An innovative UPLC-MS/MS method for the quantitation and pharmacokinetics of eupafolin in rat plasma

被引:0
|
作者
Xia, Mengming [1 ]
Ma, Shunjun [2 ]
Wang, Ying [1 ]
Chen, Dizhong [2 ]
Jiang, Lai [2 ]
Wen, Congcong [2 ]
Wu, Guangliang [1 ]
Wang, Xianqin [3 ]
机构
[1] Ningbo Univ, Affiliated Lihuili Hosp, Dept Pharm, Ningbo, Zhejiang, Peoples R China
[2] Wenzhou Med Univ, Lab Anim Ctr, Wenzhou, Peoples R China
[3] Wenzhou Med Univ, Sch Pharmaceut Sci, Wenzhou, Zhejiang, Peoples R China
关键词
UPLC-MS/MS; Eupafolin; Rat; Bioavailability; Pharmacokinetics;
D O I
10.1016/j.jchromb.2024.124272
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this experiment, a rapid and highly sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) technology was established and validated for the quantitation and pharmacokinetic analysis of eupafolin in rat plasma, utilizing licochalcone B as internal standard (IS). After liquid-liquid extraction of the analyte samples by ethyl acetate, chromatographic separation was achieved using a UPLC HSS T3 column under gradient elution conditions, with the mobile phase consisting of acetonitrile and water (with 0.1 % formic acid). Eupafolin was quantified by multiple reaction monitoring (MRM) in electrospray positive-ion mode (ESI+), employing the mass transition m/z 315.2 -> 300.3 for eupafolin and m/z 285.4 -> 270.3 for IS. Eupafolin demonstrated excellent linear relationship (r > 0.99) over the concentration range of 1.25-1250 ng/ mL, with the lower limit of quantification (LLOQ) of the UPLC-MS/MS assay determined as 1.25 ng/mL. Method validation followed the bioanalytical method validation criteria outlined by the FDA. The accuracy of eupafolin ranged from 86.7% to 111.2 %, and the precision was less than 12 %. The matrix effect was observed at 92.8 %-98.6 %, while the recoveries exceeded 83.2 %. The established UPLC-MS/MS assay was successfully employed for the pharmacokinetic evaluation of eupafolin in rats. The half-lives (t(1/2z)) were determined to be 1.4 +/- 0.4 h and 2.5 +/- 1.4 h for intravenous and oral administration, respectively. Notably, the bioavailability of eupafolin was relatively low (8.3 %). The optimized UPLC-MS/MS technology showed highly sensitive, selective, and effective, rendering it suitable for the pharmacokinetics of eupafolin in preclinical practice.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Pharmacokinetics of p-Coumaric Acid in Rat Plasma by UPLC-MS/MS
    Chen, Hao
    Wang, Hongzhe
    Liu, Huamin
    Xu, Xiaoxin
    Wen, Congcong
    Li, Xun
    LATIN AMERICAN JOURNAL OF PHARMACY, 2019, 38 (12): : 2428 - 2433
  • [22] Pharmacokinetics of Ziyuglycoside I and Ziyuglycoside II in Rat Plasma by UPLC-MS/MS
    Shen, Xiuwei
    Wang, Ziyue
    Li, Wenting
    Mei, Shenshen
    Ma, Shunjun
    Wang, Xianqin
    Wen, Congcong
    Chen, Fan
    Zheng, Guojun
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 2024
  • [23] Pharmacokinetics of Isocorynoxeine in Rat Plasma after Intraperitoneal Administration by UPLC-MS/MS
    Zhan, Haichao
    Wei, Zhen
    Ren, Ke
    Tong, Shuhua
    Wang, Xianqin
    Wu, Qing
    ACTA CHROMATOGRAPHICA, 2020, 32 (04) : 260 - 263
  • [24] Determination of Fargesin in Rat Plasma by UPLC-MS/MS and its Pharmacokinetics Application
    Wang, Haiyun
    Chen, Yichuan
    Wan, Jiafeng
    Xu, Jiali
    Mo, Jingjing
    Qian, Shuyi
    Zhou, Yunfang
    Wang, Xianqin
    Huang, Gang
    LATIN AMERICAN JOURNAL OF PHARMACY, 2018, 37 (09): : 1724 - 1729
  • [25] A simple method for the determination of Bosutinib in rat plasma by UPLC-MS/MS
    Xu, Yihua
    Huang, Xin-ce
    Dai, Shengjie
    Xiao, Yuwu
    Zhou, Meng-tao
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1004 : 93 - 97
  • [26] UPLC-MS/MS method for the quantification of ertugliflozin and sitagliptin in rat plasma
    Qiu, Xiangjun
    Xie, Saili
    Ye, Lei
    Xu, Ren-ai
    ANALYTICAL BIOCHEMISTRY, 2019, 567 : 112 - 116
  • [27] Validated UPLC-MS/MS Method for the Determination of Sunitinib in Rat Plasma
    Zhang, Yu
    Yuan, Rong-rong
    Zheng, Xiao-kang
    Hua, Chang-lin
    Wang, Ya-qiang
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 (06): : 1304 - 1308
  • [28] Development of an UPLC-MS/MS method for quantitative analysis of abexinostat levels in rat plasma and application of pharmacokinetics
    Yige Yu
    Jinyu Hu
    Xiaohai Chen
    Hua-lu Wu
    Anzhou Wang
    Congrong Tang
    BMC Chemistry, 18
  • [29] Development of an UPLC-MS/MS method for quantitative analysis of abexinostat levels in rat plasma and application of pharmacokinetics
    Yu, Yige
    Hu, Jinyu
    Chen, Xiaohai
    Wu, Hua-lu
    Wang, Anzhou
    Tang, Congrong
    BMC CHEMISTRY, 2024, 18 (01)
  • [30] A Quick Method for the Determination of Neomangiferin in Rat Plasma by UPLC-MS/MS
    Zhong, Youyan
    Wang, Qiong
    Wang, Haiyun
    Zhang, Qiang
    LATIN AMERICAN JOURNAL OF PHARMACY, 2019, 38 (06): : 1265 - 1270