Control algorithm for dynamic solar shadings: A simulation study for office buildings based on ISO 52016-3

被引:0
|
作者
Bertini, Aurora [1 ]
Lamy, Herve [2 ,3 ]
Norouziasas, Alireza [4 ]
Van Dijk, Dick [5 ,6 ]
Dama, Alessandro [7 ]
Attia, Shady [1 ]
机构
[1] Univ Liege, Fac Appl Sci, Dept UEE, Sustainable Bldg Design Lab, Liege, Belgium
[2] Grp Actibaie, Paris, France
[3] Tech Comm ES S0, Brussels, Belgium
[4] Norwegian Univ Sci & Technol NTNU, Dept Civil & Environm Engn, Trondheim, Norway
[5] EPB Res, Delft, Netherlands
[6] Expert EPB Ctr, Rotterdam, Netherlands
[7] Politecn Milan, DOE, Milan, Italy
关键词
Adaptive fa & ccedil; ades; Multi -criteria control; Visual comfort; Energy needs; User satisfaction; Temperate climate; SYSTEMS; DEVICES; PERFORMANCE; CHALLENGES; STRATEGIES; OCCUPANTS;
D O I
10.1016/j.buildenv.2024.111818
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In 2019, the building sector was accountable for emitting 12GtCO2, equivalent to 21 % of global GHG emissions. To achieve carbon neutrality by 2050, the building sector must change its pace. One of the ways to achieve this goal is through the installation of dynamic solar shadings in buildings. This study focuses on a single office in two locations characterised by a temperate climate: Lie`ge (Belgium) and Milan (Italy). Two control strategies are designed for Venetian and Roller blinds, one with and one without glare evaluation. They both integrate horizontal illuminance, room occupancy, indoor operative temperature and vertical irradiance according to a multicriteria approach based on ISO 52016-3. The control strategy aims to balance visual comfort, heating, artificial lighting and cooling energy needs and considers user satisfaction by evaluating the shading activation time. The control algorithms are applied and validated on a DesignBuilder shoebox model. Regardless of location, the control strategy that includes glare control improves the user's visual comfort in terms of light quantity and discomfort glare. However, a total annual energy needs increase is registered independently of the shading. Conversely, if glare is not included in the control strategy, control of thermal loads is observed. This work contributed to developing ISO 52016-3 shading control scenarios for offices and is intended for shading producers, solar shading associations, fa & ccedil;ade engineers, facility managers and the scientific community working on solar shading simulation and analysis.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Simulation study on dynamic characteristics of electrical control type water distributor based on ADAMS
    Guo, Shujun
    Fan, Jun
    Dong, Ping
    Xu, Defu
    Key Engineering Materials, 2012, 522 : 396 - 399
  • [32] The study of three-dimensional simulation based on modified fuzzy control dynamic robots
    Guo-hui, S. (shuguohui123@163.com), 2012, Advanced Institute of Convergence Information Technology (04):
  • [33] Preliminary Study on Smoke Control Optimization Based on Genetic Algorithm Combined with Zone Modeling for Large Space Buildings
    Zhu Shi
    Huo Ran
    Hu Longhua
    Yang Dong
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL VII, PTS A AND B, 2008, 7 : 814 - 819
  • [34] Comparative study of the dynamic programming-based and rule-based operation strategies for grid-connected PV-battery systems of office buildings
    Zou, Bin
    Peng, Jinqing
    Li, Sihui
    Li, Yi
    Yan, Jinyue
    Yang, Hongxing
    APPLIED ENERGY, 2022, 305
  • [35] Study on the control algorithm for lower limb exoskeleton based on ADAMS/Simulink co-simulation
    Wu, Hongfang
    Jia, Tianyu
    Li, Na
    Wu, Jian
    Yan, Lei
    JOURNAL OF VIBROENGINEERING, 2017, 19 (04) : 2976 - 2986
  • [36] Simulation study on the PEMFC oxygen starvation based on the coupling algorithm of model predictive control and PID
    Wang, Yuhang
    Li, Haotian
    Feng, Huimin
    Han, Kuihua
    He, Suoying
    Gao, Ming
    ENERGY CONVERSION AND MANAGEMENT, 2021, 249
  • [37] A method based on environmental monitoring and building dynamic simulation to assess indoor climate control strategies in the preventive conservation within historical buildings
    Frasca, Francesca
    Cornaro, Cristina
    Siani, Anna Maria
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (09) : 1253 - 1268
  • [38] DO OFFICE BUILDINGS 'SAVE' ENERGY IN THE UNITED STATES DUE TO DAYLIGHT SAVING TIME (DST)? A 50-STATE SIMULATION-BASED STUDY
    Rakha, Tarek
    Chen, Yuanyue
    Reinhart, Christoph
    2018 BUILDING PERFORMANCE ANALYSIS CONFERENCE AND SIMBUILD, 2018, : 21 - 28
  • [39] Simulation Study on the Tracking Technology of the Maximal Power Point of the Solar Photovoltaic Based on the Model Predictive Control
    Zhao, Xia
    Zhao, Huailin
    Sugisaka, Masanori
    PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON ARTIFICIAL LIFE AND ROBOTICS (ICAROB 2016), 2016, : 405 - 411
  • [40] Application of dynamic simulation technology based on image detail enhancement algorithm in urban 3D landscape
    Cheng, Chen