Application of Energy-Dispersive X-ray Spectroscopy to Quantify the Chemical Composition of Igneous Rocks

被引:0
|
作者
Pechenkina, E. N. [1 ]
Krenev, V. A. [1 ]
Fomichev, S. V. [1 ]
Kondakov, D. F. [1 ]
Berbekova, E. I. [1 ]
Mikhailov, A. A. [1 ]
机构
[1] Russian Acad Sci, Kurnakov Inst Gen & Inorgan Chem, Moscow 119991, Russia
关键词
EDS; gabbro; basalt; basaltic andesite; dolerite; anorthosite; RARE-EARTH-ELEMENTS;
D O I
10.1134/S0036023623700365
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The possibility of using energy-dispersive X-ray spectroscopy for quantification of the chemical composition of igneous rocks without their transfer into solution has been considered. Statistical processing of the measurement results has been carried out, and the error of the method in comparison with the inductively coupled plasma spectrometry method has been demonstrated.
引用
收藏
页码:234 / 239
页数:6
相关论文
共 50 条
  • [31] Diagnosis of electrocution: The application of scanning electron microscope and energy-dispersive X-ray spectroscopy in five cases
    Visona, S. D.
    Chen, Y.
    Bernardi, P.
    Andrello, L.
    Osculati, A.
    FORENSIC SCIENCE INTERNATIONAL, 2018, 284 : 107 - 116
  • [32] CHEMICAL AND ENERGY-DISPERSIVE X-RAY ANALYSES OF GUTTA-PERCHA POINTS
    MOLLER, B
    ORSTAVIK, D
    JOURNAL OF ENDODONTICS, 1984, 10 (09) : 413 - 416
  • [33] Composition analysis of different particle formations from laser ablation by energy-dispersive x-ray spectroscopy.
    Hedges, A
    Alexander, ML
    Mendoza, A
    Young, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U361 - U361
  • [34] Synchrotron energy-dispersive X-ray diffraction tomography
    Hall, C
    Barnes, P
    Cockcroft, JK
    Colston, SL
    Hausermann, D
    Jacques, SDM
    Jupe, AC
    Kunz, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 140 (1-2): : 253 - 257
  • [35] OPTIMUM RESOLUTION IN X-RAY ENERGY-DISPERSIVE DIFFRACTOMETRY
    BURAS, B
    NIIMURA, N
    OLSEN, JS
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1978, 11 (APR) : 137 - 140
  • [36] Measuring performance of energy-dispersive X-ray systems
    Statham, PJ
    MICROSCOPY AND MICROANALYSIS, 1998, 4 (06) : 605 - 615
  • [37] The optimization of an energy-dispersive X-ray diffraction system for potential clinical application
    Chaparian, A.
    Oghabian, M. A.
    Changizi, V.
    Farquharson, M. J.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (12) : 2237 - 2245
  • [38] X-RAY FLUOROMETRY (ENERGY-DISPERSIVE) - APPLICATION TO THE ANALYSIS OF METALLIC POLLUTANTS IN WATER
    VAZQUEZ, C
    ANALES DE LA ASOCIACION QUIMICA ARGENTINA, 1994, 82 (02): : 91 - 96
  • [39] Gauge of an energy-dispersive X-ray fluorescence analyzer
    Bukin, KV
    Nakhabtsev, VS
    Romanova, NE
    Kirillov, VN
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1998, 41 (03) : 393 - 397
  • [40] FOCUSING X-RAY POLARIZER FOR ENERGY-DISPERSIVE ANALYSIS
    ONG, PS
    RANDALL, JN
    X-RAY SPECTROMETRY, 1978, 7 (04) : 241 - 248