Point-of-care high-sensitivity cardiac troponin in suspected acute myocardial infarction assessed at baseline and 2 h

被引:6
|
作者
Cullen, Louise [1 ,2 ,3 ]
Greenslade, Jaimi [1 ,2 ,3 ]
Parsonage, William [2 ,4 ]
Stephensen, Laura [1 ]
Smith, Stephen W. [5 ]
Sandoval, Yader [6 ,7 ]
Ranasinghe, Isuru [3 ,8 ]
Gaikwad, Niranjan [8 ]
Bayat, Maryam Khorramshahi [8 ]
Mahmoodi, Ehsan [8 ]
Schulz, Karen [9 ]
Than, Martin [10 ]
Apple, Fred S. [9 ,11 ]
机构
[1] Royal Brisbane & Womens Hosp, Emergency & Trauma Ctr, Butterfield St, Herston, Qld 4029, Australia
[2] Queensland Univ Technol, Fac Hlth, Australian Ctr Hlth Serv Innovat, Ctr Healthcare Transformat,Sch Publ Hlth & Social, Musk Ave, Kelvin Grove, Qld 4059, Australia
[3] Univ Queensland, Fac Med, Herston Rd, Herston, Qld 4006, Australia
[4] Royal Brisbane & Womens Hosp, Dept Cardiol, Brisbane, Australia
[5] Univ Minnesota, Hennepin Healthcare Hennepin Cty Med Ctr, Dept Emergency Med, Sch Med, Minneapolis, MN USA
[6] Abbott NW Hosp, Minneapolis Heart Inst, Minneapolis, MN USA
[7] Minneapolis Heart Inst Fdn, Ctr Coronary Artery Dis, Minneapolis, MN USA
[8] Prince Charles Hosp, Dept Cardiol, Brisbane, Qld, Australia
[9] Univ Minnesota, Dept Lab Med & Pathol, Minneapolis, MN USA
[10] Christchurch Hosp, Emergency Dept, Christchurch, New Zealand
[11] Hennepin Healthcare Hennepin Cty Med Ctr, Clin & Forens Toxicol Lab, Minneapolis, MN USA
关键词
Emergency department; Myocardial infarction; High-sensitivity troponin; Rapid diagnostics; Point of care; DIAGNOSIS; GUIDELINES;
D O I
10.1093/eurheartj/ehae343
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Aims Strategies to assess patients with suspected acute myocardial infarction (AMI) using a point-of-care (POC) high-sensitivity cardiac troponin I (hs-cTnI) assay may expedite emergency care. A 2-h POC hs-cTnI strategy for emergency patients with suspected AMI was derived and validated.Methods In two international, multi-centre, prospective, observational studies of adult emergency patients (1486 derivation cohort and 1796 validation cohort) with suspected AMI, hs-cTnI (Siemens Atellica (R) VTLi) was measured at admission and 2 h later. Adjudicated final diagnoses utilized the hs-cTn assay in clinical use. A risk stratification algorithm was derived and validated. The primary diagnostic outcome was index AMI (Types 1 and 2). The primary safety outcome was 30-day major adverse cardiac events incorporating AMI and cardiac death.Results Overall, 81 (5.5%) and 88 (4.9%) patients in the derivation and validation cohorts, respectively, had AMI. The 2-h algorithm defined 66.1% as low risk with a sensitivity of 98.8% [95% confidence interval (CI) 89.3%-99.9%] and a negative predictive value of 99.9 (95% CI 99.2%-100%) for index AMI in the derivation cohort. In the validation cohort, 53.3% were low risk with a sensitivity of 98.9% (95% CI 92.4%-99.8%) and a negative predictive value of 99.9% (95% CI 99.3%-100%) for index AMI. The high-risk metrics identified 5.4% of patients with a specificity of 98.5% (95% CI 96.6%-99.4%) and a positive predictive value of 74.5% (95% CI 62.7%-83.6%) for index AMI.Conclusions A 2-h algorithm using a POC hs-cTnI concentration enables safe and efficient risk assessment of patients with suspected AMI. The short turnaround time of POC testing may support significant efficiencies in the management of the large proportion of emergency patients with suspected AMI. Structured Graphical Abstract Performance of the 0-/2-h algorithm for risk assessment of myocardial infarction in the Suspected Acute Myocardial Infarction in Emergency (SAMIE) and Safe Emergency Department Discharge Rate (SEIGE) cohorts. AMI, acute myocardial infarction; CI, confidence interval; hs-cTnI, high-sensitivity cardiac troponin I; NPV, negative predictive value; POC, point of care; PPV, positive predictive value.
引用
收藏
页码:2508 / 2515
页数:8
相关论文
共 50 条
  • [21] High-sensitivity cardiac troponin on presentation to rule out acute myocardial infarction
    Shah, Anoop S. V.
    Anand, Atul
    Lee, Kuan Ken
    Adamson, Phil
    Chapman, Andrew
    Langdon, Timothy
    Strachan, Fiona
    Newby, David E.
    McAlliste, David A.
    Mills, Nicholas L.
    SCOTTISH MEDICAL JOURNAL, 2016, 61 (04) : NP41 - NP43
  • [22] High-sensitivity cardiac troponin on presentation to rule out acute myocardial infarction
    Shah, A. S.
    Anand, A.
    Lee, K. K.
