Evaluation of the Transfemoral Bone-Implant Interface Properties Using Vibration Analysis

被引:1
|
作者
Mohamed, Mostafa [1 ]
Beaudry, Eric [1 ]
Shehata, Ahmed W. [1 ,2 ,3 ]
Raboud, Donald [1 ]
Hebert, Jacqueline S. [2 ,3 ,4 ]
Westover, Lindsey [1 ,2 ,3 ]
机构
[1] Univ Alberta, Fac Engn, Dept Mech Engn, Edmonton, AB, Canada
[2] Univ Alberta, Fac Med, Dept Biomed Engn, Edmonton, AB, Canada
[3] Univ Alberta, Fac Med & Dent, Edmonton, AB, Canada
[4] Univ Alberta, Fac Med & Dent, Dept Med, Edmonton, AB, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Advanced system for implant stability testing; Bone-anchored implants; Transfemoral amputation; Vibration analysis; FREQUENCY-ANALYSIS; OSSEOINTEGRATION; STABILITY; RECONSTRUCTION; REHABILITATION; AMPUTEES; SYSTEM;
D O I
10.1007/s10439-024-03561-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Evaluating the bone-implant interface (BII) properties of osseointegrated transfemoral (TFA) implants is important for early failure detection and prescribing loads during rehabilitation. The objective of this work is to derive and validate a 1D finite element (FE) model of the Osseointegrated Prosthetic Limb (OPL) TFA system that can: (1) model its dynamic behaviour and (2) extract the BII properties. The model was validated by: (1) comparing the 1D FE formulation to the analytical and 3D FE solutions for a simplified cylinder, (2) comparing the vibration modes of the actual TFA geometry using 1D and 3D FE models, and (3) evaluating the BII properties for three extreme conditions (LOW, INTERMEDIATE, and HIGH) generated using 3D FE and experimental (where the implant was embedded, using different adhesives, in synthetic femurs) signals for additional validation. The modes predicted by the 1D FE model converged to the analytical and the 3D FE solutions for the cylinder. The 1D model also matched the 3D FE solution with a maximum frequency difference of 2.02% for the TFA geometry. Finally, the 1D model extracted the BII stiffness and the system's damping properties for the three conditions generated using the 3D FE simulations and the experimental INTERMEDIATE and HIGH signals. The agreement between the 1D FE and the 3D FE solutions for the TFA geometry indicates that the 1D model captures the system's dynamic behaviour. Distinguishing between the different BII conditions demonstrates the 1D model's potential use for the non-invasive clinical evaluation of the TFA BII properties.
引用
收藏
页码:2987 / 3008
页数:22
相关论文
共 50 条
  • [31] Osseointegration for transfemoral amputees: Influence of femur length and implant sizing on bone-implant contact and alignment
    Cao, Matthew
    Doherty, David B.
    He, Hongjia
    Vanodia, Vinay P.
    Reeves, Kristin
    Ismaily, Sabir K.
    Sauer, Jonathan J.
    Han, Shuyang
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2025, 56 (03):
  • [32] Biomechanical determinants of the stability of dental implants: Influence of the bone-implant interface properties
    Mathieu, Vincent
    Vayron, Romain
    Richard, Gilles
    Lambert, Gregory
    Naili, Salah
    Meningaud, Jean-Paul
    Haiat, Guillaume
    JOURNAL OF BIOMECHANICS, 2014, 47 (01) : 3 - 13
  • [33] Biomechanical Evaluation of Bone Quality Effect on Stresses at Bone-Implant Interface: A Finite Element Study
    Taharou, B.
    Merdji, A.
    Hillstrom, R.
    Benaissa, A.
    Roy, S.
    Della, N.
    Aid, A.
    Mukdadi, O. M.
    JOURNAL OF APPLIED AND COMPUTATIONAL MECHANICS, 2021, 7 (03): : 1266 - 1275
  • [34] Study with speckle interferometry of bone-implant interface conditions
    Simoes, J
    Monteiro, J
    Vaz, M
    Taylor, M
    Blatcher, S
    EXPERIMENTAL MECHANICS, VOLS 1 AND 2: ADVANCES IN DESIGN, TESTING AND ANALYSIS, 1998, : 851 - 855
  • [35] ELECTRON-MICROSCOPIC STUDY OF THE BONE-IMPLANT INTERFACE
    ROLAND, K
    DUFIEF, MP
    SHERIDAN, R
    HEUSON, JA
    MICRON AND MICROSCOPICA ACTA, 1987, 18 (03): : 209 - 209
  • [36] Effect of loading frequency on deformations at the bone-implant interface
    Xie, Shuqiao
    Manda, Krishnagoud
    Pankaj, Pankaj
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2019, 233 (12) : 1219 - 1225
  • [37] HISTOLOGY AT THE BONE-IMPLANT INTERFACE IN CEMENTED AND NONCEMENTED ENDOPROSTHESES
    HERREN, T
    REMAGEN, W
    SCHENK, R
    ORTHOPADE, 1987, 16 (03): : 239 - 251
  • [39] Titania nanotubes for orchestrating osteogenesis at the bone-implant interface
    Gulati, Karan
    Maher, Shaheer
    Findlay, David M.
    Losic, Dusan
    NANOMEDICINE, 2016, 11 (14) : 1847 - 1864
  • [40] In vitro assessment of bone-implant interface using an acoustic emission transmission test
    Ossi, Zannar
    Abdou, Wael
    Reuben, Robert L.
    Ibbetson, Richard J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2012, 226 (H1) : 63 - 69