Study on the ablation process and failure mechanism of the buffer layer in high-voltage XLPE cable

被引:0
|
作者
Tian, Yi [1 ,2 ]
Zhu, Guixin [1 ]
Miao, Qingqing [1 ]
Huang, Jiasheng [3 ]
Huang, Xinbo [1 ]
Li, Shengtao [2 ]
Li, Licheng [4 ]
机构
[1] Xian Polytech Univ, Dept Elect & Informat, Xian 710048, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R China
[3] Guangzhou Power Supply Bur Guangdong Power Grid Co, Guangzhou 510620, Peoples R China
[4] Elect Power Res Inst China Southern Power Grid, Guangzhou 510080, Peoples R China
来源
基金
中国博士后科学基金;
关键词
Buffer layer; Electric -thermal field coupling; Simulated ablation experiment; Characteristic gases;
D O I
10.1016/j.ijoes.2024.100662
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In recent years, the frequent occurrence of ablation faults in the buffer layers of high-voltage cross-linked polyethylene (XLPE) cables has significantly undermined the stability of power grid operations. However, existing research cannot fully explain the failure mechanism and transformation of related physical and chemical properties of high-voltage cable buffer layer. To address this, the paper have constructed an integrated analysis framework that includes multiphysics field simulations, an equivalent electrical network model, and simulated ablation experiments to comprehensively reveal the complete ablation failure mechanisms. Firstly, this study conducted a comparative analysis of the voltage distribution and temperature changes in the buffer layer using electro-thermal coupling simulations and an equivalent electrical network model. This analysis provides a detailed study of the dynamic development process of buffer layer ablation and identifies key electrical parameters. Subsequently, it verified the accuracy of the simulations through experiments on temperature variation characteristics, changes in hydrogen content, and other gas concentrations by constructing a simulated buffer layer ablation experimental platform. Finally, based on the study of the mechanisms of the buffer layer ablation failure process, this study divided it into three stages: initial electrochemical corrosion, appearance of white powder, and the onset of ablation discharge in the buffer layer. The comparison of experimental results with simulation data from the first two stages further validated the effectiveness and robustness of our analysis framework. In summary, this study provides a comprehensive analysis of the failure process in high-voltage cable buffer layers through simulation and experimental validation. This study provides a methodological basis for preventing cable ablation faults and detecting and evaluating the status of high-voltage XLPE cable buffer layers.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Analysis of influencing factors on buffer layer discharge for high-voltage XLPE cable
    Wu, Zhiheng
    Lai, Qingbo
    Zhou, Wenqing
    Liu, Xiaodong
    Chen, Jie
    Hu, Libin
    Hao, Yanpeng
    Liu, Gang
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2022, 16 (20) : 4142 - 4157
  • [2] The Lifetime Prediction and Insulation Failure Mechanism of XLPE for High-Voltage Cable
    Li, Guochang
    Wang, Zhaochen
    Lan, Rui
    Wei, Yanhui
    Nie, Yongjie
    Li, Shengtao
    Lei, Qingquan
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2023, 30 (02) : 761 - 768
  • [3] Study on Ablation between Metal Sheath and Buffer Layer of High Voltage XLPE Insulated Power Cable
    Jiang, Lei
    Xin, Yue
    Yan, Wenbo
    Zhao, Xiyuan
    Yao, Ruifeng
    Shen, Zhuoyuan
    Gao, Jinghui
    Zhong, Lisheng
    Wald, Detlef F.
    Ren, Zhigang
    [J]. 2019 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE 2019), 2019, : 372 - 375
  • [4] Failure investigation of buffer layers in high-voltage XLPE cables
    Chen, Yun
    Hui, Baojun
    Cheng, Yanting
    Hao, Yanpeng
    Fu, Mingli
    Yang, Lin
    Hou, Shuai
    Li, Licheng
    [J]. ENGINEERING FAILURE ANALYSIS, 2020, 113
  • [5] Distributed Optical Fiber Detection Based on BOTDR for Buffer Layer Defects of High-Voltage XLPE Cable With Corrugated Aluminum Sheath
    Cheng, Yanting
    Hao, Yanpeng
    Tian, Wanxing
    Zhao, Peng
    Tan, Haotian
    Li, Qishun
    Li, Licheng
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (04) : 1778 - 1787
  • [6] Breakpoint and Moisture Detection Method Based on Distributed Brillouin Optical Fiber Built in Buffer Layer of High-Voltage XLPE Cable
    Cheng, Yanting
    Hao, Yanpeng
    Li, Qishun
    Hui, Baojun
    Tian, Wanxing
    Tan, Haotian
    Chen, Linhao
    Li, Licheng
    [J]. IEEE SENSORS JOURNAL, 2024, 24 (02) : 1443 - 1452
  • [7] DEVELOPMENT OF XLPE-MOULDED JOINT FOR HIGH-VOLTAGE XLPE INSULATED CABLE
    OHATA, K
    KOJIMA, H
    SHIMOMURA, T
    ASAHI, K
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (07): : 1935 - 1941
  • [8] NEW HIGH-VOLTAGE XLPE CABLE CURING PROCESS-DEVELOPMENT AND ELECTRICAL CHARACTERISTICS
    YAMAUCHI, H
    KANEKO, R
    OKADA, M
    OTSUJI, M
    MATSUI, M
    SUGIYAMA, K
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1977, 96 (04): : 1062 - 1062
  • [9] High-Voltage Cable Buffer Layer Ablation Fault Identification Based on Artificial Intelligence and Frequency Domain Impedance Spectroscopy
    Liu, Jiajun
    Ma, Mingchao
    Liu, Xin
    Xu, Haokun
    [J]. SENSORS, 2024, 24 (10)
  • [10] Annealing Effects on XLPE Insulation of Retired High-Voltage Cable
    Xie, Yue
    Zhao, Yifeng
    Liu, Gang
    Huang, Jiasheng
    Li, Licheng
    [J]. IEEE ACCESS, 2019, 7 : 104344 - 104353