Optimal high-pressure correlation for transcritical CO2 cycle in direct expansion solar assisted heat pumps

被引:2
|
作者
Reis, Humberto O. [1 ]
Paulino, Tiago F. [2 ,3 ]
Machado, Luiz [1 ]
Maia, Antonio A. T. [1 ]
Duarte, Willian M. [1 ]
机构
[1] Fed Univ Minas Gerais UFMG, Grad Program Mech Engn PPGMEC, Belo Horizonte, Brazil
[2] Fed Ctr Technol Educ Minas Gerais CEFET MG, Grad Program Mech Engn, Belo Horizonte, Brazil
[3] Fed Ctr Technol Educ Minas Gerais, Ctr Smart Energy Res CPEI, Belo Horizonte, Brazil
来源
关键词
Carbon dioxide; Heat pump; Solar assisted; Optimum high pressure; R744; CARBON-DIOXIDE; PERFORMANCE ANALYSIS; REJECTION PRESSURE; CO2; SYSTEM; OPTIMIZATION; EVAPORATOR; PARAMETERS; R1234YF; MODEL;
D O I
10.1016/j.jobe.2024.110616
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Heat demand may be met sustainably by a solar-assisted heat pump that CO2 as a refrigerant. This is made possible by the employment of an ecologically benign refrigerant and a renewable energy source that enhances system performance. At the ideal high pressure, the CO2 heat pump running in a transcritical cycle will function at its highest coefficient of performance (COP). In that way, this study aims to present correlations for calculating the optimum high pressure in a CO2 direct expansion solar assisted heat pump (DX-SAHP). In this study a mathematical model for compressor, solar evaporator and gas cooler was developed and validated experimentally. The mean difference between the mathematical model and experimental results are -3.9%. Two new equations are proposed to calculate the optimum high pressure in a CO2 DX-SAHP. The first one considered environment temperature, water outlet temperature and evaporating temperature, which are easy to measure. These facilities the use of correlation to control the heat pump. The second one considered environment temperature, water outlet temperature and solar radiation, which are more suitable for designing CO2 DX-SAHP. A data base with 100 optimum points was used to curve fitting. Another data base with 50 optimum points was used to compare the results obtained from curve fitting and correlations for the optimum high pressure available in the literature. The proposed correlations shown a maximum error lower than 10.2% despite of the correlations available in the literature from which the errors are about 30%.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] THERMODYNAMIC ANALYSIS AND EXPERIMENTAL RESEARCH OF TRANSCRITICAL CO2 CYCLE WITH INTERNAL HEAT EXCHANGER AND DUAL EXPANSION
    Wang, Z.
    Gong, Y.
    Wu, X. H.
    Zhang, W. H.
    Lu, Y. L.
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2013, 21 (01)
  • [32] Determination of the optimal discharge pressure of the transcritical CO2 heat pump cycles for heating and cooling performances based on new correlation
    Saeed Maddah
    Mohammad Reza Safaei
    Journal of Thermal Analysis and Calorimetry, 2021, 145 : 1537 - 1546
  • [33] Determination of the optimal discharge pressure of the transcritical CO2 heat pump cycles for heating and cooling performances based on new correlation
    Maddah, Saeed
    Safaei, Mohammad Reza
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 145 (03) : 1537 - 1546
  • [34] A study on the compressor frequency and optimal discharge pressure of the transcritical CO2 heat pump system
    Qin, Xiang
    Liu, Huadong
    Meng, Xiangrui
    Wei, Xinli
    Zhao, Linghua
    Yang, Lingxiao
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 99 : 101 - 113
  • [35] Optimal schemes and benefits of recovering waste heat from data center for district heating by CO2 transcritical heat pumps
    Li, Jian
    Yang, Zhen
    Li, Hailong
    Hu, Shuozhuo
    Duan, Yuanyuan
    Yan, Jinyue
    ENERGY CONVERSION AND MANAGEMENT, 2021, 245
  • [36] Experimental characterization of a transcritical CO2 direct expansion ground source heat pump for heating applications
    Bastani, Arash
    Eslami-Nejad, Parham
    Badache, Messaoud
    Alain Tuan Anh Nguyen
    ENERGY AND BUILDINGS, 2020, 212 (212)
  • [37] Dynamic modeling study for a solar evaporator with expansion valve assembly of a transcritical CO2 heat pump
    Faria, Ralney N.
    Nunes, Raphael O.
    Koury, Ricardo Nicolau N.
    Machado, Luiz
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 64 : 203 - 213
  • [38] The optimum high pressure for CO2 transcritical refrigeration systems with internal heat exchangers
    Chen, Y
    Gu, JJ
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (08): : 1238 - 1249
  • [39] Experimental performance analysis of a CO2 direct-expansion solar assisted heat pump water heater
    Duarte, Willian M.
    Rabelo, Sabrina N.
    Paulino, Tiago F.
    Pabon, Juan J. G.
    Machado, Luiz
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 125 : 52 - 63
  • [40] Gas engine-driven CO2 transcritical cycle heat
    Guan, HQ
    Ma, YT
    Liu, SC
    Yang, JL
    2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 223 - 228