How to Reduce Inferomedial Orbital Wall Fracture Using a Navigation System: Tips and Pearls

被引:1
|
作者
Park, Tae Hwan [1 ]
机构
[1] Hallym Univ, Coll Med, Dongtan Sacred Heart Hosp, Dept Plast & Reconstruct Surg, 40 Sukwoo Dong, Hwaseong 18450, South Korea
关键词
Blowout; diplopia; enophthalmos; facial bone; fracture; orbit; DERMAL MATRIX; RECONSTRUCTION; FLOOR;
D O I
10.1097/SCS.0000000000010034
中图分类号
R61 [外科手术学];
学科分类号
摘要
The orbit is a confined space with a defined bony structure. Bony protrusion into the ethmoid or maxillary sinuses by the blowout fracture can displace orbital tissues, including rectus muscles and adjacent fascial septae. Especially, reconstructing the orbit's floor and medial wall can be challenging when the inferomedial strut or posterior bony ledge is affected, leading to a loss of critical anatomic landmarks and support. Correctly positioning an implant in the precise anatomic location can be challenging. Recent updates to the navigation system have addressed this issue. Despite its early application, using a navigation system in these orbital fractures advances plastic surgeons in a way that has more confidence and accuracy in surgical planning. The video demonstrates how these 2 can be combined in an operating room. Intraoperatively, the authors check the superior, anterior, and posterior ends of the medial wall fracture and the posterior end of the floor fracture. A single orbital implant was trimmed and reshaped to match defect measurements. The implant placement was meticulously executed to repair the fracture while ensuring the inferior oblique muscle was not injured. After confirming the correct placement of the implant, it was secured to the inferior orbital rim using a single screw. Depending on the medial orbital wall fracture depth or degree of soft tissue herniation, the authors used an artificial dermal matrix or trimmed absorbable mesh plate to cover the uppermost part of the medial wall fracture to prevent postoperative enophthalmos. Finally, a forced duction test was performed. Our study shows that navigation-assisted inferomedial orbital wall reconstruction using materials readily available in the market is safe and effective.
引用
收藏
页码:962 / 964
页数:3
相关论文
共 50 条
  • [41] Long bone fracture reduction using a fluoroscopy-based navigation system: A feasibility and accuracy study
    Weil, Yoram A.
    Liebergall, Meir
    Mosheiff, Rami
    Helfet, David L.
    Pearle, Andrew D.
    COMPUTER AIDED SURGERY, 2007, 12 (05) : 295 - 302
  • [42] Accuracy analysis of computer-assisted surgery for femoral trochanteric fracture using a fluoroscopic navigation system: Stryker ADAPT® system
    Takai, Hirokazu
    Murayama, Masatoshi
    Kii, Sakumo
    Mito, Daisuke
    Hayai, Chihiro
    Motohashi, Satoru
    Takahashi, Tomoki
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (06): : 1149 - 1154
  • [43] Navigation-Assisted Orbital Trauma Reconstruction Using a Bioactive Osteoconductive/Bioresorbable u-HA/PLLA System
    Takahiro Kanno
    Shintaro Sukegawa
    Masaaki Karino
    Yoshihiko Furuki
    Journal of Maxillofacial and Oral Surgery, 2019, 18 : 329 - 338
  • [44] Navigation-Assisted Orbital Trauma Reconstruction Using a Bioactive Osteoconductive/Bioresorbable u-HA/PLLA System
    Kanno, Takahiro
    Sukegawa, Shintaro
    Karino, Masaaki
    Furuki, Yoshihiko
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2019, 18 (03): : 329 - 338
  • [45] Revisiting bilateral bony orbital volumes comparison using 3D reconstruction in Korean adults: a reference study for orbital wall reconstruction, 3D printing, and navigation by mirroring
    Hahn, Hyung Min
    Jung, Yeon Kyo
    Lee, Il Jae
    Lim, Hyoseob
    BMC SURGERY, 2023, 23 (01)
  • [46] Revisiting bilateral bony orbital volumes comparison using 3D reconstruction in Korean adults: a reference study for orbital wall reconstruction, 3D printing, and navigation by mirroring
    Hyung Min Hahn
    Yeon Kyo Jung
    Il Jae Lee
    Hyoseob Lim
    BMC Surgery, 23
  • [47] Tibial plateau stress fracture after unicondylar knee arthroplasty using a navigation system: two case reports
    Seon, Jong Keun
    Song, Eun Kyoo
    Yoon, Taek Rim
    Seo, Hyoung Yeon
    Cho, Sang Gwon
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2007, 15 (01) : 67 - 70
  • [48] Tibial plateau stress fracture after unicondylar knee arthroplasty using a navigation system: two case reports
    Jong Keun Seon
    Eun Kyoo Song
    Taek Rim Yoon
    Hyoung Yeon Seo
    Sang Gwon Cho
    Knee Surgery, Sports Traumatology, Arthroscopy, 2007, 15 : 67 - 70
  • [49] Endoscopic trans-nasal approach for biopsy of orbital tumours using image-guided neuro-navigation system
    A. Sieskiewicz
    T. Lyson
    Z. Mariak
    M. Rogowski
    Acta Neurochirurgica, 2008, 150 : 441 - 445
  • [50] Endoscopic trans-nasal approach for biopsy of orbital tumours using image-guided neuro-navigation system
    Sieskiewicz, A.
    Lyson, T.
    Mariak, Z.
    Rogowski, M.
    ACTA NEUROCHIRURGICA, 2008, 150 (05) : 441 - 445