Evaluation of agreement between a noninvasive method for real-time measurement of critical blood values with a standard point-of-care device

被引:0
|
作者
Ettrich, Rudi H. [1 ,2 ]
Caballero, Joshua [3 ]
Sakharkar, Prashant [4 ]
Ahmed, Sultan [1 ]
Hurlston, Traci [1 ]
Parmar, Jayesh [4 ]
Deb, Subrata [4 ]
机构
[1] Larkin Univ, Coll Biomed Sci, Miami, FL 33169 USA
[2] Florida Int Univ, Wertheim Coll Med, Miami, FL 33199 USA
[3] Univ Georgia, Coll Pharm, Athens, GA USA
[4] Larkin Univ, Coll Pharm, Miami, FL 33169 USA
来源
PLOS ONE | 2024年 / 19卷 / 06期
关键词
D O I
10.1371/journal.pone.0304706
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The purpose of this work was to investigate the degree of agreement between two distinct approaches for measuring a set of blood values and to compare comfort levels reported by participants when utilizing these two disparate measurement methods. Radial arterial blood was collected for the comparator analysis using the Abbott i-STAT (R) POCT device. In contrast, the non-invasive proprietary DBC methodology is used to calculate sodium, potassium, chloride, ionized calcium, total carbon dioxide, pH, bicarbonate, and oxygen saturation using four input parameters (temperature, hemoglobin, pO2, and pCO2). Agreement between the measurement for a set of blood values obtained using i-STAT and DBC methodology was compared using intraclass correlation coefficients, Passing and Bablok regression analyses, and Bland Altman plots. A p-value of <0.05 was considered statistically significant. A total of 37 participants were included in this study. The mean age of the participants was 42.4 +/- 13 years, most were male (65%), predominantly Caucasian/White (75%), and of Hispanic ethnicity (40%). The Intraclass Correlation Coefficients (ICC) analyses indicated agreement levels ranging from poor to moderate between i-STAT and the DBC's algorithm for Hb, pCO2, HCO3, TCO2, and Na, and weak agreement for pO2, HSO2, pH, K, Ca, and Cl. The Passing and Bablok regression analyses demonstrated that values for Hb, pO2, pCO2, TCO2, Cl, and Na obtained from the i-STAT did not differ significantly from that of the DBC's algorithm suggesting good agreement. The values for Hb, K, and Na measured by the DBC algorithm were slightly higher than those obtained by the i-STAT, indicating some systematic differences between these two methods on Bland Altman Plots. The non-invasive DBC methodology was found to be reliable and robust for most of the measured blood values compared to invasive POCT i-STAT device in healthy participants. These findings need further validation in larger samples and among individuals afflicted with various medical conditions.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Point-of-care blood gases and critical care blood chemistry and haematology reference values in captive gyr falcons (Falco rusticolus)
    Samour J.
    Magno M.N.
    Comparative Clinical Pathology, 2016, 25 (5) : 993 - 999
  • [42] Performance Evaluation of Real-Time Precise Point Positioning Method
    Alcay, Salih
    Turgut, Muzeyyen
    WORLD MULTIDISCIPLINARY EARTH SCIENCES SYMPOSIUM (WMESS 2017), 2017, 95
  • [43] Hydrophilic Pyrazine Dyes as Exogenous Fluorescent Tracer Agents for Real-Time Point-of-Care Measurement of Glomerular Filtration Rate
    Rajagopalan, Raghavan
    Neumann, William L.
    Poreddy, Amruta R.
    Fitch, Richard M.
    Freskos, John N.
    Asmelash, Bethel
    Gaston, Kimberly R.
    Galen, Karen P.
    Shieh, Jeng-Jong
    Dorshow, Richard B.
    JOURNAL OF MEDICINAL CHEMISTRY, 2011, 54 (14) : 5048 - 5058
  • [44] Real-time point-of-care total protein measurement with a miniaturized optoelectronic biosensor and fast fluorescence-based assay
    Mahzabeen, Fariah
    Vermesh, Ophir
    Levi, Jelena
    Tan, Marilyn
    Alam, Israt S.
    Chan, Carmel T.
    Gambhir, Sanjiv S.
    Harris, James S.
    BIOSENSORS & BIOELECTRONICS, 2021, 180
  • [45] Microfluidic device and system for point-of-care blood coagulation measurement based on electrical impedance sensing
    Ramaswamy, Bharath
    Yeh, Yin-Ting Tim
    Zheng, Si-Yang
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 180 : 21 - 27
  • [46] Plasmonic and label-free real-time quantitative PCR for point-of-care diagnostics
    Mohammadyousef, Padideh
    Paliouras, Miltiadis
    Trifiro, Mark A.
    Kirk, Andrew G.
    ANALYST, 2021, 146 (18) : 5619 - 5630
  • [47] TPU Based Deep Learning Image Enhancement for Real-Time Point-of-Care Ultrasound
    Huang, Ouwen
    Palmeri, Mark L.
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2024, 10 : 461 - 468
  • [48] AUTOMATED IMAGE PROCESSING WITH POINT-OF-CARE OCULAR ULTRASOUND FOR REAL-TIME ICP MONITORING
    You, David
    LaFonte, Marc
    Hacihaliloglu, Ilker
    Lissauer, Matthew
    CRITICAL CARE MEDICINE, 2022, 50 (01) : 274 - 274
  • [49] Electrochemical real-time nucleic acid amplification: towards point-of-care quantification of pathogens
    Patterson, Adriana S.
    Hsieh, Kuangwen
    Soh, H. Tom
    Plaxco, Kevin W.
    TRENDS IN BIOTECHNOLOGY, 2013, 31 (12) : 704 - 712
  • [50] Real-time Visual Analysis of Microvascular Blood Flow for Critical Care
    Liu, Chao
    Gomez, Hernando
    Narasimhan, Srinivasa
    Dubrawski, Artur
    Pinsky, Michael R.
    Zuckerbraun, Brian
    2015 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2015, : 2217 - 2225