Optimization study of strengthened T-shaped concrete-filled steel tubular (CFST) column-steel beam joint

被引:0
|
作者
Wang, Bo [1 ,2 ]
Gao, Xin [1 ]
Chen, Anying [1 ,2 ]
Yuan, Lizheng [1 ]
Wan, Haiying [1 ,2 ]
Wang, Zhaofeng
机构
[1] Hefei Univ Technol, Sch Civil Engn, Hefei 9, Anhui, Peoples R China
[2] Anhui Prov Key Lab Civil Engn Struct & Mat, Hefei 230009, Peoples R China
基金
中国国家自然科学基金;
关键词
Multi-chamber steel tubular concrete T-shaped; column; Joint region column wall reinforcement; Seismic performance; Optimization design; SEISMIC BEHAVIOR; STUB COLUMNS; CONNECTIONS;
D O I
10.1016/j.jcsr.2024.109020
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, a strengthened T-shaped concrete-filled steel tubular (CFST) column-steel beam joint is proposed. The joint is strengthened in the core region of the column wall as well as the beam, to avoid buckling of the column wall and outward displacement of the plastic hinge at the beam end. To study the damage modes and seismic performance of the joint, low-cycle loading experiments on two full-scale specimens of the joint were carried out. The results show that each specimen was damaged by plastic hinging of the steel beam flanges, the column walls did not buckle, and all had a good seismic performance. In addition, Abaqus finite element software was utilized to optimize the joints by analyzing the effects of changing the dimensions of the strengthened column and modifying the structure of the beam-column connection. Simulation results show that increasing the thickness and height of the strengthened column wall enhances the joint's load capacity, stiffness, and energy dissipation. it is recommended that the width-to-thickness ratio of the strengthened columns should be at most 0.08 and the beam-to-column height ratio should be kept at least 1.3. Additionally, two optimization methods, reducing the wall thickness of the steel corbel and weakening the steel beam flange, can effectively reduce weld tearing at the beam-to-column connections, while guaranteeing a good seismic performance. It is suggested that the slope of the steel corbel is not less than 1:6.25, and the weakening ratio of the steel beam flange is not greater than 0.267.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Calcuations for moment versus rotation relationship of the joint of beam and concrete-filled steel tubular column
    Qu, Hui
    Wang, Wen-Da
    Gongcheng Lixue/Engineering Mechanics, 2010, 27 (05): : 106 - 114
  • [42] NONLINEAR ANALYSIS OF NEW TYPE CONCRETE-FILLED STEEL TUBULAR COLUMN-BEAM JOINT
    Gu, S.
    Chu, Y. P.
    Chen, J.
    ADVANCES IN HETEROGENEOUS MATERIAL MECHANICS 2011, 2011, : 1019 - +
  • [43] MECHANICAL BEHAVIORS OF SIDE-PLATE JOINT BETWEEN WALLED CONCRETE-FILLED STEEL TUBULAR COLUMN AND H-SHAPED STEEL BEAM
    Huang, Yu-Qi
    Hao, Ji-Ping
    Bai, Rui
    Fan, Chun-Lei
    Xue, Qiang
    ADVANCED STEEL CONSTRUCTION, 2020, 16 (04): : 346 - 353
  • [44] Study on Plane-section Assumption of New Composite T-shaped Concrete-filled Steel Tubular Columns
    Huang, J.
    Dai, S. Q.
    Xie, J. Y.
    Wang, C.
    PROCEEDINGS OF THE 2017 6TH INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND SUSTAINABLE DEVELOPMENT (ICEESD 2017), 2017, 129 : 55 - 61
  • [45] Experimental and theoretical study on concrete-filled T-shaped steel tubular columns under uniaxial eccentric compression
    Lei, Min
    Li, Yuan-Qi
    Luo, Jin-Hui
    Li, Ying-Lei
    Wang, Peng
    ENGINEERING STRUCTURES, 2022, 265
  • [46] Behaviour of a concrete-filled steel tube beam-column T-joint
    Afefy, Hamdy Mohy El-Din
    Mahmoud, Mohamed Hussein
    Taher, Salah El-Din Fahmy
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2011, 164 (04) : 229 - 238
  • [47] Compressive behavior of T-shaped concrete filled steel tubular columns
    Yuanlong Yang
    Hua Yang
    Sumei Zhang
    International Journal of Steel Structures, 2010, 10 : 419 - 430
  • [48] Seismic Behaviors of Concrete-filled T-shaped Steel Tube Columns
    Wang, Yuyin
    Yang, Yuanlong
    Zhang, Sumei
    Liu, Jiepeng
    ADVANCES IN CONCRETE AND STRUCTURES, 2009, 400-402 : 677 - 683
  • [49] Seismic behaviors of concrete-filled T-shaped steel tube columns
    Wang, Yuyin
    Yang, Yuanlong
    Zhang, Sumei
    Liu, Jiepeng
    Key Engineering Materials, 2009, 400-402 : 677 - 683
  • [50] Orthogonal analysis on T-shaped concrete-filled steel tubular column seismic performance based on the finite element analysis results
    Cao, Bing
    Dai, Shaobin
    Huang, Jun
    CONSTRUCTION AND URBAN PLANNING, PTS 1-4, 2013, 671-674 : 523 - 528