Load analysis for the development of a bonded edge seal for fluid-filled insulating glazing

被引:0
|
作者
Joachim, A. [1 ]
Weller, B. [1 ]
机构
[1] Tech Univ Dresden, Inst Bldg Construct, Dresden, Germany
关键词
D O I
10.1201/9781003348443-141
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Aesthetic and energy efficiency considerations play a decisive role in facade construction. In recent years, the use of fluids in pane cavities has been the subject of increased study, the aim being to satisfy the requirements of energy saving legislation. Such fluids are useful for transforming facades into multifunctional building envelopes. The combination of hydrostatic pressure and constant fluid contact places the edge seal of such glazing under considerable loads. For this reason, initial pilot projects could only be realised using mechanical clamping aids. However, this goes against the aesthetic requirements of modern glass facades, which strive to achieve a maximum proportion of glass while keeping the proportions of the frame to a minimum. The goal, therefore, is to develop a bonded edge seal for use in fluid-filled insulation glazing. This paper presents an overview of the state of the art regarding adhesive and sealing compounds in a fluid medium and fluid-filled facade elements. Followed by a potential edge seal design and the implementation of a load analysis. Adhesives used in an edge seal are exposed to physical, mechanical and chemical loads. This often leads to degradation processes in the polymers. This paper describes the impacts and classifies them according to the type of the ageing effect. All impacts are summarised in a load analysis. A load analysis forms the basis of both a list of requirements and a suitable test program.
引用
收藏
页码:860 / 865
页数:6
相关论文
共 50 条
  • [31] Vibration Analysis of Fluid-filled Pipes with Periodic Axial Supports
    周期支撑充液管路轴向振动特性分析
    Wu, Jianghai, 1600, Editorial office of Ship Building of China, China (61): : 136 - 143
  • [32] Modal Analysis of Vibrations in Fluid-filled Pipes of the Gas Generator
    Wei, Chao
    Deng, Changhua
    Xu, Yunfei
    PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING AND MECHANICS, VOLS 1 AND 2, 2009, : 982 - 986
  • [33] Wavelet analysis of sound signal in fluid-filled viscoelastic pipes
    Prek, M
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON FLUID STRUCTURE INTERACTION, AEROELASTICITY, FLOW INDUCED VIBRATION AND NOISE, PTS A AND B, 2002, : 871 - 879
  • [34] Coupling analysis of fluid-structure interaction in fluid-filled elbow pipe
    Xu, W. W.
    Wu, D. Z.
    Wang, L. Q.
    26TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS, PTS 1-7, 2013, 15
  • [35] On fluid-filled mixture model for suction pile foundation analysis
    Chen, Bang-Fuh
    Huang, Ting-ting
    OCEAN ENGINEERING, 2019, 188
  • [36] STATIC STABILITY AND PROPAGATION OF A FLUID-FILLED EDGE CRACK IN ROCK - IMPLICATION FOR FLUID TRANSPORT IN MAGMATISM AND METAMORPHISM
    NAKASHIMA, Y
    JOURNAL OF PHYSICS OF THE EARTH, 1993, 41 (03): : 189 - 202
  • [37] Dynamic Analysis of Fluid-Filled Piping System on Flexible Foundation
    Ren, Longlong
    Huang, Xiuchang
    Zhang, Zhengguo
    Hua, Hongxing
    SPECIAL TOPICS IN STRUCTURAL DYNAMICS, VOL 6, 34TH IMAC, 2016, : 155 - 164
  • [38] The dynamic response of a fluid-filled borehole under a normal point load on the free surface
    Ionov, Andrei M.
    GEOPHYSICAL PROSPECTING, 2013, 61 (01) : 104 - 119
  • [39] Analysis of vibration-isolation properties of fluid-filled perforated media
    Kowalski, S.J.
    Kuc, R.
    Musielak, C.
    Rozprawy Inzynierskie, 1988, 36 (04):
  • [40] ANALYSIS AND CORRECTION OF PRESSURE WAVE DISTORTION IN FLUID-FILLED CATHETER SYSTEMS
    FALSETTI, HL
    MATES, RE
    CARROLL, RJ
    GUPTA, RL
    BELL, AC
    CIRCULATION, 1974, 49 (01) : 165 - 172