INVESTIGATION OF MULTIPHASE FLOW LEAK DETECTION IN PIPELINE USING TIME SERIES ANALYSIS TECHNIQUE

被引:0
|
作者
Barooah, Abinash [1 ]
Khan, Muhammad Saad [2 ]
Ferroudji, Hicham [2 ]
Rahman, Mohammad Azizur [2 ]
Hassan, Rashid [1 ]
Hassan, Ibrahim [3 ]
Sleiti, Ahmad K. [4 ]
Gomari, Sina Rezaei [5 ]
Hamilton, Matthew [6 ]
机构
[1] Texas A&M Univ, Dept Petr Engn, College Stn, TX 77840 USA
[2] Texas A&M Univ Qatar, Dept Petr Engn, Doha, Qatar
[3] Texas A&M Univ Qatar, Dept Mech Engn, Doha, Qatar
[4] Qatar Univ, Dept Mech Engn, Doha, Qatar
[5] Teesside Univ, Sch Comp Engn & Digital Technol, Middlesbrough, England
[6] Mem Univ, Dept Comp Sci Engn, St John, NL, Canada
关键词
Multiphase flow; Leak detection; Wavelet Analysis; Chronic small leak; False alarm;
D O I
暂无
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
Detecting chronic small leak sizes can be challenging because they may not produce significant or easily noticeable changes in flow rates or pressure differentials. Therefore, specialized techniques are often required to identify and locate chronic small leaks accurately in pipeline systems. The current study aims to address this gap by developing a method to identify multiphase flow leaks in pipelines using time series analysis techniques. An experimental flow loop apparatus, featuring a 2-inch (0.0508 m) diameter and extending 22.6 feet (6.9 m) in length, has been employed to carry out our experiments. The experiments encompass a range of liquid flow rates varying between 170 and 350 kg/min and gas flow rates ranging from 10 to 60 g/min. The system was equipped with three distinct leak opening diameters, measuring 1.8 mm, 2.5 mm, and 3 mm, each separated by 90 mm. Data collected from four dynamic pressure sensors was subjected to time series analysis such as wavelet transforms to detect and pinpoint the location of pipeline leaks. The obtained results indicate that dynamic pressure sensors are effective in detecting leak scenarios, as well as distinguishing between single and multiple leaks. However, for chronic small leaks, analyzing the standalone pressure response over time is generally not sufficient for detection. Time series analysis techniques play a crucial role in accurately identifying chronic small sized pipeline leaks. Discrete Wavelet Transform (DWT) was able to identify the point of leak opening and closing. Furthermore, DWT was able to reduce the false alarms for leak and no leak situations. This study introduces the application of time series analysis on dynamic pressure to detect chronic small sized leaks in multiphase flow pipelines. Additionally, it explores the capacity of wavelet analysis to minimize the occurrence of false alarms for leak and non-leak scenarios thereby addressing crucial safety, environmental, and economic concerns.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Numerical Leak Detection in a Pipeline Network of Complex Structure with Unsteady Flow
    K. R. Aida-zade
    E. R. Ashrafova
    Computational Mathematics and Mathematical Physics, 2017, 57 : 1919 - 1934
  • [32] A NON-INTRUSIVE PIPELINE LEAK DETECTION SERVICE USING PRESSURE WAVE ANALYSIS
    Jagannathan, Srinivasan
    Stewart, Neil
    Jack, Graham
    PROCEEDINGS OF THE 12TH INTERNATIONAL PIPELINE CONFERENCE, 2018, VOL 3, 2018,
  • [33] Curvature effect radius analysis in a two flow leak pipeline
    Sarmento L.R.B.
    Barbosa E.S.
    Leite B.E.
    Tavares D.P.S.A.
    Buriti C.J.
    Farias Neto S.R.
    Lima A.G.B.
    1600, Trans Tech Publications Ltd (366): : 118 - 125
  • [34] γ-CT Technique Used for Industrial Multiphase Flow Detection
    薛倩
    王化祥
    Journal of Measurement Science and Instrumentation, 2011, 2 (02) : 108 - 111
  • [35] A NEW APPROACH TO PIPELINE LEAK DETECTION USING ELECTROMAGNETIC SENSING
    Dawson, Chris
    Inkpen, Stuart
    Nolan, Chris
    Bonnell, David
    PROCEEDINGS OF THE 11TH INTERNATIONAL PIPELINE CONFERENCE, 2016, VOL 3, 2017,
  • [36] On Using Autoregressive Second Order Models for Pipeline Leak Detection
    Daneti, Marllene
    PROCEEDINGS OF THE 12TH WSEAS INTERNATIONAL CONFERENCE ON CIRCUITS: NEW ASPECTS OF CIRCUITS, 2008, : 102 - +
  • [37] PIPELINE LEAK DETECTION USING A MODERATE GAIN NONLINEAR OBSERVER
    Cunha, Sergio B.
    Baptista, Renan M.
    PROCEEDINGS OF THE ASME 2020 13TH INTERNATIONAL PIPELINE CONFERENCE (IPC2020), VOL 3, 2020,
  • [38] Leak Detection of Water Pipeline Using Wavelet Transform Method
    Tang, Xuhui
    Liu, Yongbo
    Zheng, Longjiang
    Ma, Changbao
    Wang, Hui
    2009 INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND INFORMATION APPLICATION TECHNOLOGY, VOL II, PROCEEDINGS, 2009, : 217 - 220
  • [39] Spatiotemporal sensing for pipeline leak detection using thermal video
    Sundaresan, Ganesh
    Kim, Seung-Yeon
    Lee, Jong-Jae
    Park, Ki-Tae
    Yun, Hae-Bum
    Structural Health Monitoring, 2014, 5 : 263 - 269
  • [40] Pipeline Leak Detection and Estimation Using Fuzzy PID Observer
    Jafari, Raheleh
    Razvarz, Sina
    Vargas-Jarillo, Cristobal
    Gegov, Alexander
    Arabikhan, Farzad
    ELECTRONICS, 2022, 11 (01)