Unit Commitment With Frequency Stability Enhancement for an Isolated Power System

被引:0
|
作者
Wu, Jia-Jhang [1 ]
Chang, Gary W. [2 ]
Sinatra, Christian [2 ]
Tsai, Po-Yen [2 ]
机构
[1] Taiwan Power Co, Taipei 100208, Taiwan
[2] Natl Chung Cheng Univ, Dept Elect Engn, Chiayi 62102, Taiwan
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Dynamic regulation reserve; load frequency sensitivity index; mixed integer linear programming; unit commitment;
D O I
10.1109/ACCESS.2024.3421628
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents an efficient mixed-integer linear programming approach to unit commitment (UC) in isolated power systems while maintaining frequency stability under loss of generation contingencies. The dynamic frequency constraints considered are formulated using the center of inertia (COI) concept to determine the dominant parameters affecting system frequency response, specifically addressing the rate of change of frequency and the frequency nadir. Another significant contribution of this work is to propose a simple and computationally efficient method to obtain the lower bounds for the frequency constraints through the random sampling of generation unit combinations. Additionally, this paper introduces a load frequency sensitivity index-based method for determining the procured volume of dynamic regulation reserve from the ancillary service market. By incorporating these methods into the UC framework, the system can better adapt to system frequency dynamics. The proposed approach is validated using the benchmark system of Taiwan Power Company. Simulation results demonstrate the efficacy of the proposed methods in enhancing frequency stability during both low and high load demand days. Comparative analyses also highlight the benefits of Taipower's internally provided dynamic regulation reserves. These reserves are enforced through frequency constraints in the proposed UC model, resulting in increased online units and enhanced frequency nadir compared to the conventional UC method. External procurement of dynamic regulation reserves is more cost-effective and recommended during low load demand days.
引用
收藏
页码:91396 / 91409
页数:14
相关论文
共 50 条
  • [1] Frequency-Regulating Reserve Constrained Unit Commitment for an Isolated Power System
    Chang, Gary W.
    Chuang, Ching-Sheng
    Lu, Tai-Ken
    Wu, Ching-Chung
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (02) : 578 - 586
  • [2] Optimal power system unit commitment with guaranteed local stability
    Grote, Wolfgang
    Kastsian, Darya
    Moennigmann, Martin
    [J]. 2011 AMERICAN CONTROL CONFERENCE, 2011, : 4526 - 4531
  • [3] ANALYSIS OF FREQUENCY STABILITY IN ISOLATED POWER SYSTEM
    Azubalis, Mindaugas
    Jonaitis, Audrius
    [J]. ELECTRICAL AND CONTROL TECHNOLOGIES, 2011, : 359 - 362
  • [4] Conditions for Regional Frequency Stability in Power System Scheduling-Part II: Application to Unit Commitment
    Badesa, Luis
    Teng, Fei
    Strbac, Goran
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2021, 36 (06) : 5567 - 5577
  • [5] Determination of required instantaneous power reserve for power system inertia enhancement, based on the unit commitment
    Leiva, Daniel A.
    Mercado, Pedro E.
    Suvire, Gaston O.
    [J]. SUSTAINABLE ENERGY GRIDS & NETWORKS, 2023, 35
  • [6] Frequency control analysis based on unit commitment schemes with high wind power integration: A Spanish isolated power system case study
    Fernandez-Guillamon, Ana
    Ignacio Sarasua, Jose
    Chazarra, Manuel
    Vigueras-Rodriguez, Antonio
    Fernandez-Munoz, Daniel
    Molina-Garcia, Angel
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 121
  • [7] Unit Commitment for Isolated Microgrids Considering Frequency Control
    Farrokhabadi, Mostafa
    Canizares, Claudio A.
    Bhattacharya, Kankar
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2018, 9 (04) : 3270 - 3280
  • [8] Unit Commitment of Power System With High Proportion of Wind Power Considering Frequency Safety Constraints
    Lin H.
    Hou K.
    Chen L.
    Xia D.
    Min Y.
    Qin S.
    Zhang B.
    [J]. Chen, Lei (chenlei08@tsinghua.edu.cn), 1600, Power System Technology Press (45): : 1 - 9
  • [9] Robust Unit Commitment Including Frequency Stability Constraints
    Perez-Illanes, Felipe
    Alvarez-Miranda, Eduardo
    Rahmann, Claudia
    Campos-Valdes, Camilo
    [J]. ENERGIES, 2016, 9 (11)
  • [10] Reconfiguration of District Heating Network for Operational Flexibility Enhancement in Power System Unit Commitment
    Xue, Yixun
    Shahidehpour, Mohammad
    Pan, Zhaoguang
    Wang, Bin
    Zhou, Quan
    Guo, Qinglai
    Sun, Hongbin
    [J]. IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2021, 12 (02) : 1161 - 1173