Integration of Wearable Sensors and Electrical Muscle Stimulation in Lower Limb Robotics for Gait Rehabilitation

被引:0
|
作者
Malawade, Mandar [1 ]
Pervez, Mohammad Sohail [2 ]
Sahu, Anil [3 ]
Dhabliya, Dharmesh [4 ]
Vyas, Vibha [5 ]
Gandhi, Yatin [6 ]
机构
[1] Krishna Vishwa Vidyapeeth Deemed Univ, Krishna Coll Physiotherapy, Dept Paediat Neurosci, Karad, India
[2] Anjuman Coll Engn & Technol, Mech Engn Dept, Nagpur, India
[3] GH Raisoni Coll Engn & Management, Pune, India
[4] Vishwakarma Inst Informat Technol, Dept Informat Technol, Pune, Maharashtra, India
[5] COEP Technol Univ, Dept Elect & Telecommun, Pune, Maharashtra, India
[6] Competent Softwares, Pune, Maharashtra, India
关键词
Wearable sensors; Electrical muscle stimulation; Lower limb robotics; Gait rehabilitation; Neurological impairments; STEREOPHOTOGRAMMETRY; TRACKING; MODEL;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Combining wearing devices with electrical muscle stimulation (EMS) in robotic lower limbs has shown promise in helping people learn how to walk again. This new method blends the benefits of smart technology and EMS to help people with neurological or joint problems improve their motor function and walking patterns. Wearable devices, like inertial measurement units (IMUs) and electromyography (EMG) monitors, record information about how the body moves and what muscles are doing while the person moves. These monitors give the user and the therapy team feedback in real time, which makes it possible for personalized and flexible recovery plans. Data from personal monitors can also be used to look at how people walk and see how they're doing over time. EMS is used to target certain muscles and make them stronger, more coordinated, and easier to control. By combining EMS with robots for the lower limbs, therapists can focus on certain muscle groups and make recovery routines more successful. EMS can also be timed to move with the robotic suit to help the person walk in a more natural and useful way. Wearable sensors and EMS work well together in lower limb robots for many reasons. EMS therapy can be made more specific and flexible because wearing monitors let doctors change the frequency and strength of the therapy in real time. The person is also encouraged to be more involved with this method because they get instant feedback on their actions and can see how they're doing over time. The combining wearing sensors and EMS in lower limb robots has a lot of promise to make gait therapy work better. Future study should focus on finding the best ways to combine these tools and looking at how they affect the quality of life and ability to walk for people who have movement problems in the long run.
引用
收藏
页码:999 / 1009
页数:11
相关论文
共 50 条
  • [1] Lower limb rehabilitation system controlled by robotics, electromyography surface and functional electrical stimulation
    Patino, Juan G.
    Bravo, E. E.
    Perez, Jairo J.
    Perez, Vera
    [J]. 2013 PAN AMERICAN HEALTH CARE EXCHANGES (PAHCE), 2013,
  • [2] Robotics for Lower Limb Rehabilitation
    Esquenazi, Alberto
    Talaty, Mukul
    [J]. PHYSICAL MEDICINE AND REHABILITATION CLINICS OF NORTH AMERICA, 2019, 30 (02) : 385 - +
  • [3] Wearable lower limb robotics: A review
    Viteckova, Slavka
    Kutilek, Patrik
    Jirina, Marcel
    [J]. BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2013, 33 (02) : 96 - 105
  • [4] Rehabilitation robotics and wearable sensors as trends of home rehabilitation
    Jobbagy, Boris
    Karchnak, Jan
    Simsik, Dusan
    [J]. 2014 15TH INTERNATIONAL CARPATHIAN CONTROL CONFERENCE (ICCC), 2014, : 219 - 222
  • [5] Gait asymmetrical evaluation of lower limb amputees using wearable inertial sensors
    Maqbool, Hafiz Farhan
    Mahmood, Imran
    Ali, Ahmad
    Iqbal, Nadeem
    Seong, Jin-Taek
    Dehghani-Sanij, Abbas Ali
    Alaziz, Sundas Naji
    Awad, Mohammed Ibrahim
    [J]. HELIYON, 2024, 10 (12)
  • [6] Lower Limb Gait Activity Recognition Using Inertial Measurement Units for rehabilitation robotics
    Hamdi, Mohammed M.
    Awad, Mohammed I.
    Abdelhameed, Magdy M.
    Tolbah, Farid A.
    [J]. PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS (ICAR), 2015, : 316 - 322
  • [7] Functional electrical stimulation (FES) for lower limb paralysis rehabilitation
    Ring, H.
    [J]. PROCEEDINGS OF THE 9TH CONGRESS OF THE EUROPEAN FEDERATION FOR RESEARCH IN REHABILITATION, 2007, : 33 - 41
  • [8] A Wearable Multimode System with Soft Sensors for Lower Limb Activity Evaluation and Rehabilitation
    Bao, Shenjie
    Yin, Shubao
    Chen, Hongyu
    Chen, Wei
    [J]. 2018 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC): DISCOVERING NEW HORIZONS IN INSTRUMENTATION AND MEASUREMENT, 2018, : 1761 - 1766
  • [9] Research on the Lower Limb Gait Rehabilitation
    Wang, Hongbo
    Wu, Jianshuang
    Wang, Yubo
    Ren, Lingxue
    Zhang, Dong
    Lu, Hao
    [J]. 2014 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2014), 2014, : 1243 - 1247
  • [10] EMERGING DIRECTIONS IN LOWER LIMB EXTERNALLY WEARABLE ROBOTS FOR GAIT REHABILITATION AND AUGMENTATION - A REVIEW
    Veneman, Jan F.
    Burdet, Etienne
    van der Kooij, Herman
    Lefeber, Dirk
    [J]. ADVANCES IN COOPERATIVE ROBOTICS, 2017, : 840 - 850