIONAL ENDODONTIC JOURNAL, 2024, 57 (10) : 1380 - 1394