Multicenter Quantification of Radiation Exposure and Associated Risks for Prostatic Artery Embolization in 1476 Patients

被引:0
|
作者
Ayyagari, Raj [1 ]
Rahman, Saumik Z. [2 ]
Grizzard, Kevin [2 ]
Mustafa, Adel [2 ]
Staib, Lawrence H. [2 ]
Makkia, Rasha S. [2 ]
Bhatia, Shivank [3 ]
Bilhim, Tiago [4 ]
Carnevale, Francisco C. [5 ]
Davis, Clifford [6 ]
Fischman, Aaron [7 ]
Isaacson, Ari [8 ]
McClure, Timothy [9 ]
McWilliams, Justin [10 ]
Nutting, Charles [11 ]
Richardson, Andrew [3 ]
Salem, Riad [12 ]
Sapoval, Marc [13 ]
Yu, Hyeon [14 ]
机构
[1] Boston Med Ctr, 75 Albany St, Boston, MA 02118 USA
[2] Yale Univ, Sch Med, New Haven, CT USA
[3] Univ Miami, Miller Sch Med, Miami, FL 33136 USA
[4] Ctr Hosp Univ Lisboa Cent, Lisbon, Portugal
[5] Univ Sao Paulo, Fac Med, Sao Paulo, Brazil
[6] Univ S Florida, Morsani Coll Med, Tampa, FL USA
[7] Icahn Sch Med Mt Sinai, New York, NY 10029 USA
[8] Prostate Ctr USA, Raleigh, NC USA
[9] Weill Cornell Med Coll, New York, NY USA
[10] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA USA
[11] Endovasc Consultants Colorado, Boulder, CO 80309 USA
[12] Northwestern Univ, Feinberg Sch Med, Evanston, IL 60208 USA
[13] Hop Europeen Georges Pompidou, AP HP, Paris, France
[14] Univ North Carolina Chapel Hill, Sch Med, Chapel Hill, NC USA
关键词
D O I
10.1148/radiol.231877
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Prostatic artery embolization (PAE) is a safe, minimally invasive angiographic procedure that effectively treats benign prostatic hyperplasia; however, PAE-related patient radiation exposure and associated risks are not completely understood. Purpose: To quantify radiation dose and assess radiation-related adverse events in patients who underwent PAE at multiple centers. Materials and Methods: This retrospective study included patients undergoing PAE for any indication performed by experienced operators at 10 high-volume international centers from January 2014 to May 2021. Patient characteristics, procedural and radiation dose data, and radiation-related adverse events were collected. Procedural radiation effective doses were calculated by multiplying kerma-area product values by an established conversion factor for abdominopelvic fluoroscopy-guided procedures. Relationships between cumulative air kerma (CAK) or effective dose and patient body mass index (BMI), fluoroscopy time, or radiation field area were assessed with linear regression. Differences in radiation dose stemming from radiopaque prostheses or fluoroscopy unit type were assessed using two-sample t tests and Wilcoxon rank sum tests. Results: A total of 1476 patients (mean age, 69.9 years +/- 9.0 [SD]) were included, of whom 1345 (91.1%) and 131 (8.9%) underwent the procedure with fixed interventional or mobile fluoroscopy units, respectively. Median procedure effective dose was 17.8 mSv for fixed interventional units and 12.3 mSv for mobile units. CAK and effective dose both correlated positively with BMI (R-2 = 0.15 and 0.17; P < .001) and fluoroscopy time (R-2 = 0.16 and 0.08; P < .001). No radiation-related 90-day adverse events were reported. Patients with radiopaque implants versus those without implants had higher median CAK (1452 mGy [range, 900-2685 mGy] vs 1177 mGy [range, 700-1959 mGy], respectively; P = .01). Median effective dose was lower for mobile than for fixed interventional systems (12.3 mSv [range, 8.5-22.0 mSv] vs 20.4 mSv [range, 13.8-30.6 mSv], respectively; P < .001). Conclusion: Patients who underwent PAE performed with fixed interventional or mobile fluoroscopy units were exposed to a median effective radiation dose of 17.8 mSv or 12.3 mSv, respectively. No radiation-related adverse events at 90 days were reported.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Patient radiation dose associated with uterine artery embolization
    Nikolic, B
    Spies, JB
    Lundsten, MJ
    Abbara, S
    RADIOLOGY, 2000, 214 (01) : 121 - 125
  • [22] Quantification of Radiation Exposure in Trauma Patients
    Wagner, Michel
    Vonk, Jonathon
    Wichman, Chris
    Hegde, Ashwin
    Oliveto, Jennifer
    CRITICAL CARE MEDICINE, 2013, 41 (12)
  • [23] Virtual Injection Software Reduces Radiation Exposure and Procedural Time of Prostatic Artery Embolization Performed with Cone-Beam CT
    Barral, Matthias
    Lassalle, Louis
    Gardavaud, Francois
    Lehrer, Raphael
    Haffaf, Idriss
    Agbonon, Remi
    Cussenot, Olivier
    Cornelis, Francois H.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2024, 35 (03) : 409 - 415
  • [24] Center experience and other determinants of patient radiation exposure during prostatic artery embolization: a retrospective study in three Scandinavian centers
    Svarc, Petra
    Hagen, Thijs
    Waltenburg, Hanne
    Andersson, Christian
    Blackberg, Mats
    Baco, Eduard
    Taudorf, Mikkel
    Roder, Martin Andreas
    Lindgren, Hans
    Klow, Nils-Einar
    Loenn, Lars Birger
    EUROPEAN RADIOLOGY, 2022, 32 (04) : 2404 - 2413
  • [25] Prostatic Artery Embolization: Influence of Cone-Beam Computed Tomography on Radiation Exposure, Procedure Time, and Contrast Media Use
    Burckenmeyer, F.
