A simple and efficient electrochemical sensor for folic acid determination on Ti(OH)4 4 modified carbon paste electrode

被引:0
|
作者
Shaila, G. S. [1 ]
Manjanna, J. [1 ]
Kumar, Mohan [2 ]
机构
[1] Rani Channamma Univ, Dept Chem, Belagavi 591156, Karnataka, India
[2] PES Inst Technol & Management, Dept Chem, Shivamogga 577204, Karnataka, India
关键词
Folic acid; Voltammetry; Modified carbon paste electrode; Ti(OH) 4; electrochemical sensor; ASCORBIC-ACID; NANOPARTICLES;
D O I
10.1016/j.inoche.2024.112912
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Folic acid (FA) has a crucial function in pregnant women and anemic patients. Having adequate FA prior to and during the gestation period can protect the brain of the child and spine from significant birth abnormalities. It reduces the risk of stroke, heart disease and some types of cancers, etc. Thus, FA is employed as a reliable biomarker in the early identification of various disorders. In the present study, we synthesized titanium tetra hydroxide [Ti(OH)4] 4 ] nanoparticles (NPs) by precipitation method with annealing at 100 degrees C, which is used to modify carbon paste electrode (Ti(OH)4 4 /MCPE). FA is detected here by voltammetry method using Ti(OH)4/ 4 / MCPE in the phosphate buffer of pH 6 and compared with bare and TiO2-400, 2-400, TiO2-600 2-600 and TiO2-800 2-800 degrees C NPs MCPE. Based on ac-impedance spectra, the conductivity of Ti(OH)4/MCPE 4 /MCPE was found to be higher, and consequently this electrode showed excellent sensitivity of 5.5 mu A mu M-- 1 cm- 2 . Lower detection limit (1.3 nM) was observed in the concentration range of 0.4-30 mu M by differential pulse voltammetry. The Ti(OH)4/MCPE 4 /MCPE was also effective for the determination of FA in real samples such as orange, banana, spinach and tablet. The electrochemical sensor investigated here showed excellent stability (92 %) up to 30 days.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Multi-walled carbon nanotube modified carbon paste electrode as an electrochemical sensor for the determination of epinephrine in the presence of ascorbic acid and uric acid
    Thomas, Tony
    Mascarenhas, Ronald J.
    Martis, Praveen
    Mekhalif, Zineb
    Swamy, B. E. Kumara
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (06): : 3294 - 3302
  • [42] SWCNT-modified carbon paste electrode as an electrochemical sensor for histamine determination in alcoholic beverages
    Zorica S. Stojanović
    Eda Mehmeti
    Kurt Kalcher
    Valéria Guzsvány
    Dalibor M. Stanković
    Food Analytical Methods, 2016, 9 : 2701 - 2710
  • [43] Selective voltammetric determination of norepinephrine in the presence of acetaminophen and folic acid at a modified carbon nanotube paste electrode
    Beitollahi, Hadi
    Sheikhshoaie, Iran
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 661 (02) : 336 - 342
  • [44] Electrochemical determination of captopril in the presence of acetaminophen, tryptophan, folic acid, and l-cysteine at the surface of modified carbon nanotube paste electrode
    Mazloum-Ardakani, Mohammad
    Sabaghian, Fariba
    Khoshroo, Alireza
    Abolhasani, Mahboobe
    Naeimi, Hossein
    IONICS, 2015, 21 (01) : 239 - 250
  • [45] Electrochemical determination of captopril in the presence of acetaminophen, tryptophan, folic acid, and l-cysteine at the surface of modified carbon nanotube paste electrode
    Mohammad Mazloum-Ardakani
    Fariba Sabaghian
    Alireza Khoshroo
    Mahboobe Abolhasani
    Hossein Naeimi
    Ionics, 2015, 21 : 239 - 250
  • [46] An electrochemical sensor for creatinine based on carbon nanotubes/folic acid/silver nanoparticles modified electrode
    Fekry, A. M.
    Abdel-Gawad, S. A.
    Tammam, R. H.
    Zayed, M. A.
    MEASUREMENT, 2020, 163
  • [47] Modified multiwalled carbon nanotubes paste electrode as a sensor for the electrocatalytic determination of N-acetylcysteine in the presence of high concentrations of folic acid
    Keyvanfard, Mohsen
    Ensafi, Ali A.
    Karimi-Maleh, Hassan
    Alizad, Khadijeh
    ANALYTICAL METHODS, 2012, 4 (10) : 3268 - 3274
  • [48] Electrochemical determination of hydrochlorothiazide and folic acid in real samples using a modified graphene oxide sheet paste electrode
    Beitollahi, Hadi
    Hamzavi, Mozhdeh
    Torkzadeh-Mahani, Masoud
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 52 : 297 - 305
  • [49] Sensitive electrochemical sensor for lamotrigine based on modified carbon paste electrode
    Maryam Haghighi
    Mehdi Rezaei
    Payam Sariaslani
    Sajad Moradi
    Mohsen Shahlaei
    Monatshefte für Chemie - Chemical Monthly, 2021, 152 : 903 - 914
  • [50] Electrochemical Behaviour of Norepinephrine in the Presence of Paracetamol and Folic Acid at Poly (Congo red) Modified Carbon Paste Electrode
    Kuskur, Chethan Maheshwarappa
    Swamy, Bahaddurghatta Eshwaraswamy Kumara
    Jayadevappa, Honnali
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (06): : 658 - 674