A one-dimensional computational model for blood flow in an elastic blood vessel with a rigid catheter

被引:1
|
作者
Pradhan, Aseem Milind [1 ]
Mut, Fernando [1 ]
Cebral, Juan Raul [1 ]
机构
[1] George Mason Univ, Bioengn Dept, Fairfax, VA 22030 USA
关键词
1D blood flow; annular fluid flow; catheter insertion; computational hemodynamics; discontinuous Galerkin methods; endovascular interventions; ACUTE ISCHEMIC-STROKE; OSCILLATORY FLOW; THROMBECTOMY; ASPIRATION; PRESSURE; ARTERY; SIMULATION; GEOMETRY; REMOVAL; FLUID;
D O I
10.1002/cnm.3834
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Strokes are one of the leading causes of death in the United States. Stroke treatment involves removal or dissolution of the obstruction (usually a clot) in the blocked artery by catheter insertion. A computer simulation to systematically plan such patient-specific treatments needs a network of about 105 blood vessels including collaterals. The existing computational fluid dynamic (CFD) solvers are not employed for stroke treatment planning as they are incapable of providing solutions for such big arterial trees in a reasonable amount of time. This work presents a novel one-dimensional mathematical formulation for blood flow modeling in an elastic blood vessel with a centrally placed rigid catheter. The governing equations are first-order hyperbolic partial differential equations, and the hypergeometric function needs to be computed to obtain the characteristic system of these hyperbolic equations. We employed the Discontinuous Galerkin method to solve the hyperbolic system and validated the implementation by comparing it against a well-established 3D CFD solver using idealized vessels and a realistic truncated arterial network. The results showed clinically insignificant differences in steady flow cases, with overall variations between 1D and 3D models remaining below 10%. Additionally, the solver accurately captured wave reflection phenomena at domain discontinuities in unsteady cases. A primary advantage of this model over 3D solvers is its ease in obtaining a discretized geometry of complex vasculatures with multiple arterial branches. Thus, the 1D computational model offers good accuracy and applicability in simulating complex vasculatures, demonstrating promising potential for investigating patient-specific endovascular interventions in strokes. This work presents a novel 1D model of blood flow in an annular section defined by an elastic blood vessel and centrally placed catheter. The 1D equations are solved using a discontinuous Galerkin method to obtain accurate hemodynamic values of pressure and flow rates for various test cases and a realistic arterial tree geometry. This formulation could be very useful to model pulse wave propagation in complex catheterized arterial networks. image
引用
收藏
页数:29
相关论文
共 50 条
  • [31] FLOW IN AN ARTERIOSCLEROTIC BLOOD-VESSEL WITH RIGID PERMEABLE WALL
    GUHA, HS
    CHAUDHURY, TK
    BULLETIN OF MATHEMATICAL BIOLOGY, 1985, 47 (05) : 613 - 627
  • [32] Elastic nonlinearities in a one-dimensional model of fracture
    Bouchbinder, Eran
    Lo, Ting-Shek
    PHYSICAL REVIEW E, 2008, 78 (05):
  • [33] A one dimensional model of blood flow through a curvilinear artery
    Berntsson, F.
    Ghosh, A.
    Kozlov, V. A.
    Nazarov, S. A.
    APPLIED MATHEMATICAL MODELLING, 2018, 63 : 633 - 643
  • [34] A one dimensional model for blood flow: Application to vascular prosthesis
    Formaggia, L
    Nobile, F
    Quarteroni, A
    MATHEMATICAL MODELING AND NUMERICAL SIMULATION IN CONTINUUM MECHANICS, 2002, 19 : 137 - 153
  • [35] Influence of boundary conditions on a one-dimensional ultrasound backscattering model of blood
    Lui, EYL
    Tavakkoli, J
    Cobbold, RSC
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (04): : 571 - 578
  • [36] ON THE MODELING OF DISTRIBUTED OUTFLOW IN ONE-DIMENSIONAL MODELS OF ARTERIAL BLOOD-FLOW
    SMIT, CH
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND PHYSIK, 1981, 32 (04): : 408 - 420
  • [37] Consistent treatment of viscoelastic effects at junctions in one-dimensional blood flow models
    Muller, Lucas O.
    Leugering, Guenter
    Blanco, Pablo J.
    JOURNAL OF COMPUTATIONAL PHYSICS, 2016, 314 : 167 - 193
  • [38] A benchmark study of numerical schemes for one-dimensional arterial blood flow modelling
    Boileau, Etienne
    Nithiarasu, Perumal
    Blanco, Pablo J.
    Mueller, Lucas O.
    Fossan, Fredrik Eikeland
    Hellevik, Leif Rune
    Donders, Wouter P.
    Huberts, Wouter
    Willemet, Marie
    Alastruey, Jordi
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2015, 31 (10) : 1 - 33
  • [39] SIMPLE MODEL OF BLOOD VESSEL SYSTEM FOR SIMULATION OF STATIONARY BLOOD FLOW .1. TOPOLOGICALLY VARIABLE MODEL OF BRANCHED, RIGID TUBES
    RANFT, U
    PESTEL, R
    BIOMEDIZINISCHE TECHNIK, 1974, 19 (03): : 102 - 105
  • [40] TWO-DIMENSIONAL FLOW IN COMPLIANT CHANNEL AS A MODEL OF THE BLOOD-VESSEL
    TAKEMITSU, N
    MATUNOBU, Y
    BIORHEOLOGY, 1985, 22 (04) : 348 - 348