Relationship between ICD implantation volume and treatment parameters of patients receiving an ICD with remote monitoring

被引:0
|
作者
Butter, Christian [1 ,2 ]
Klein, Gunnar [3 ]
Groenefeld, Gerian [4 ]
Boecker, Dirk [5 ]
Suling, Anna [4 ]
Buchholz, Anika [6 ]
Felk, Angelika [7 ]
Hauser, Tino [7 ]
Wegscheider, Karl [6 ]
Baensch, Dietmar [8 ]
机构
[1] Heart Ctr Brandenburg Bernau, Dept Cardiol, Bernau, Germany
[2] Brandenburg Med Sch Theodor Fontane, Fac Hlth Sci Brandenburg, Bernau, Germany
[3] Heart Ctr Hannover, Clin Cardiol & Electrophysiol, Hannover, Germany
[4] Asklepios Clin Barmbek, Hamburg, Germany
[5] St Marien Hosp, Dept Cardiol, Hamm, Germany
[6] Univ Med Ctr Hamburg Eppendorf, Inst Med Biometry & Epidemiol, Hamburg, Germany
[7] BIOTRONIK, Berlin, Germany
[8] KMG Clin, Dept Rhythmol & Clin Electrophysiol, Gustrow, Germany
关键词
Defibrillators; implantable; cardiac resynchronization therapy; hospitals; high-volume; low-volume; home monitoring; CARDIOVERTER-DEFIBRILLATORS; FOLLOW-UP; EFFICACY; ASSOCIATION; SAFETY; TRIAL;
D O I
10.3233/THC-230641
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Both highly specialized heart centres and less specialized hospitals care for patients with implantable ICDs/CRT-Ds with remote monitoring. OBJECTIVE: To investigate potential differences in patient treatment according to centre's ICD implantation volume. METHODS: Based on their 2012 ICD/CRT-D implantation volume, centres enrolled in the NORDIC ICD trial in Germany were assigned to one of three groups: high- (HV, n = 345), medium- (MV, n = 340) or low-volume (LV, n = 189). RESULTS: The HV-centres had a significant higher CRT-D proportion (41.7%; LV: 36.5%; MV: 23.2%; P (global) < 0.001), significant shorter median procedure duration (49 min; MV: 58 min; LV: 60 min; P (global) < 0.001) but significant longer median hospital stay (4 days; MV and LV: 3 days; P (global) < 0.001) compared to MV- and LV-centres. The X-ray exposure was shorter in MV/HV-centres (MV: 3.4 min; HV: 3.6 min; LV: 5.5 min; P (global) < 0.001). Only 3.5% (LV: 2.6%; HV: 3.5%; MV: 4.1%) patients received at least one delivered inappropriate shock and 2.5% (HV: 2.0%; LV: 2.6%; MV: 2.9%) patients had withheld inappropriate ICD shocks without subsequent inappropriate shock delivery within 24.5 months of median follow-up. CONCLUSION: Implantation volume-dependent differences were observed in the device selection, procedure duration and x-ray exposure duration. Remote monitoring in combination with adequate response pattern prevented imminent inappropriate shocks in all three groups.
引用
下载
收藏
页码:1583 / 1593
页数:11
相关论文
共 50 条
  • [11] Patient satisfaction and suggestions for improvement of remote ICD monitoring
    Petersen, Helen Hogh
    Larsen, Mie Christa Jensen
    Nielsen, Olav Wendelboe
    Kensing, Finn
    Svendsen, Jesper Hastrup
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 34 (03) : 317 - 324
  • [12] Remote device monitoring and heart failure management of CRT-ICD patients
    Ricci, R.
    Landolina, M.
    Lunati, M.
    Perego, G. B.
    Marzegalli, M.
    Valsecchi, S.
    La Rocca, L.
    Santini, M.
    EUROPEAN HEART JOURNAL, 2008, 29 : 131 - 131
  • [13] ECONOMIC EVALUATION OF REMOTE MONITORING OF CRT/ICD THERAPY IN HEART FAILURE PATIENTS
    Riveros, B. S.
    Smala, A.
    Gongalves, V. F.
    Pedro, G.
    Rosim, M. P.
    Lucchetta, R. C.
    Nita, M. E.
    VALUE IN HEALTH, 2017, 20 (05) : A246 - A246
  • [14] Comparison of ICD Implantation in Obese and Nonobese Patients
    Venkataraman, Ganesh
    Mathur, Deepti
    Joshi, Siddhi
    Strickberger, Adam
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (04): : 481 - 485
  • [15] ICD Implantation in Patients with Nonischemic Heart Failure
    Stokes, Michael B.
    Roberts-Thomson, Kurt C.
    Teo, Karen S.
    NEW ENGLAND JOURNAL OF MEDICINE, 2017, 376 (01): : 90 - 91
  • [16] LEFT ATRIAL VOLUME: IS IT TIME TO RECONSIDER PRIMARY ICD IMPLANTATION?
    Bissolino, A.
    Gagliardi, M.
    Magnano, M.
    Mazzilli, S.
    Saglietto, A.
    Golzio, P.
    Budano, C.
    Castagno, D.
    Giustetto, C.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2019, 21 (0E) : E14 - E14
  • [17] Cerebral oxygen saturation monitoring in an infant undergoing ICD implantation
    de Vries, JW
    Hoorntje, T
    Bakker, PFA
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1998, 12 (04) : 442 - 444
  • [18] Differences in ICD implantation between women and men in Belgium
    Ingelaere, S.
    Hoffmann, R.
    Mairesse, G.
    de Waroux, J. -B. Le Polain
    Vijgen, J.
    Vandekerckhove, Y.
    Blankoff, I.
    Willems, R.
    ACTA CARDIOLOGICA, 2020, 75 (06) : 585 - 586
  • [19] Indications for ICD Implantation Differ Between Women and Men
    Ingelaere, Sebastian
    Hoffmann, Ruben
    Mairesse, Georges
    Vandekerckhove, Yves R.
    de Waroux, Jean-Benoit le Polain
    Vijgen, Johan
    Blankoff, Ivan
    Willems, Rik
    CIRCULATION, 2020, 142
  • [20] Pharmacological treatment of patients with HFrEF: is it really optimized in case of CRT and/or ICD implantation?
    Logeart, D.
    Isnard, R.
    Damy, T.
    Salvat, M.
    Eicher, J. C.
    Roubille, F.
    Tribouilloy, C.
    Bauer, F.
    Picard, F.
    Trochu, J. N.
    Roul, G.
    EUROPEAN HEART JOURNAL, 2019, 40 : 959 - 959