Planar Ag/AgCl Reference Electrode for Electrochemical Agronomic Sensors

被引:0
|
作者
Mamilla, Sreenivasulu [1 ]
Yousuf, Shah Zahid [1 ]
Avulapati, Madan Mohan [2 ]
Ahmed-Al Mallahi
Murty, N. V. L. Narasimha [1 ]
机构
[1] Indian Inst Technol Tirupati, Dept Elect Engn, Tirupati 517619, India
[2] Indian Inst Technol Tirupati, Dept Mech Engn, Tirupati 517619, India
关键词
Sensor phenomena; DC magnetron sputtering; electrochemical impedance spectroscopy; graphene conductive ink (GCI); Planar Ag/AgCl reference electrode (PARE);
D O I
10.1109/LSENS.2024.3407928
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Robust, stable, and portable planar reference electrodes that perform analogous to conventional Ag/AgCl reference electrodes are of paramount importance for any electrochemical soil sensors, such as soil pH and NPK sensors. This letter reports the fabrication and characterization of planar Ag/AgCl reference electrode (PARE) with graphene conductive ink (GCI) as a protective layer. For its application in soil agronomy, the fabricated PARE is exclusively tested in soil solutions with different pH, 1 M KCl and pH buffer solutions. The fabricated PARE exhibited a drift of +/- 3 mV in pH buffers and is relatively insensitive to changes in pH. The drift in the open circuit potential of the PARE without GCI is found to be +/- 10.02 mV for a period of 72 h in 1 M KCl, whereas the drift with GCI is significantly reduced to +/- 0.98 mV resulting in a stable response. Furthermore, electrochemical impedance spectroscopic studies are performed to examine the protective layer's contribution to sustaining electrode stability over extended periods of time. Finally, the PARE is proven to be stable, exhibiting minimal drift for varying soil pH levels, indicating its potential as a stable reference electrode for agronomic applications.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Ag/AgCl Reference Electrode Based on Thin Film of Arabic Gum Membrane
    Alva, Sagir
    Aziz, Aiman Sajidah Binti Abdul
    bin Syono, Mohd Ismahadi
    Jamil, Wan Adil bin Wan
    [J]. INDONESIAN JOURNAL OF CHEMISTRY, 2018, 18 (03) : 479 - 485
  • [32] Highly stable fibrous solid-state Ag/AgCl reference electrode
    Shen, Chaochao
    Xi, Xin
    Tang, Wei
    Guo, Xiaojun
    Liu, Ruili
    [J]. 2021 5TH IEEE ELECTRON DEVICES TECHNOLOGY & MANUFACTURING CONFERENCE (EDTM), 2021,
  • [33] Relation Between the SHE and the Internal Ag/AgCl Reference Electrode at High Temperatures
    Oijerholm, J.
    Forsberg, S.
    Hermansson, H-P.
    Ullberg, M.
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2009, 156 (03) : P56 - P61
  • [34] Microstructure, surface chemistry and electrochemical response of Ag|AgCl sensors in alkaline media
    Farhad Pargar
    Hristo Kolev
    Dessi A. Koleva
    Klaas van Breugel
    [J]. Journal of Materials Science, 2018, 53 : 7527 - 7550
  • [35] Microstructure, surface chemistry and electrochemical response of Ag|AgCl sensors in alkaline media
    Pargar, Farhad
    Kolev, Hristo
    Koleva, Dessi A.
    van Breugel, Klaas
    [J]. JOURNAL OF MATERIALS SCIENCE, 2018, 53 (10) : 7527 - 7550
  • [36] Design, Preparation and Performance Study of On-Chip Flow-Through Amperometric Sensors with an Integrated Ag/AgCl Reference Electrode
    Zhang, He
    Chuai, Rongyan
    Li, Xin
    Zhang, Bing
    [J]. MICROMACHINES, 2018, 9 (03):
  • [37] Fabrication and Characterisation of the Graphene Ring Micro Electrode (GRiME) with an Integrated, Concentric Ag/AgCl Reference Electrode
    Dickinson, James W.
    Bromley, Michael
    Andrieux, Fabrice P. L.
    Boxall, Colin
    [J]. SENSORS, 2013, 13 (03) : 3635 - 3651
  • [38] An integrated three-electrode system with a micromachined liquid-junction Ag/AgCl reference electrode
    Suzuki, H
    Hirakawa, T
    Sasaki, S
    Karube, I
    [J]. ANALYTICA CHIMICA ACTA, 1999, 387 (01) : 103 - 112
  • [39] Fabrication of a planar-form screen-printed solid electrolyte modified Ag/AgCl reference electrode for application in a potentiometric biosensor
    Liao, Wei-Yin
    Chou, Tse-Chuan
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (12) : 4219 - 4223
  • [40] Development of Integrated Planar Chloride Ion-Selective Electrode and Ag/AgCl Reference Electrode based on Chitosan/Cellulose Acetate Membrane for Blood Serum Analysis
    Alva, Sagir
    Hindasah, Euis
    Jamil, Wan Adil Wan
    Prasetyorini, Tri
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (12): : 1669 - 1686