    Adamson, P.
    Chapman, A.
    Langdon, T.
    Strachan, F.
    McAllister, D.
    Newby, D. E.
    Mills, N. L.
    EUROPEAN HEART JOURNAL, 2015, 36 : 760 - 761
  • [23] Comparison of new point-of-care troponin assay with high sensitivity troponin in diagnosing myocardial infarction
    Aldous, Sally
    Richards, A. Mark
    George, Peter M.
    Cullen, Louise
    Parsonage, William A.
    Flaws, Dylan
    Florkowski, Christopher M.
    Troughton, Richard W.
    O'Sullivan, Jack W.
    Reid, Christopher M.
    Bannister, Laura
    Than, Martin
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 177 (01) : 182 - 186
  • [24] Rising and Falling High-Sensitivity Cardiac Troponin in Diagnostic Algorithms for Patients With Suspected Myocardial Infarction
    Haller, Paul M. M.
    Soerensen, Nils A. A.
    Hartikainen, Tau S. S.
    Gossling, Alina
    Lehmacher, Jonas
    Toprak, Betuel
    Twerenbold, Raphael
    Richter, Janine
    Banko, Thorben
    Korschid, Solaf
    Schmidt, Jakob
    Keller, Till
    Zeller, Tanja
    Blankenberg, Stefan
    Westermann, Dirk
    Neumann, Johannes T. T.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2023, 12 (10):
  • [25] Comparison of Point-of-Care and Central Laboratory Methods for the Measurement of Cardiac Troponin I in Patients With Suspected Acute Myocardial Infarction
    Sekulic, Miroslav
    Santiago, Victor
    Castaneda, Pedro
    Christianson, Eric
    Loppnow, Gregory
    Thompson, James
    Karger, Amy
    Apple, Fred S.
    Li, Danni
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2015, 143 : A2 - A2
  • [26] High-Sensitivity Cardiac Troponin and the Universal Definition of Myocardial Infarction
    Chapman, Andrew R.
    Adamson, Philip D.
    Shah, Anoop S. V.
    Anand, Atul
    Strachan, Fiona E.
    Ferry, Amy V.
    Ken Lee, Kuan
    Berry, Colin
    Findlay, Iain
    Cruikshank, Anne
    Reid, Alan
    Gray, Alasdair
    Collinson, Paul O.
    Apple, Fred
    McAllister, David A.
    Maguire, Donogh
    Fox, Keith A. A.
    Vallejos, Catalina A.
    Keerie, Catriona
    Weir, Christopher J.
    Newby, David E.
    Mills, Nicholas L.
    CIRCULATION, 2020, 141 (03) : 161 - 171
  • [27] Risk stratification with a point-of-care cardiac troponin T test in acute myocardial infarction
    Ohman, EM
    Armstrong, PW
    White, HD
    Granger, CB
    Wilcox, RG
    Weaver, WD
    Gibler, WB
    Stebbins, AL
    Cianciolo, C
    Califf, RM
    Topol, EJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (11): : 1281 - 1286
  • [28] Combining High-Sensitivity Cardiac Troponin I and Cardiac Troponin T in the Early Diagnosis of Acute Myocardial Infarction
    van der Linden, Noreen
    Wildi, Karin
    Twerenbold, Raphael
    Pickering, John W.
    Than, Martin
    Cullen, Louise
    Greenslade, Jaimi
    Parsonage, William
    Nestelberger, Thomas
    Boeddinghaus, Jasper
    Badertscher, Patrick
    Rubini Gimenez, Maria
    Klinkenberg, Lieke J. J.
    Bekers, Otto
    Schoni, Aline
    Keller, Dagmar I.
    Sabti, Zaid
    Puelacher, Christian
    Cupa, Janosch
    Schumacher, Lukas
    Kozhuharov, Nikola
    Grimm, Karin
    Shrestha, Samyut
    Flores, Dayana
    Freese, Michael
    Stelzig, Claudia
    Strebel, Ivo
    Miro, Oscar
    Rentsch, Katharina
    Morawiec, Beata
    Kawecki, Damian
    Kloos, Wanda
    Lohrmann, Jens
    Richards, A. Mark
    Troughton, Richard
    Pemberton, Christopher
    Osswald, Stefan
    van Dieijen-Visser, Marja P.
    Mingels, Alma M.
    Reichlin, Tobias
    Meex, Steven J. R.
    Mueller, Christian
    CIRCULATION, 2018, 138 (10) : 989 - 999
  • [29] Point-of-Care Cardiac Troponin Testing Process Improvements for Detection of Acute Myocardial Infarction
    Apple, Fred S.
    POINT OF CARE, 2006, 5 (01): : 25 - 27
  • [30] Combining glucose and high-sensitivity cardiac troponin in the early diagnosis of acute myocardial infarction
    Ana Yufera-Sanchez
    Pedro Lopez-Ayala
    Thomas Nestelberger
    Karin Wildi
    Jasper Boeddinghaus
    Luca Koechlin
    Maria Rubini Gimenez
    Hüseyin Sakiz
    Paolo Bima
    Oscar Miro
    F. Javier Martín-Sánchez
    Michael Christ
    Dagmar I. Keller
    Danielle M. Gualandro
    Damian Kawecki
    Katharina Rentsch
    Andreas Buser
    Christian Mueller
    Scientific Reports, 13