Autoimmune Pancreatitis Surveillance: A Simplified MRI Protocol Versus a Comprehensive Pancreatic MRI Protocol

被引:2
|
作者
Liu, Jing-Yi [1 ]
Zhu, Liang [1 ]
Gao, Xin [1 ]
Li, Juan [1 ]
Sun, Zhao-Yong [1 ]
Jin, Zheng-Yu [1 ]
Xue, Hua-Dan [1 ]
机构
[1] Peking Union Med Coll & Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Radiol, Beijing, Peoples R China
关键词
Magnetic resonance imaging; Pancreas; Autoimmune pancreatitis; Surveillance; Simplified protocol;
D O I
10.1016/j.acra.2023.10.041
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Magnetic resonance imaging (MRI) has good diagnostic performance and causes no radiation damage, making it an ideal tool for the autoimmune pancreatitis (AIP) surveillance. However, its time cost is high. This study aimed to evaluate (1) whether a simplified protocol (SP) of MRI for AIP surveillance provides information equivalent to the comprehensive protocol (CP) and (2) the time cost reductions associated with using an SP. Materials and Methods: This retrospective single-institutional study included 40 patients with AIP with at least two contrast-enhanced MRI/magnetic resonance cholangiopancreatography studies. Two radiologists evaluated two imaging sets (CP/SP) per patient, independently. Intra- and inter-observer agreement in the evaluation of the pancreas and extrapancreatic organs involvement using the SP/CP in addition to the time cost differences between the SP and CP were assessed. Intra- and inter-rater reliability were assessed using Cohen's kappa test, intraclass correlations, or the weighted kappa test. The differences in time costs between the CP and SP were compared using the Mann-Whitney U test or Wilcoxon signed-rank test. Results: The SP had strong intra- and inter-observer agreement with the CP in evaluating MRI parameters (kappa > 0.60, moderate to excellent) and disease activity status (kappa > 0.80, all excellent). The overall image acquisition time cost for the SP was 49.2% of the CP. For the two radiologists, the image interpretation time cost of the SP was reduced by approximately 35% and 27% compared to the CP. Conclusion: For AIP surveillance, SP MRI provides information consistent with the CP and is less time-consuming.
引用
收藏
页码:1906 / 1917
页数:12
相关论文
共 50 条
  • [41] MRI Pattern in Autoimmune Pancreatitis Including Manganese Enhancement
    Feuerlein, S.
    Juchems, M.
    Brambs, H.
    Ernst, A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [42] MRCP and MRI findings in 9 patients with autoimmune pancreatitis
    Kamisawa, Terumi
    Pong-Yui Chen
    Yuyang Tu
    Nakajima, Hitoshi
    Egawa, Naoto
    Tsuruta, Kouji
    Okamoto, Atsutake
    Kamata, Noriko
    WORLD JOURNAL OF GASTROENTEROLOGY, 2006, 12 (18) : 2919 - 2922
  • [43] Brain MRI Protocol and Systematic Approach to Interpretation of Brain Tumors on MRI
    Loeber, Samantha
    VETERINARY CLINICS OF NORTH AMERICA-SMALL ANIMAL PRACTICE, 2025, 55 (01) : 11 - 21
  • [44] Incidental pancreatic cysts: natural history and diagnostic accuracy of a limited serial pancreatic cyst MRI protocol
    Stephanie Nougaret
    Caroline Reinhold
    Jaron Chong
    Laure Escal
    Gregoire Mercier
    Jean Michel Fabre
    Boris Guiu
    Nicolas Molinari
    European Radiology, 2014, 24 : 1020 - 1029
  • [45] Incidental pancreatic cysts: natural history and diagnostic accuracy of a limited serial pancreatic cyst MRI protocol
    Nougaret, Stephanie
    Reinhold, Caroline
    Chong, Jaron
    Escal, Laure
    Mercier, Gregoire
    Fabre, Jean Michel
    Guiu, Boris
    Molinari, Nicolas
    EUROPEAN RADIOLOGY, 2014, 24 (05) : 1020 - 1029
  • [46] The Role of MRI Pancreatic Protocol in Assessing Response to Neoadjuvant Therapy for Patients With Borderline Resectable Pancreatic Cancer
    Hussien, Nervana
    Hussien, Rasha S.
    Saad, Darine Helmy Amin
    El Kassas, Mohamed
    Elkhatib, Walid F.
    Ezz El Din, Mai
    FRONTIERS IN ONCOLOGY, 2022, 11
  • [47] State-of-the-art MRI Protocol for Comprehensive Assessment of Vocal Tract Structure and Function
    Lingala, Sajan Goud
    Toutios, Asterios
    Toger, Johannes
    Lim, Yongwan
    Zhu, Yinghua
    Kim, Yoon-Chul
    Vaz, Colin
    Narayanan, Shrikanth
    Nayak, Krishna
    17TH ANNUAL CONFERENCE OF THE INTERNATIONAL SPEECH COMMUNICATION ASSOCIATION (INTERSPEECH 2016), VOLS 1-5: UNDERSTANDING SPEECH PROCESSING IN HUMANS AND MACHINES, 2016, : 475 - 479
  • [48] Comprehensive echocardiographic protocol for pigs with emphasis on diastolic function: advantages over MRI assessment
    Naya, Nadia Martinez
    Sharp, Thomas E.
    Sgai, Manuela G.
    Capcha, Jose M. C.
    Shehadeh, Lina A.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2025, 328 (03): : H401 - H414
  • [49] A new and simplified comprehensive ultrasound protocol of haemophilic joints: the Universal Simplified Ultrasound (US-US) protocol
    Kandagaddala, M.
    Sundaramoorthy, M.
    Keshava, S. N.
    Gibikote, S.
    Mahata, K. M.
    Kavitha, M. L.
    Poonnoose, R.
    Srivastava, A.
    CLINICAL RADIOLOGY, 2019, 74 (11) : 897.e9 - 897.e16
  • [50] Accuracy of the ADNEX MR scoring system based on a simplified MRI protocol for the assessment of adnexal masses
    Pereira, Patrick N.
    Sarian, Luis O.
    Yoshida, Adriana
    Araujo, Karla G.
    Barros, Ricardo H. O.
    Baiao, Ana C.
    Parente, Daniella B.
    Derchain, Sophie
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2018, 24 (02) : 63 - 71