Dynamic response characteristics of microchannel evaporator in a mechanically pumped two-phase loop under hypergravity environment

被引:0
|
作者
Wu, Suchen [1 ]
Yang, Ruixue [1 ]
Zhao, Taocheng [1 ]
Chen, Yongping [1 ,2 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Jiangsu, Peoples R China
[2] Suzhou Univ Sci & Technol, Key Lab Efficient Low Carbon Energy Convers & Util, Suzhou 215009, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Two-phase flow; Microchannel; Hypergravity; Startup; Operation; BOILING HEAT-TRANSFER; 2.168 MM TUBE; PRESSURE-DROP; BEHAVIOR; R134A;
D O I
10.1016/j.ijheatmasstransfer.2024.125999
中图分类号
O414.1 [热力学];
学科分类号
摘要
The unique hypergravity environment and severe heat-dissipation requirements of modern fighter aircrafts pose serious challenges to the potential utilization of mechanically pumped two-phase loops (MPTLs), which are an efficient cooling technology. The microchannel evaporator is a key component of the MPTL system, and understanding its startup and operation characteristics is of great significance for design and optimization. In this context, an experimental MPTL system is built and fixed on a rotating platform, which is designed to generate hypergravity ranging from 0 g0 0 to 15.0 g0 0 (g0 0 = 9.8 m & sdot;s-2). & sdot; s- 2 ). The dynamic-response characteristics of the temperature, pressure, and flow rates during the startup and operation of the microchannel evaporator under various hypergravity conditions are investigated. The results indicate that different startup modes, namely gradual startup under low hypergravity and overshoot startup under high hypergravity, are achieved on the micro- channel evaporator, even if the flow rate and heat flux are not changed, which is completely different from that under normal gravity. These two startup modes can be quantitatively recognized by two dimensionless numbers: the boiling number (Bo) Bo ) and Froude number (Fr). Fr ). A larger Bo or 1/Fr, , which corresponds to a larger heat flux or hypergravity; both conditions contribute to the startup mode of the microchannel evaporator shifting from gradual to overshoot startup. During the operation of a microchannel evaporator, the competition between the elevated saturation temperature of the fluid and the induced Coriolis and centrifugal forces caused by hyper- gravity determines the wall-temperature variation of the evaporator. The dynamic wall temperature decreases under hypergravity below 2.5 g0, 0 , is stable with small fluctuations under hypergravity from 4.7 g0 0 to 7.5 g0, 0 , and increases for hypergravity larger than 11.0 g0. 0 .
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Thermal performance of a two-phase loop thermosyphon with an additively manufactured evaporator
    Elkholy, Ahmed
    Unlusoy, Can
    Kempers, Roger
    APPLIED THERMAL ENGINEERING, 2022, 202
  • [42] The modelling of a two-phase capillary pumped loop for use in space
    Tjiptahardja, T
    Amidieu, M
    Moschetti, B
    HOUILLE BLANCHE-REVUE INTERNATIONALE DE L EAU, 1998, 53 (5-6): : 54 - 60
  • [43] SIMULATION AND VALIDATION OF A TWO-PHASE PUMPED LOOP COOLING SYSTEM
    Magee, Thomas C.
    Hines, Kristen M.
    Dumesh, Mike A.
    Meekins, Andrew D.
    Bridges, Michael M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2019, VOL 8, 2019,
  • [44] Flow boiling in parallel microchannels in a pumped two-phase loop: Flow visualization and thermal characteristics
    Kokate, Rohan
    Park, Chanwoo
    Mitsingas, Constandinos
    Schroen, Erik
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 155
  • [45] Design and performance of a mechanically pumped two-phase loop to support the evaporation-condensation experiments on the TZ1
    Wang, Z. R.
    Zhang, X. B.
    Wen, S. Z.
    Huang, Z. C.
    Mo, D. C.
    Xue, Y. Q.
    He, Z. H.
    CASE STUDIES IN THERMAL ENGINEERING, 2017, 10 : 650 - 655
  • [46] Development status of the mechanically pumped two-phase CO2 cooling loop for the AMS-2 TTCS
    Delil, AAM
    Woering, AA
    Verlaat, B
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM - STAIF 2003, 2003, 654 : 88 - 95
  • [47] Two-phase refrigerant flow in the evaporator of a stirling cooling system with a thermosyphon loop
    Celik, Serdar
    Ekren, Orhan
    EXPERIMENTAL HEAT TRANSFER, 2020, 33 (04) : 305 - 317
  • [48] Two-phase flow characteristics in Y-junction microchannel
    Liu, Zhaomiao
    Liu, Likun
    Shen, Feng
    Lixue Xuebao/Chinese Journal of Theoretical and Applied Mechanics, 2014, 46 (02): : 209 - 216
  • [49] Two-Phase Heat Transfer and Bubble Characteristics in a Microchannel Array
    Lagus, T. P.
    Kulacki, F. A.
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2012, 134 (07):
  • [50] Experimental and analytical study of a reversible two-phase capillary pumped loop
    Hustaix, H
    Maciaszek, T
    Puillet, C
    SIXTH EUROPEAN SYMPOSIUM ON SPACE ENVIRONMENTAL CONTROL SYSTEMS, VOLS 1 AND 2, 1997, 400 : 411 - 417