Evaluation of bone integrity around the acetabular cup using noninvasive laser resonance frequency analysis

被引:1
|
作者
Hatakeyama, Takuto [1 ]
Nakashima, Daisuke [1 ,2 ]
Mikami, Katsuhiro [3 ]
Oya, Akihito [1 ]
Fujie, Atsuhiro [1 ]
Sujino, Asahi [1 ]
Nakamura, Masaya [1 ]
Nagura, Takeo [1 ,2 ]
机构
[1] Keio Univ, Sch Med, Dept Orthopaed Surg, 35 Shinanomachi,Shinjuku Ku, Tokyo 1608582, Japan
[2] Keio Univ, Sch Med, Dept Clin Biomech, Shinjuku Ku, Tokyo, Japan
[3] Kindai Univ, Fac Biol Oriented Sci & Technol, Kinokawa, Wakayama, Japan
关键词
bone integrity; bone mineral density; laser resonance frequency analysis; noninvasive; resonance frequency; TOTAL HIP-ARTHROPLASTY; IMPLANT STABILITY; INITIAL STABILITY; MINERAL DENSITY; 2-YEAR RSA; DESIGN;
D O I
10.1002/jor.25925
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Resonance frequency analysis (RFA) is valuable for assessing implant status. In a previous investigation, acetabular cup fixation was assessed using laser RFA and the pull-down force was predicted in an in vitro setting. While the pull-down force alone is sufficient for initial fixation evaluation, it is desirable to evaluate the bone strength of the foundation for subsequent fixation. Diminished bone quality causes micromotion, migration, and protracted osseointegration, consequently elevating susceptibility to periprosthetic fractures and failure of ingrained trabecular bone. Limited research exists on the evaluation of bone mineral density (BMD) around the cup using RFA. For in vivo application of laser RFA, we implemented the sweep pulse excitation method and engineered an innovative laser RFA device having low laser energy and small dimensions. We focused on a specific frequency range (2500-4500 Hz), where the peak frequency was presumed to be influenced by foundational density. Quantitative computed tomography with a phantom was employed to assess periprosthetic BMD. Correlation between the resonance frequency within the designated range and the density around the cup was evaluated both in the laboratory and in vivo using the novel laser RFA device. The Kruskal-Wallis test showed robust correlations in both experiments (laboratory study: R = 0.728, p < 0.001; in vivo study: R = 0.619, p < 0.001). Our laser RFA system can assess the quality of bone surrounding the cup. Laser RFA holds promise in predicting the risk of loosening and might aid in the decision-making process for additional fixation through screw insertion.
引用
收藏
页码:2552 / 2561
页数:10
相关论文
共 50 条
  • [1] Evaluation of acetabular cup initial fixation by using resonance frequency principle
    Henys, Petr
    Capek, Lukas
    Fencl, Jaroslav
    Prochazka, Egon
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2015, 229 (01) : 3 - 8
  • [2] Laser Resonance Frequency Analysis: A Novel Measurement Approach to Evaluate Acetabular Cup Stability During Surgery
    Kikuchi, Shunsuke
    Mikami, Katsuhiro
    Nakashima, Daisuke
    Kitamura, Toshiyuki
    Hasegawa, Noboru
    Nishikino, Masaharu
    Kanaji, Arihiko
    Nakamura, Masaya
    Nagura, Takeo
    SENSORS, 2019, 19 (22)
  • [3] Effect of Implant Materials on Bone Remodelling Around Cemented Acetabular Cup
    Kumar, Ajay
    Ghosh, Rajesh
    Kumar, Rajeev
    MACHINES, MECHANISM AND ROBOTICS, INACOMM 2019, 2022, : 17 - 26
  • [4] Denosumab prevents acetabular bone loss around an uncemented cup: analysis of secondary outcomes in a randomized controlled trial
    Kiritopoulos, Demostenis
    Nystrom, Andreas
    Ullmark, Gosta
    Sorensen, Jens
    Petren-Mallmin, Marianne
    Milbrink, Jan
    Hailer, Nils P.
    Mallmin, Hans
    ACTA ORTHOPAEDICA, 2022, 93 : 709 - 720
  • [5] Bone integrity described by resonance frequency signature
    Gabrielli, F.
    Guillemain, P.
    Ogam, E.
    Masson, C.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2008, 11 : 95 - 96
  • [6] In Vitro Evaluation of the Acetabular Cup Primary Stability by Impact Analysis
    Michel, Adrien
    Bosc, Romain
    Vayron, Romain
    Haiat, Guillaume
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2015, 137 (03):
  • [7] Computed tomographic analysis of bone support for three acetabular cup designs
    Howard, JL
    Hui, AJ
    Bourne, RB
    Holdsworth, DW
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (434) : 163 - 169
  • [8] Pre-clinical analysis of an acetabular cup with improved in-vivo stability and integrity
    Dickinson, A.
    Browne, M.
    Jeffers, J.
    Taylor, A.
    Key Engineering Materials, 2009, 396-398 : 31 - 34
  • [9] Pre-clinical Analysis of an Acetabular Cup with Improved in-vivo Stability and Integrity
    Dickinson, A.
    Browne, M.
    Jeffers, J.
    Taylor, A.
    BIOCERAMICS 21, 2009, 396-398 : 31 - 34
  • [10] Treatment of Severe Acetabular Bone Loss Using a Tantalum Acetabular Shell and a Cemented Monoblock Dual Mobility Acetabular Cup
    Melnic, Christopher M.
    Cohen-Levy, Wayne B.
    Lozano-Calderon, Santiago A.
    Heng, Marilyn