Performance study of scroll compressor based on the impact of non-return valve integrated

被引:0
|
作者
Ma, Xuelian [1 ,4 ]
Fang, Yue [1 ]
Ye, Hang [2 ]
Zou, Hongfu [3 ]
Yang, Junlan [1 ,4 ]
Li, Yifan [1 ]
机构
[1] Tianjin Chengjian Univ, Sch Energy & Safety Engn, Tianjin 300384, Peoples R China
[2] Danfoss Tianjin Co Ltd, Tianjin 301700, Peoples R China
[3] Tianjin Emaging Technol Co Ltd, Tianjin 300350, Peoples R China
[4] 26 Jinjing Rd, Tianjin, Peoples R China
关键词
Compressor performance; Non-return valve integrated; NRVI; CFD; SOURCE HEAT-PUMP; SINGLE-STAGE; ENERGY; WATER;
D O I
10.1016/j.applthermaleng.2024.123405
中图分类号
O414.1 [热力学];
学科分类号
摘要
Non -return valve is a common component in refrigeration system, it ' s called non -return valve integrated (NRVI) when it is assembled at the discharge port of compressor. NRVI works in a very complicated environment, including high temperature, high pressure, discharge pulse, gas - liquid two phases, etc. This paper focuses on the performance impact to compressor by NRVI related factors, including the housing internal flow distribution, valve head geometry, variable refrigerants and working conditions, compressor models and power frequency, spring stiffness and opening rate etc. CFD method is used to simulate different situations, finally we got the conclusion of compressor performance impact from NRVI, the optimization design suggestions were given too.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Simulation and experimental studies of a non-return valve performance during injection molding
    Zook, C
    Isayev, AI
    ANTEC '99: PLASTICS BRIDGING THE MILLENNIA, CONFERENCE PROCEEDINGS, VOLS I-III: VOL I: PROCESSING; VOL II: MATERIALS; VOL III: SPECIAL AREAS;, 1999, : 427 - 431
  • [2] Incorrect assembly of non-return valve of an Oxylog ventilator
    Thomas, RC
    Kuppurao, L
    ANAESTHESIA, 2005, 60 (02) : 209 - 210
  • [3] Flow Performance Analysis of Non-Return Multi-Door Reflux Valve: Experimental Case Study
    Hadebe, Xolani Prince
    Kouejou, Bernard Xavier Tchomeni
    Alugongo, Alfayo Anyika
    Sozinando, Desejo Filipeson
    FLUIDS, 2024, 9 (09)
  • [4] MULTIWAY NON-RETURN VALVE FOR USE IN PHYSIOLOGICAL EXPERIMENTS
    HOLDER, RED
    SATTELLE, DB
    JOURNAL OF PHYSIOLOGY-LONDON, 1972, 226 (02): : P2 - &
  • [5] Non-return valve with distributive and dispersive mixing capability
    Rauwendaal, C
    ANTEC 2000: SOCIETY OF PLASTICS ENGINEERS TECHNICAL PAPERS, CONFERENCE PROCEEDINGS, VOLS I-III, 2000, : 638 - 641
  • [6] How to tell if your non-return valve is leaking
    Bozzelli, John
    Plastics Technology, 2014, 60 (11) : 32 - 34
  • [7] A NON-RETURN VALVE FOR CONTINUOUS USE WITH EMERSON POSTOPERATIVE VENTILATOR
    BERRY, PR
    PONTOPPI.H
    ANESTHESIOLOGY, 1968, 29 (04) : 828 - &
  • [8] Incorrect assembly of non-return valve of an Oxylog ventilator - Reply
    Redpath, MS
    ANAESTHESIA, 2005, 60 (02) : 210 - 211
  • [9] Study of dynamic behaviour of non-return valves
    Francois, P
    HYDRAULIC MACHINERY AND CAVITATION, VOLS I AND II, 1996, : 494 - 503
  • [10] Monitoring of Non-Return Valve Operation with a Variable-Speed Drive
    Ahonen, Tero
    Tamminen, Jussi
    Ahola, Jero
    Saukko, Juha
    2015 17TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'15 ECCE-EUROPE), 2015,