Experimental assessment of a solar vortex engine integrated with sensible TES at different collector configurations

被引:2
|
作者
Al-Kayiem, Hussain H. [1 ]
Tukkee, Ali M. [2 ,3 ]
See, Yuan K. [4 ]
机构
[1] Hilla Univ Coll, Air Conditioning & Refrigerat Tech Engn Dept, Babylon, Iraq
[2] Univ Kerbala, Dept Petr Engn, Karbala, Iraq
[3] Univ Warith Al Anbiyaa, Air Conditioning & Refrigerat Tech Engn Dept, Karbala Baghdad Rd, Karbala 56001, Iraq
[4] PETRONAS, Project Delivery & Technol, Kuala Lumpur, Malaysia
关键词
Solar thermal; Solar updraft; Vortex engine; Solar collector; Vortex generator; CHIMNEY POWER-PLANT; HEAT-CONVECTION; GEOMETRIC PARAMETERS; MECHANICAL ENERGY; WORK CONVERSION; PERFORMANCE; INCLINATION; DIMENSION; HEIGHT; FLOW;
D O I
10.1016/j.renene.2024.120539
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study presents an experimental investigation of the effect of different solar collector geometrical parameters on the solar vortex engine ' s (SVE) performance. The first parametric study is concerned with a solar vortex power generation system ' s diameter, inlet height, and thermal energy storage (TES) extension. The experimental results revealed that extending the TES by 1 m outside the canopy significantly increases thermal efficiency by 62 %. In addition, increasing the diameter of the solar collector from 8.8 m to 10.8 m, with an extra 1 m extended TES area, increased the air temperature rise by 57 %, while the outlet air velocity increased by 32 %. On the other hand, a reduction in the collector inlet height from 0.2 m to 0.15 increased the air temperature rise while decreasing the outlet air velocity and power output potential by mean values of 19 % and 48 %, respectively. The enhancement obtained from the extended area of TES is an important finding, as it increased the air temperature for a larger canopy size without extra cost. Therefore, increasing the absorption area or the TES outside the canopy is recommended. Also, further studies are essential to correlate the inlet height to the system ' s performance.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] EXPERIMENTAL MEASUREMENTS AND SYSTEM IMPLICATIONS OF PERFORMANCE OF FLAT-PLATE SOLAR COLLECTOR CONFIGURATIONS
    SWANSON, SR
    BOEHM, RF
    MECHANICAL ENGINEERING, 1977, 99 (03) : 102 - 102
  • [22] Experimental and computational investigation of a new solar integrated collector storage system
    Borello, Domenico
    Corsini, Alessandro
    Delibra, Giovanni
    Evangelisti, Sara
    Micangeli, Andrea
    APPLIED ENERGY, 2012, 97 : 982 - 989
  • [23] Sustainability assessment of hybrid active greenhouse solar dryer integrated with evacuated solar collector
    Singh, Pushpendra
    Gaur, M. K.
    CURRENT RESEARCH IN FOOD SCIENCE, 2021, 4 : 684 - 691
  • [24] Numerical investigation on thermal performance of three configurations of solar thermal collector integrated with metal hydride
    Alqahtani, Talal
    Mellouli, Sofiene
    Askri, Faouzi
    Algarni, Salem
    Alshammari, Badr M.
    Kolsi, Lioua
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 63
  • [25] An experimental comparative study on different configurations of basin solar still
    Ensafisoroor, Hamed
    Khamooshi, Mehrdad
    Egelioglu, Fuat
    Parham, Kiyan
    DESALINATION AND WATER TREATMENT, 2016, 57 (05) : 1901 - 1916
  • [26] Experimental exergy analyses on fabricated parabolic solar collector with/without preheater and different collector materials
    Geete, Ankur
    Sharma, Rajat
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2019, 40 (06) : 577 - 589
  • [27] Thermoeconomic Study of Different Configurations of iscc (Integrated Solar Combined Cycle)
    Duran Garcia, Maria Dolores
    Rincon Mejia, Eduardo Armando
    Martinez Cienfuegos, Ivan Galileo
    Almanza Salgado, Rafael
    Lentz Herrera, Alvaro
    CIENCIA ERGO-SUM, 2014, 21 (01) : 27 - 35
  • [28] Experimental and numerical investigation on the performance of square cyclones with different vortex finder configurations
    Wasilewski, Marek
    Brar, Lakhbir Singh
    Ligus, Grzegorz
    SEPARATION AND PURIFICATION TECHNOLOGY, 2020, 239 (239)
  • [29] Experimental investigation of heat removal factor in solar flat plate collector for various flow configurations
    Malvi, C. S.
    Gupta, Arpit
    Gaur, M. K.
    Crook, R.
    Dixon-Hardy, D. W.
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2017, 14 (04) : 442 - 448
  • [30] How collector entrance influences the solar chimney performance: experimental assessment
    Golzardi, Sajad
    Mehdipour, Ramin
    Baniamerian, Zahra
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 146 (02) : 813 - 826