Non-contrast magnetic resonance evaluation of active multiple sclerosis lesions: Emerging role of quantitative synthetic magnetic resonance imaging

被引:1
|
作者
Girdhar, Sachin [1 ]
Nair, Sruthi S. [2 ]
Thomas, Bejoy [3 ]
Kesavadas, Chandrasekharan [3 ]
机构
[1] Command Hosp WC, Panchkula 134107, Haryana, India
[2] SCTIMST, Dept Neurol, Trivandrum, India
[3] SCTIMST, Dept Imaging Sci & Intervent Radiol, Trivandrum, India
来源
NEURORADIOLOGY JOURNAL | 2025年 / 38卷 / 02期
关键词
Synthetic MRI; quantitative MRI; multiple sclerosis; contrast enhancing; NEPHROGENIC SYSTEMIC FIBROSIS; DISEASE-MODIFYING THERAPIES; HIGH-RESOLUTION T-1; BRAIN; MRI; TIME; RECOMMENDATIONS; T1; T2;
D O I
10.1177/19714009241269541
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Purpose: The current study aims to explore the utility of novel synthetic MRI-derived quantitative parameters including myelin-correlated volume (MyC) in identifying active MS lesions without injecting gadolinium contrast. Methods: 43 MS patients underwent institutional MS protocol including 3D FLAIR and post-contrast 3D T1VIBE sequence on a 1.5 T MR Scanner in addition to synthetic MRI sequence. MS plaques were categorised into enhancing (C) and non-enhancing (N) lesions. They were also sub-categorised based on location into periventricular WM lesions (P), deep WM lesions (D), infratentorial lesions (I) and cortical-juxtacortical (C) lesions. ROIs were placed on Synthetic FLAIR images in MS lesions and quantitative parameters of R1, R2, PD and myelin-correlated volume (MyC) obtained. Sensitivity and specificity for various cut-off values to differentiate enhancing from non-enhancing multiple sclerosis lesions were calculated by performing ROC curve analysis and logistic regression analysis. Results: Contrast enhancing lesions demonstrated significantly higher mean R1, R2 values and lower mean PD values in comparison to non-enhancing lesions (p < 0.05) but with limited specificity. Region-wise analysis revealed high AUC values for mean R1 and R2 at cortical-juxtacortical lesions (p < 0.001) followed by periventricular lesions (p < 0.003) for differentiating enhancing from non-enhancing lesions with no significant contribution from MyC and PD values. Conclusion: Synthetic MRI-derived quantitative parameters of mean R1, R2, MyC and PD hold value in differentiating contrast enhancing and non-enhancing MS lesions without administering gadolinium-based contrast agent. However, the current study did not achieve significant specificity for establishing the same.
引用
收藏
页码:176 / 184
页数:9
相关论文
共 50 条
  • [21] Magnetic resonance imaging in multiple sclerosis
    Clanet, M
    Berry, I
    CURRENT OPINION IN NEUROLOGY, 1998, 11 (04) : 299 - 303
  • [22] Magnetic resonance imaging in multiple sclerosis
    Sailer, M
    Bodammer, N
    Miller, DH
    KLINISCHE NEUROPHYSIOLOGIE, 2000, 31 : S33 - S42
  • [23] Slowly expanding/evolving lesions as a magnetic resonance imaging marker of chronic active multiple sclerosis lesions
    Elliott, Colm
    Wolinsky, Jerry S.
    Hauser, Stephen L.
    Kappos, Ludwig
    Barkhof, Frederik
    Bernasconi, Corrado
    Wei, Wei
    Belachew, Shibeshih
    Arnold, Douglas L.
    MULTIPLE SCLEROSIS JOURNAL, 2019, 25 (14) : 1915 - 1925
  • [24] Quantitative susceptibility mapping of multiple sclerosis lesions in a longitudinal cohort using magnetic resonance imaging
    Subramanian, K.
    Utriainen, D.
    Ramasamy, D. P.
    Beaver, J.
    Sethi, S.
    Schweser, F.
    Fawaz, M.
    Hagemeier, J.
    Rajagovindan, R.
    Zivadinov, R.
    Haacke, E. M.
    MULTIPLE SCLEROSIS JOURNAL, 2016, 22 : 213 - 214
  • [25] Virtual non-contrast enhanced magnetic resonance imaging (VNC-MRI)
    Lindner, Thomas
    Debus, Hanna
    Fiehler, Jens
    MAGNETIC RESONANCE IMAGING, 2021, 81 : 67 - 74
  • [26] Non-contrast enhancement of brachial plexus magnetic resonance imaging with compressed sensing
    Pribowo, Muhammad Agus
    Harahap, Muhammad Irvanie Rama
    Fazharyasti, Vininta
    Dwihapsari, Yanurita
    Kartikasari, Yeti
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 165
  • [27] Role of non-contrast magnetic resonance imaging in pre-surgical evaluation of renal masses in renal impairment patients
    Zaytoun, Osama M.
    Darweesh, Reda M.
    Gaber, Salma A.
    Ibrahim, Rafik M.
    AFRICAN JOURNAL OF UROLOGY, 2021, 27 (01)
  • [28] Non-Contrast Magnetic Resonance Imaging of Isolated Superior Mesenteric Artery Dissection
    Uchida, Akiko
    Matsuura, Yunosuke
    Kuroiwa, Yasuyoshi
    Kaikita, Koichi
    CIRCULATION REPORTS, 2024, 6 (02) : 34 - 35
  • [29] Role of non-contrast magnetic resonance imaging in pre-surgical evaluation of renal masses in renal impairment patients
    Osama M. Zaytoun
    Reda M. Darweesh
    Salma A. Gaber
    Rafik M. Ibrahim
    African Journal of Urology, 2021, 27
  • [30] The Role of Advanced Magnetic Resonance Imaging Sequences in Multiple Sclerosis
    Siddiqui, Muhammad I.
    Khan, Amanullah
    Memon, Kamran I.
    Farid, Muhammad I.
    Kashif, Muhammad
    Mirjat, Dureali
    Ahmad, Maryam
    Raza, Tauseef
    Amjad, Muhammad H.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)