COMPARATIVE ANALYSIS OF DIRECT AND INDIRECT COOLING OF WIDE-BANDGAP POWER MODULES AND PERFORMANCE ENHANCEMENT OF JET IMPINGEMENT-BASED DIRECT SUBSTRATE COOLING

被引:0
|
作者
Barua, Himel [1 ]
Gurpinar, Emre [1 ]
Xue, Lingxiao [1 ]
Ozpineci, Burak [1 ]
机构
[1] Oak Ridge Natl Lab, Bldg & Transportat Sci Div, Oak Ridge, TN 37830 USA
关键词
Wide-bandgap device; direct substrate cooling; jet impingement; THERMAL MANAGEMENT; HEAT-TRANSFER; NOZZLE GEOMETRY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the development of high-power and high-torque machines, requirements for high-power density electronics are increasing. Thermal management of such systems requires high heat extraction. Conventional air cooling based heat sinks and cold plate based liquid cooling have their own benefits for various applications but has limitations for high power density applications. The current study explores a jet impingement based direct substrate cooling system that was implemented for a SiC based direct bonded Cu substrate for various power losses. Numerical comparison between jet impingement cooling and conventional horizontal/indirect cooling (pin fin heat sink and genetic algorithm- optimized heat sink) showed that the area weighted average of the heat transfer coefficient (HTC) is high for both horizontal cooling designs, and the local HTC is higher for jet impingement. Design iterations were undertaken to resolve the bottleneck of this cooling system. Increasing the number of nozzles helped to cover more area at the direct bonded Cu bottom plate, which drops the chip temperature considerably. With a constant flow rate, increasing the number of nozzles would decrease local jet velocity, which reduces the heat extraction by jet impingement. This issue can be addressed by reducing the diameter of nozzle but doing so results in a high pressure drop where the design constraint is 2 psi. A flared nozzle design is proposed, which has a higher spreading angle of the jet that increases the flow coverage and reduces the pressure drop of the coolant loop.
引用
收藏
页数:11
相关论文
共 31 条
  • [21] EXPERIMENTAL CHARACTERIZATION OF CONFINED, PACKAGE-LEVEL DIRECT TWO-PHASE JET IMPINGEMENT COOLING WITH MICRO-PIN FIN SURFACE ENHANCEMENT
    Wu, Qianying
    Gong, Zheng
    Chan, Chih-Yao
    Kwon, Heungdong
    Goodson, Ken
    Wei, Tiwei
    PROCEEDINGS OF ASME 2023 INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, INTERPACK2023, 2023,
  • [22] Comparative performance analysis of direct and desiccant assisted evaporative cooling systems using novel candidate materials
    Khosravi, Nima
    Aydin, Devrim
    Nejhad, Majid Karim
    Dogramaci, Pervin Abohorlu
    ENERGY CONVERSION AND MANAGEMENT, 2020, 221
  • [23] Numerical analysis-based performance prediction in a direct evaporative cooler used for building cooling
    Salins, Sampath Suranjan
    Kumar, Shiva
    Kartik, Ritu Kiran
    Reddy, S. V. Kota
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2022, 15 (02) : 237 - 250
  • [24] THERMODYNAMIC PERFORMANCE ANALYSIS OF A NEW CHP SYSTEM WITH ABSORPTION HEAT PUMP IN A DIRECT AIR COOLING POWER PLANT
    Zhang, Hongsheng
    Zhao, Hongbin
    Li, Zhenlin
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2015, VOL 6A, 2016,
  • [25] Model-based thermodynamic analysis of direct air capture units in repurposed power plant cooling towers
    Sager, Robert
    Pehle, Lukas
    Petersen, Nils Hendrik
    Wirsum, Manfred
    Hannes, Jens
    APPLIED ENERGY, 2025, 378
  • [26] Advanced (Metal 3D-Printed) Direct Liquid Jet-Impingement Cooling Solution for Autonomous Driving High-Performance Vehicle Computer (HPVC)
    Pappaterra, Antonio
    Vandevelde, Bart
    Nazemi, Majid
    Verleysen, Willem
    Oprins, Herman
    2021 22ND INTERNATIONAL CONFERENCE ON THERMAL, MECHANICAL AND MULTI-PHYSICS SIMULATION AND EXPERIMENTS IN MICROELECTRONICS AND MICROSYSTEMS (EUROSIME), 2021,
  • [27] Hybrid modeling-based digital twin for performance optimization with flexible operation in the direct air-cooling power unit
    Zhao, Guanjia
    Cui, Zhipeng
    Xu, Jing
    Liu, Wenhao
    Ma, Suxia
    ENERGY, 2022, 254
  • [28] Effect analysis on integration efficiency and safety performance of a battery thermal management system based on direct contact liquid cooling
    Wu, Shangquan
    Lao, Li
    Wu, Lin
    Liu, Lei
    Lin, Chunjing
    Zhang, Qingchuan
    APPLIED THERMAL ENGINEERING, 2022, 201
  • [29] Impacts of Local Cooling Technologies on Air Cooled Data Center Server Performance: Test Data Analysis of Heatsink, Direct Liquid Cooling and Passive 2-Phase Enhanced Air Cooling Based on Loop Heat Pipe
    Vuckovic, Maxime
    Depret, Nicolas
    2016 32ND THERMAL MEASUREMENT, MODELING & MANAGEMENT SYMPOSIUM (SEMI-THERM), 2016, : 71 - 80
  • [30] Energy and Exergy Analysis of a New Cogeneration Heating System Based on Condensed Waste-Heat Utilization in the Direct Air Cooling Coal-Fired Power Plant
    Zhang, Hongsheng
    Liu, Xingang
    Liu, Yifeng
    Hao, Ruijun
    Liu, Chengjun
    Duan, Chenghong
    Dou, Zhan
    Qin, Jiyun
    JOURNAL OF ENERGY ENGINEERING, 2022, 148 (02)