Evaluation of the measurement uncertainty during the calibration of metal reference gauges of the 2 nd category

被引:0
|
作者
Novoselov, O. [1 ]
机构
[1] Kharkiv Natl Univ Radio Elect, Nauky Ave 14, UA-61166 Kharkiv, Ukraine
来源
关键词
measurement uncertainty; working measurement standard; calibration method; metal reference gauge; metrological traceability;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The paper considers problematic issues related to ensuring the uniformity of measurements in the field of legal metrology, namely, during the calibration of working measurement standards used for verification of legally regulated measuring instruments. One of the conditions for ensuring the uniformity of measurements is the compliance of any measuring instrument with the requirements that are prescribed in its technical specification, where standardized metrological characteristics are indicated, which allows us to conclude about the suitability of the instrument for measurements in a known range and with a known accuracy. The procedure for verification of legally regulated measuring instruments establishes a ratio between the expanded measurement uncertainty provided for by the measurement standard and the maximum permissible error of the measuring instruments of no more than one to three. Determining such a ratio is an example of indirect accounting for the measurement uncertainty. The reliability of the assessment of the compliance of a working measurement standard with metrological requirements, which are regulated by the technical specification, depends on the correctness of the procedures for evaluating the measurement uncertainty during calibrations. The paper indicates the problems of updating the existing regulatory framework for the calibration of measuring instruments using reference gauges as an example and ensuring metrological traceability of the results of the calibration of the liquid volume measuring equipment. Attention was drawn to the need to apply in Ukraine the international practice of the standardization of calibration techniques and methods of uncertainty evaluation to ensure the uniformity of measurements. A procedure for evaluating the measurement uncertainty during the calibration of the reference 2 nd-grade gauge by the volumetric method, which is used as a working measurement standard when verifying legally regulated measuring instruments - fuel dispensers for refuelling cars - is proposed.
引用
收藏
页码:22 / 29
页数:8
相关论文
共 50 条
  • [41] Quantitative Measurement of Thermal Conductivity by SThM Technique: Measurements, Calibration Protocols and Uncertainty Evaluation
    Fleurence, Nolwenn
    Demeyer, Severine
    Allard, Alexandre
    Douri, Sarah
    Hay, Bruno
    NANOMATERIALS, 2023, 13 (17)
  • [42] Evaluation of Measurement Uncertainty for the Wave Buoy Calibration Device Using a Vertical Lifting Method
    Huang, Yafei
    Zhao, Donglei
    Gao, Chenhao
    Yan, Tian
    He, Lijun
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2025, 13 (03)
  • [43] Evaluation of the uncertainty component due to resistance measurement in the calibration of PRTs at the Al freezing point
    Yamazawa, K
    Harada, K
    Arai, M
    SICE 2002: PROCEEDINGS OF THE 41ST SICE ANNUAL CONFERENCE, VOLS 1-5, 2002, : 2444 - 2447
  • [44] Measurement uncertainty evaluation by kurtosis method at calibration of electrical resistance standards using a comparator
    Zakharov, I
    Botsiura, O.
    Semenikhin, V
    UKRAINIAN METROLOGICAL JOURNAL, 2020, (01): : 12 - 16
  • [45] 2nd EURACHEM Workshop on Measurement Uncertainty in Chemical Analysis
    Wolfhard Wegscheider
    Accreditation and Quality Assurance, 1998, 3 : 90 - 90
  • [46] 2nd GMA Conference:: Practical determination of measurement uncertainty
    Bachmair, H
    Sommer, KD
    TM-TECHNISCHES MESSEN, 2005, 72 (05) : 255 - 257
  • [47] 2nd EURACHEM Workshop on Measurement Uncertainty in Chemical Analysis
    Wegscheider, W
    ACCREDITATION AND QUALITY ASSURANCE, 1998, 3 (03) : 90 - 90
  • [48] Calibration and evaluation of routine methods by serum certified reference material for aldosterone measurement in blood
    Nishikawa, Tetsuo
    Omura, Masao
    Kawaguchi, Migaku
    Takatsu, Akiko
    Satoh, Fumitoshi
    Ito, Sadayoshi
    Kurihara, Isao
    Itoh, Hiroshi
    Yanase, Toshihiko
    Shibata, Hirotaka
    Oki, Yutaka
    Naruse, Mitsuhide
    Sakurai, Keiko
    Sasamoto, Hidehiko
    Kuwa, Katsuhiko
    ENDOCRINE JOURNAL, 2016, 63 (12) : 1065 - 1080
  • [49] Uncertainty evaluation in normalization of isotope delta measurement results against international reference materials
    Meija, Juris
    Chartrand, Michelle M. G.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (03) : 1061 - 1069
  • [50] Uncertainty evaluation in normalization of isotope delta measurement results against international reference materials
    Juris Meija
    Michelle M. G. Chartrand
    Analytical and Bioanalytical Chemistry, 2018, 410 : 1061 - 1069