    Diamantis, I.
    Kriechenbauer, T.
    Lehmann, T.
    Franiel, T.
    Malouhi, A.
    Grimm, M. O.
    Teichgraber, U.
    Aschenbach, R.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2021, 44 (07) : 1089 - 1094
  • [26] Two-Year Outcomes of Prostatic Artery Embolization for Symptomatic Benign Prostatic Hyperplasia: An International, Multicenter, Prospective Study
    Sapoval, Marc R.
    Bhatia, Shivank
    Dean, Carole
    Rampoldi, Antonio
    Carnevale, Francisco Cesar
    Bent, Clare
    Tapping, Charles R.
    Bongiovanni, Simone
    Taylor, Jeremy
    Brower, Jayson S.
    Rush, Michael
    Mcwilliams, Justin P.
    Little, Mark W.
    Pellerin, Olivier
    Barbosa, Fabiane
    Borghei, Peyman
    Gin, Greg E.
    Uchio, Edward
    Plotnik, Adam N.
    Briggs, James H.
    Macdonald, Andrew
    Tummala, Srini
    Shah, Hemendra Navinchandra
    Kably, Issam M.
    Pereira, Keith
    Katrivesis, James
    Ng, Keng Lim
    Vaheesan, Kirubahara
    Behdad, Mina
    Macgill, Sarah
    Crosbie, Sarah
    Gavrila, Madita
    Anthony, Susan
    Quezada, Lia
    Aleman, Ricardo
    Ferguson, Cynthia Toot
    Ahmed-Timms, Far
    Edwards, Alexandra
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2024, : 1515 - 1524
  • [27] Center experience and other determinants of patient radiation exposure during prostatic artery embolization: a retrospective study in three Scandinavian centers
    Petra Svarc
    Thijs Hagen
    Hanne Waltenburg
    Christian Andersson
    Mats Bläckberg
    Eduard Baco
    Mikkel Taudorf
    Martin Andreas Røder
    Hans Lindgren
    Nils-Einar Kløw
    Lars Birger Lönn
    European Radiology, 2022, 32 : 2404 - 2413
  • [28] Prostatic Artery Embolization: Influence of Cone-Beam Computed Tomography on Radiation Exposure, Procedure Time, and Contrast Media Use
    F. Bürckenmeyer
    I. Diamantis
    T. Kriechenbauer
    T. Lehmann
    T. Franiel
    A. Malouhi
    M. O. Grimm
    U. Teichgräber
    R. Aschenbach
    CardioVascular and Interventional Radiology, 2021, 44 : 1089 - 1094
  • [29] Clinical Outcomes of Prostatic Artery Embolization in Patients with Benign Prostatic Hyperplasia: A Prospective Clinical Study
    Dogan, Kazim
    Erbagci, Ahmet
    Sen, Haluk
    Kervancioglu, Selim
    Erturhan, Mehmet Sakip
    Seckiner, Ilker
    Bayrak, Omer
    TURKISH JOURNAL OF UROLOGY, 2022, 48 (03): : 215 - 221
  • [30] Prostatic artery embolization for high surgical risk patients in refractory retention
    Cheng, K. C.
    Yu, S. M.
    Yu, H. T.
    Ngo, C. C.
    Chan, H. C.
    Chan, C. S.
    So, H. S.
    BJU INTERNATIONAL, 2019, 123 : 5 - 5