A Versatile 8-Channel High Voltage Stimulator for Comprehensive Neural Stimulation

被引:0
|
作者
Lin, Kuan-Ting [1 ]
Ker, Ming-Dou [1 ]
机构
[1] Natl Yang Ming Chiao Tung Univ, Inst Elect, Hsinchu, Taiwan
来源
2024 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, ISCAS 2024 | 2024年
关键词
Neuromodulation; high voltage stimulator; current stimulation; voltage stimulation; bipolar stimulator; monopolar stimulator; deep brain stimulation (DBS); ELECTRICAL-STIMULATION; DESIGN;
D O I
10.1109/ISCAS58744.2024.10557993
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A dual-configuration dual-mode 8-channel high voltage stimulator is proposed and designed for biomedical applications. Dual-configuration indicates the choice between a bipolar or monopolar structural arrangement, while dual-mode refers to the selection between constant current or constant voltage stimulation. With supply voltages of 1.8 V, +/- 5 V, +/- 10 V, and +/- 15 V, the range of stimulus current is +/- 0.2 mA to +/- 10 mA with a 0.2 mA/step increment, and the range of stimulus voltage is +/- 0.2 V to +/- 10 V with a 0.2 V/step increment. The 8-channel stimulator chip has been fabricated in a 0.18-mu m BCD process with a silicon area of 3570 mu m x 1636 mu m. Moreover, stimulus functions have been successfully verified through experiments in agar with Pt electrodes and in-vivo animal test on pig with DBS electrode.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] An 8-Channel Neural Spike Processing IC with Unsupervised Closed-Loop Control Based On Spiking Probability Estimation
    Wu, Tong
    Yang, Zhi
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 5260 - 5263
  • [32] A high power efficient multi-waveform current stimulator used in implantable neural stimulation
    Mooziraji, Farhad Bozorgi
    Shoaei, Omid
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2016, 86 (03) : 459 - 469
  • [33] A high power efficient multi-waveform current stimulator used in implantable neural stimulation
    Farhad Bozorgi Mooziraji
    Omid Shoaei
    Analog Integrated Circuits and Signal Processing, 2016, 86 : 459 - 469
  • [34] SUAS for 8-Channel GMTI Radar Using Alternative High Performance Non-SMI STAP Algorithm
    Marple, S. Lawrence, Jr.
    2012 IEEE 7TH SENSOR ARRAY AND MULTICHANNEL SIGNAL PROCESSING WORKSHOP (SAM), 2012, : 417 - 420
  • [35] A 79μW 0.24mm2 8-channel Neural Signal Recording Front-End Integrated Circuit
    Rehman, Sami Ur
    Kamboh, Awais M.
    Yang, Yuning
    2017 INTERNATIONAL CONFERENCE ON APPLIED ELECTRONICS (AE), 2017, : 183 - 186
  • [36] MONOLITHIC 8-CHANNEL HIGH-POWER LOW-ASTIGMATISM ALGAAS LASER DIODE-ARRAY
    TSUNEKANE, M
    ENDO, K
    ISHIKAWA, S
    KATAYAMA, R
    YOSHIHARA, K
    KUBOTA, K
    YUASA, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1989, 28 (03): : L468 - L469
  • [37] A 64 channelprogrammable closed-loop deep brain stimulator with 8 channel neural amplifier and logarithmic ADC
    Lee, Jongwoo
    Rhew, Hyo-Gyuem
    Kipke, Daryl
    Flynn, Michael
    2008 SYMPOSIUM ON VLSI CIRCUITS, DIGEST OF TECHNICAL PAPERS, 2008, : 76 - 77
  • [38] A 64 ChannelProgrammable closed-loop deep brain stimulator with 8 channel neural amplifier and logarithmic ADC
    Lee, Jongwoo
    Rhew, Hyo-Gyuem
    Kipke, Daryl
    Flynn, Michael
    2008 IEEE SYMPOSIUM ON VLSI CIRCUITS, 2008, : 61 - 62
  • [39] A high-performance 8 nV/√Hz 8-channel wearable and wireless system for real-time monitoring of bioelectrical signals
    Konstantinos Petkos
    Simos Koutsoftidis
    Thomas Guiho
    Patrick Degenaar
    Andrew Jackson
    Stephen E. Greenwald
    Peter Brown
    Timothy Denison
    Emmanuel M. Drakakis
    Journal of NeuroEngineering and Rehabilitation, 16
  • [40] Versatile 3-channel high-voltage power supply for microchip capillary electrophoresis
    García, CD
    Liu, Y
    Anderson, P
    Henry, CS
    LAB ON A CHIP, 2003, 3 (04) : 324 - 328