Gait variability, fractal dynamics, and statistical regularity of treadmill and overground walking recorded with a smartphone

被引:0
|
作者
Di Bacco, Vincenzo E. [1 ,2 ]
Gage, William H. [1 ]
机构
[1] York Univ, Sch Kinesiol & Hlth Sci, Toronto, ON, Canada
[2] York Univ, Sherman Hlth Sci Res Ctr 2020, Orthopaed Neuromech Lab, 4700 Keele St, Toronto, ON M3J 1P3, Canada
关键词
Fractal; Entropy; Variability; Nonlinear gait dynamics; Wearables; Smartphone accelerometer; LONG-RANGE CORRELATIONS; STRIDE-INTERVAL; KINEMATIC VARIABILITY; STABILITY; RELIABILITY; PARAMETERS; SPEED; BODY;
D O I
10.1016/j.gaitpost.2024.04.002
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: The nonlinear variability present during steady-state gait may provide a signature of health and showcase one's walking adaptability. Although treadmills can capture vast amounts of walking data required for estimating variability within a small space, gait patterns may be misrepresented compared to an overground setting. Smartphones may provide a low-cost and user-friendly estimate of gait patterns among a variety of walking settings. However, no study has investigated differences in gait patterns derived from a smartphone between treadmill walking (TW) and overground walking (OW). Research question: This study implemented a smartphone accelerometer to compare differences in temporal gait variability and gait dynamics between TW and OW. Methods: Sixteen healthy adults (8F; 24.7 +/- 3.8 years) visited the laboratory on three separate days and completed three 8-minute OW and three TW trials, at their preferred speed, during each visit. The inter-stride interval was calculated as the time difference between right heel contact events located within the vertical accelerometery signals recorded from a smartphone while placed in participants front right pant pocket during walking trials. The inter-stride interval series was used to calculate stride time standard deviation (SD) and coefficient of variation (COV), statistical persistence (fractal scaling index), and statistical regularity (sample entropy). Two-way analysis of variance compared walking condition and laboratory visits for each measure. Results: Compared to TW, OW displayed significantly (p < 0.01) greater stride time SD (0.014 s, 0.020 s), COV (1.26 %, 1.82 %), fractal scaling index (0.70, 0.79) and sample entropy (1.43, 1.63). No differences were found between visits for all measures. Significance: Smartphone-based assessment of gait provides the ability to distinguish between OW and TW conditions, similar to previously established methodologies. Furthermore, smartphones may be a low-cost and user-friendly tool to estimate gait patterns outside the laboratory to improve ecological validity, with implications for free-living monitoring of gait among various populations.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [31] Automated quantification and comparison of spatio-temporal gait parameters during treadmill and overground walking
    Betker, Aimee L.
    Maharjan, Pramila
    Yaduvanshi, Chandrashekhar
    Szturm, Tony
    Moussavi, Zahra
    2008 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-4, 2008, : 158 - +
  • [32] Comparison of Underwater and Overground Treadmill Walking to Improve Gait Pattern and Muscle Strength after Stroke
    Park, Si-Eun
    Kim, Soon-Hee
    Lee, Sang-Bin
    An, Ho-Jung
    Choi, Wan-Suk
    Moon, Ok-Gon
    Kim, Ji-Sung
    Shin, Hee-Joon
    Choi, Yoo-Rim
    Min, Kyoung-Ok
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2012, 24 (11) : 1087 - 1090
  • [33] Gait variability in younger and older adult women is altered by overground walking protocol
    Paterson, Kade L.
    Lythgo, Noel D.
    Hill, Keith D.
    AGE AND AGEING, 2009, 38 (06) : 745 - 748
  • [34] Comparing spatiotemporal gait parameters between overground walking and self-paced treadmill walking in persons after stroke
    Van Bladel, Anke
    De Ridder, Roel
    Palmans, Tanneke
    Van der Looven, Ruth
    Cambier, Dirk
    DISABILITY AND REHABILITATION, 2023, 45 (06) : 1016 - 1021
  • [35] Treadmill walking increases average mask variability of in-shoe plantar foot loading compared to overground walking
    Apps C.
    Weston H.
    Sterzing T.
    Footwear Science, 2019, 11 (sup1) : S209 - S210
  • [36] Effect of treadmill walking on the stride interval dynamics of human gait
    Chang, Matthew D.
    Shaikh, Sameer
    Chau, Tom
    GAIT & POSTURE, 2009, 30 (04) : 431 - 435
  • [37] Fractal dynamics and gait adaptability during asymmetrical walking
    Ducharme, Scott W.
    Liddy, Joshua J.
    Haddad, Jeffrey M.
    Busa, Michael A.
    Claxton, Laura J.
    Van Emmerik, Richard E. A.
    JOURNAL OF SPORT & EXERCISE PSYCHOLOGY, 2016, 38 : S59 - S59
  • [38] Improvement in Overground Walking After Treadmill-Based Gait Training in a Child With Agenesis of the Corpus Callosum
    Henderson, Gena
    Beerse, Matthew
    Liang, Huaqing
    Ferreira, Diego
    Wu, Jianhua
    PHYSICAL THERAPY, 2020, 100 (01): : 157 - 167
  • [39] Variability of Spatiotemporal Gait Kinematics During Treadmill Walking: Is There a Hawthorne Effect?
    Farhan, Saaniya
    Avalos, Marco A.
    Rosenblatt, Noah J.
    JOURNAL OF APPLIED BIOMECHANICS, 2023, 39 (03) : 151 - 156
  • [40] Treadmill Interface for Virtual Reality vs. Overground Walking: A Comparison of Gait in Individuals with and without Pain
    Powell, Wendy
    Stevens, Brett
    Simmonds, Maureen
    CYBERPSYCHOLOGY & BEHAVIOR, 2009, 12 (05): : 645 - 646