Optimal high-pressure correlation for transcritical CO2 cycle in direct expansion solar assisted heat pumps

被引:2
|
作者
Reis, Humberto O. [1 ]
Paulino, Tiago F. [2 ,3 ]
Machado, Luiz [1 ]
Maia, Antonio A. T. [1 ]
Duarte, Willian M. [1 ]
机构
[1] Fed Univ Minas Gerais UFMG, Grad Program Mech Engn PPGMEC, Belo Horizonte, Brazil
[2] Fed Ctr Technol Educ Minas Gerais CEFET MG, Grad Program Mech Engn, Belo Horizonte, Brazil
[3] Fed Ctr Technol Educ Minas Gerais, Ctr Smart Energy Res CPEI, Belo Horizonte, Brazil
来源
关键词
Carbon dioxide; Heat pump; Solar assisted; Optimum high pressure; R744; CARBON-DIOXIDE; PERFORMANCE ANALYSIS; REJECTION PRESSURE; CO2; SYSTEM; OPTIMIZATION; EVAPORATOR; PARAMETERS; R1234YF; MODEL;
D O I
10.1016/j.jobe.2024.110616
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Heat demand may be met sustainably by a solar-assisted heat pump that CO2 as a refrigerant. This is made possible by the employment of an ecologically benign refrigerant and a renewable energy source that enhances system performance. At the ideal high pressure, the CO2 heat pump running in a transcritical cycle will function at its highest coefficient of performance (COP). In that way, this study aims to present correlations for calculating the optimum high pressure in a CO2 direct expansion solar assisted heat pump (DX-SAHP). In this study a mathematical model for compressor, solar evaporator and gas cooler was developed and validated experimentally. The mean difference between the mathematical model and experimental results are -3.9%. Two new equations are proposed to calculate the optimum high pressure in a CO2 DX-SAHP. The first one considered environment temperature, water outlet temperature and evaporating temperature, which are easy to measure. These facilities the use of correlation to control the heat pump. The second one considered environment temperature, water outlet temperature and solar radiation, which are more suitable for designing CO2 DX-SAHP. A data base with 100 optimum points was used to curve fitting. Another data base with 50 optimum points was used to compare the results obtained from curve fitting and correlations for the optimum high pressure available in the literature. The proposed correlations shown a maximum error lower than 10.2% despite of the correlations available in the literature from which the errors are about 30%.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Solar irradiation and refrigerant charge effects on performance of direct expansion solar assisted heat pumps using CO2 transcritical cycle
    Humia, Gleberson M.
    Machado, Luiz
    Paulino, Tiago de Freitas
    Maia, Antonio A. T.
    Duarte, Willian M.
    APPLIED THERMAL ENGINEERING, 2025, 267
  • [2] Minimizing COP loss from optimal high pressure correlation for transcritical CO2 cycle
    Yang, Liang
    Li, Hui
    Cal, Si-Wei
    Shao, Liang-Liang
    Zhang, Chun-Lu
    APPLIED THERMAL ENGINEERING, 2015, 89 : 656 - 662
  • [3] Constrained optimal high pressure equation of CO2 transcritical cycle
    Shao, Liang-Liang
    Zhang, Zi-Yang
    Zhang, Chun-Lu
    APPLIED THERMAL ENGINEERING, 2018, 128 : 173 - 178
  • [4] Optimal heat rejection pressure for transcritical CO2 refrigeration cycle with an expander
    Yang, Jun Lan
    Ma, Yi Tai
    Zhang, Jia Hui
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2016, 13 (02) : 208 - 212
  • [5] Simulation of the optimal heat rejection pressure for transcritical CO2 expander cycle
    Yang J.
    Ma Y.
    Li M.
    Tian H.
    Frontiers of Energy and Power Engineering in China, 2010, 4 (4): : 522 - 526
  • [6] Mass flow characteristics of CO2 operating in a transcritical cycle flowing through a needle expansion valve in a direct-expansion solar assisted heat pump
    Rabelo, Sabrina N.
    Paulino, Tiago F.
    Soares, Carla P. M.
    Duarte, Willian M.
    Machado, Luiz
    Nunes, Raphael O.
    JOURNAL OF BUILDING ENGINEERING, 2023, 67
  • [7] Vortex Tube Expansion Transcritical CO2 Heat Pump Cycle
    Liu Yingfu
    Geng Chunjing
    Jin Guangya
    DIGITAL MANUFACTURING & AUTOMATION III, PTS 1 AND 2, 2012, 190-191 : 1340 - +
  • [8] Difference analysis on optimal high pressure of transcritical CO2 cycle in different applications
    Liang, Xing-Yu
    He, Yu-Jia
    Cheng, Jia-Hao
    Shao, Liang-Liang
    Zhang, Chun-Lu
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 106 : 384 - 391
  • [9] OPTIMUM HIGH PRESSURE FOR TRANSCRITICAL CO2 HEAT PUMPS CONSIDERING ISENTROPIC EFFICIENCY AND GLIDING HEAT EXTRACTION
    Spindler, Klaus
    13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 63 - 70
  • [10] UTILIZATION OF EXPANSION WORK IN TRANSCRITICAL CO2 HEAT PUMPS IN COMBINED HEATING AND COOLING
    Stosic, Nikola
    Smith, Ian K.
    IMECE 2008: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2008, VOL 8, 2009, : 571 - 576