The Orthodontic Mini-Implants Failures Based on Patient Outcomes: Systematic Review

被引:4
|
作者
Tarigan, Siti Harlianti Putri [1 ]
Sufarnap, Erliera [1 ]
Bahirrah, Siti [1 ]
机构
[1] Univ Sumatera Utara, Fac Dent, Orthodont Dept, Medan 20155, North Sumatera, Indonesia
关键词
PROSPERO Registration: CRD42022337684 (16/06/22); mini-implant; miniscrew; temporary anchorage device; orthodontic anchorage; mini-implant failure; TEMPORARY ANCHORAGE DEVICES; CORTICAL-BONE THICKNESS; SINGLE-TOOTH REPLACEMENT; LASER-LOK SURFACE; IN-VIVO FAILURE; MINISCREW IMPLANTS; SKELETAL ANCHORAGE; POSTERIOR REGION; SCREW IMPLANTS; SOFT-TISSUE;
D O I
10.1055/s-0043-1772249
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Anchorage is a challenge and essential issue for an orthodontist in determining the success of orthodontic treatment. Orthodontic anchorage is defined as resistance to unwanted tooth movement. Mini-implant is one of the devices that can be used as an anchor in orthodontic treatment. Many cases have reported successful treatment using mini-implant, but there are cases where mini-implants may fail. Failure of mini-implants can affect orthodontic treatment, and it is known that several factors may lead to mini-implant loss in orthodontic treatment. This systematic review aimed to determine the factors influencing mini-implant failure in orthodontic treatment. Articles were selected from electronic databases (PubMed, Google Scholar, The Cochrane Library, ScienceDirect) from January 2015 until 2023 according to the PRISMA method ( Preferred Reporting Items for Systematic Reviews and Meta-Analysis ) under the PEOS (Population-Exposure-Outcome-StudyType) framework questions for systematic review. The study was registered in the International Prospective Register of Systematic Reviews (PROSPERO) database (CRD42022337684). All data collected were in English, and filtering was done by eliminating duplicate data, meta-analysis, case reports, case series, mini-reviews, and animal studies. The analysis was further divided into three groups, that is, patient-related, implant-related, and operator-related and operator-related (A graphical abstract provided as a Supplementary information [available in the online version]). Twenty-one articles were identified according to the inclusion criteria in the form of retrospective, prospective, in vivo , and randomized controlled trial studies. Mini-implant failures due to patient-related showed six etiological factors, failures due to implant-related had eight etiological factors, and only one factor was operator-related, which may lead to mini-implant failure. The data was extracted without a computerized system and only in English. Mini-implant failure can be caused by many factors; we could not accuse one major factor as a cause. However, the quality or condition of the bones and oral hygiene are factors that play a significant role in obtaining the stability of implants. Mini-implant failure is highly influenced by poor oral hygiene and peri-implant inflammation. Comprehensive diagnostic prior to mini-implant insertion should be appropriately considered. This systematic review describes several factors that can influence mini-implant failure, divided into three groups: patient-related, implant-related, and operator-related (A graphical abstract provided as a Supplementary information [available in the online version]).
引用
收藏
页码:417 / 429
页数:13
相关论文
共 50 条
  • [21] Mechanical strength of orthodontic infrazygomatic mini-implants
    Chau-Hsiang Wang
    Ju-Hui Wu
    Kun-Tsung Lee
    Kun-Rong Hsu
    Huang Chi Wang
    Chun-Ming Chen
    Odontology, 2011, 99 : 98 - 100
  • [22] Morphological and structural characteristics of orthodontic mini-implants
    AlSamak, Saeed
    Bitsanis, Elias
    Makou, Margarita
    Eliades, George
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2012, 73 (01): : 58 - 71
  • [23] Mini-Implants in Dentistry – A Review
    Duraisamy R.
    Ganapathy D.M.
    Rajeshkumar S.
    Ashok V.
    Journal of Long-Term Effects of Medical Implants, 2022, 32 (03) : 29 - 37
  • [24] Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: A systematic review
    Meursinge Reynders R.
    Ladu L.
    Ronchi L.
    Di Girolamo N.
    de Lange J.
    Roberts N.
    Plüddemann A.
    Systematic Reviews, 5 (1)
  • [25] Design of orthodontic mini-implants contributing to implantation torque
    Katic, V.
    Spalj, S.
    Opalic, M.
    Domitran, Z.
    BIODENTAL ENGINEERING II, 2014, : 29 - 33
  • [26] Revisiting the stability of mini-implants used for orthodontic anchorage
    Yao, Chung-Chen Jane
    Chang, Hao-Hueng
    Chang, Jenny Zwei-Chieng
    Lai, Hsiang-Hua
    Lu, Shao-Chun
    Chen, Yi-Jane
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2015, 114 (11) : 1122 - 1128
  • [27] Orthodontic Mini-Implants Hybrid Expanders in Palatal Expansion
    Szuhanek, Camelia
    Nagib, Riham
    Sinescu, Cosmin
    Negrutiu, Meda Lavinia
    Manea, Nicoleta
    Buzatu, Roxana
    Dumitrescu, Stefania
    Mesaros, Anca
    Cocir, Razvan
    Schiller, Leonora
    Sarbu, Adina
    REVISTA DE CHIMIE, 2018, 69 (07): : 1905 - 1906
  • [28] Long-term durability of orthodontic mini-implants
    Mona Aly Abbassy
    Ahmed Samir Bakry
    Khalid Hashim Zawawi
    Ali Habib Hassan
    Odontology, 2018, 106 : 208 - 214
  • [29] Predrilling of the implant site: Is it necessary for orthodontic mini-implants?
    Baumgaertel, Sebastian
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (06) : 825 - 829
  • [30] Investigation of bacteremia induced by removal of orthodontic mini-implants
    Livas, Christos
    Delli, Konstantina
    Karapsias, Stergios
    Pandis, Nikolaos
    Ren, Yijin
    EUROPEAN JOURNAL OF ORTHODONTICS, 2014, 36 (01) : 16 - 21