Exploration the feasibility and additional value of [18F]FDG/[68Ga]Ga-FAPI-04 dual-low-activity-tracer one-stop total-body PET imaging at 34 min post-injection of [68Ga]Ga-FAPI-04

被引:1
|
作者
Zheng, Zhe [1 ,2 ,3 ,4 ]
He, Yibo [1 ,2 ,3 ,4 ]
Mao, Wujian [1 ,2 ,3 ,4 ]
Yu, Haojun [1 ,2 ,3 ,4 ]
Wu, Ha [1 ,2 ,3 ,4 ]
Yang, Runjun [1 ,2 ,3 ,4 ]
Gao, Huaping [1 ,2 ,3 ,4 ]
Hu, Pengcheng [1 ,2 ,3 ,4 ]
Shi, Hongcheng [1 ,2 ,3 ,4 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Dept Nucl Med, Shanghai 200032, Peoples R China
[2] Shanghai Inst Med Imaging, Shanghai 200032, Peoples R China
[3] Fudan Univ, Nucl Med Inst, Shanghai 200032, Peoples R China
[4] Fudan Univ, Zhongshan Hosp, Canc Prevent & Treatment Ctr, Shanghai 200032, Peoples R China
关键词
2-[F-18]fluoro-2-deoxy-D-glucose; Fibroblast activation protein inhibitor; Positron emission tomography/Computed tomography; FAPI-weighted PET;
D O I
10.1007/s00259-024-06924-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To validate the feasibility of one-stop 2-[F-18]fluoro-2-deoxy-D-glucose ([F-18]FDG) and [Ga-68]Ga-fibroblast activation protein inhibitor-04 ([Ga-68]Ga-FAPI-04) dual-low-activity-tracer positron emission tomography/computed tomography (PET/CT) at 34 min post-injection of [Ga-68]Ga-FAPI-04 and explore its additional value. Methods: Thirty pairs of patients with suspected malignancies who underwent dual-tracer imaging were enrolled in this retrospective study. The images were reconstructed at 34-39 and 50-60 min after additional injection of [Ga-68]Ga-FAPI-04 (in one-stop FDG-FAPI PET/CT, named PETFDG, PETD34-39, and PETD50-60; in the 2-day protocol, named PETFDG', PETF34-39, and PETF50-60, respectively). Tumour-to-normal ratios (TNR) of lesions in PETFDG, PETD34-39, and PETD50-60 and TNR of lesions in PETF34-39 and PETF50-60 were evaluated separately. To evaluate the potential added value of one-stop FDG-FAPI PET/CT over the 2-day protocol, TNRs of PETFDG, PETD34-39, and PETD50-60 were compared with PETF34-39. The lesion detectability of the two imaging protocols was evaluated by chi-square test. Results: Comparing FAPI-weighted PET (PETD34-39 and PETD50-60) and single-tracer imaging (PETFDG) in one-stop FDG-FAPI PET/CT, TNRs of FAPI-weighted PET were higher than those of PETFDG. PETD34-39 and PETD50-60 showed similar performance in lesion detectability and TNRs (all P > 0.05). In the 2-day protocol, there are no statistically significant differences in TNRs of all lesions at PETF34-39 and PETF50-60. Comparing one-stop FDG-FAPI PET/CT with the 2-day protocol, TNRs of PETF34-39 were significantly higher than those of PETFDG but lower than those of PETD34-39 and PETD50-60. Lesion detectability in the one-stop FDG-FAPI PET/CT was higher than that in the 2-day protocol. The average radiation dose in one-stop FDG-FAPI PET/CT was significantly lower than that in the 2-day protocol (P<0.001). Conclusion: One-stop FDG-FAPI PET/CT at 34 min could provide sufficient information to meet clinical diagnosis and showed better lesion detectability than that in the 2-day protocol.
引用
收藏
页码:638 / 647
页数:10
相关论文
共 50 条
  • [41] [68Ga]Ga-FAPI-04 PET/CT imaging in signet-ring cell carcinoma of sigmoid colon
    Lilan Fu
    Kongzhen Hu
    Ganghua Tang
    Hubing Wu
    Wenlan Zhou
    European Journal of Nuclear Medicine and Molecular Imaging, 2021, 48 : 1690 - 1691
  • [42] A comparative study of [68Ga]Ga-FAPI-04 PET/MR and [18F]FDG PET/CT in the diagnostic accuracy and resectability prediction of ovarian cancer
    Xi, Yun
    Sun, Lili
    Che, Xiaoxia
    Huang, Xinyun
    Liu, Hua
    Wang, Qun
    Meng, Hongping
    Miao, Yuxin
    Qu, Qian
    Hai, Wangxi
    Li, Biao
    Feng, Weiwei
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (09) : 2885 - 2898
  • [43] [68Ga]Ga-FAPI-04 PET MRI/CT in the evaluation of gastric carcinomas compared with [18F]-FDG PET MRI/CT: a meta-analysis
    Wang, Yawen
    Luo, Wenhao
    Li, Ye
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2023, 28 (01)
  • [44] The feasibility of ultra-early and fast total‑body [68 Ga]Ga-FAPI-04 PET/CT scan
    Ruohua Chen
    Xinlan Yang
    Xiaofeng Yu
    Xiang Zhou
    Yee Ling Ng
    Yumei Chen
    Lianghua Li
    Yun Zhou
    Gang Huang
    Jianjun Liu
    European Journal of Nuclear Medicine and Molecular Imaging, 2023, 50 : 661 - 666
  • [45] [18F]FDG and[68Ga]Ga-DOTA-FAPI-04 PET/CT in the evaluation of tuberculous lesions
    Hao, Bing
    Wu, Xiurong
    Pang, Yizhen
    Sun, Long
    Wu, Hua
    Huang, Weipeng
    Chen, Haojun
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (02) : 651 - 652
  • [46] [18F]FDG and [68Ga]Ga-DOTA-FAPI-04 PET/CT in the evaluation of tuberculous lesions
    Bing Hao
    Xiurong Wu
    Yizhen Pang
    Long Sun
    Hua Wu
    Weipeng Huang
    Haojun Chen
    European Journal of Nuclear Medicine and Molecular Imaging, 2021, 48 : 651 - 652
  • [47] [68Ga]Ga-FAPI-04 PET MRI/CT in the evaluation of gastric carcinomas compared with [18F]-FDG PET MRI/CT: a meta-analysis
    Yawen Wang
    Wenhao Luo
    Ye Li
    European Journal of Medical Research, 28
  • [48] Comparison of [68Ga]Ga-DOTA-FAPI-04 and [18F]FDG Uptake in Esophageal Cancer
    Liu, Huipan
    Hu, Zhi
    Yang, Xiao
    Dai, Tianyang
    Chen, Yue
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [49] Multiple pseudotumors after ceramic-on-ceramic total hip arthroplasty revealed by [68Ga]Ga-FAPI-04 PET/CT
    Yiqun Wang
    Ruimin Wang
    Erpeng Qi
    Yinqiao Du
    Qingxiao Li
    Yanmei Wang
    Yonggang Zhou
    Jiahe Tian
    European Journal of Nuclear Medicine and Molecular Imaging, 2023, 50 : 626 - 627
  • [50] Head-to-head comparison of [68Ga]Ga-FAPI-04 PET and [18F]FDG PET in the detection of cancer recurrence: a systematic review and meta-analysis
    Wu, Qinchao
    Wang, Chen
    Huang, Chao
    Li, Dan
    TRANSLATIONAL CANCER RESEARCH, 2024, 13 (06) : 2779 - 2789