Hip biomechanics in early recovery following fixation of intertrochanteric fractures: Results from a randomised controlled trial

被引:0
|
作者
Sivakumar, Arjun [1 ]
Bennett, Kieran J. [2 ]
Pizzolato, Claudio [3 ]
Rickman, Mark [4 ]
Thewlis, Dominic [1 ]
机构
[1] Univ Adelaide, Ctr Orthopaed & Trauma Res, Adelaide, SA, Australia
[2] Flinders Univ S Australia, Med Device Res Inst, Adelaide, SA, Australia
[3] Griffith Univ, Griffith Ctr Biomed & Rehabil Engn, Southport, Qld, Australia
[4] Royal Adelaide Hosp, Dept Orthopaed & Trauma, Adelaide, SA, Australia
基金
澳大利亚研究理事会;
关键词
JOINT MOMENTS; CONTACT FORCES; MUSCLE FORCES; BALANCE; NAIL;
D O I
10.1016/j.jbiomech.2024.112169
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Single and dual integrated screw femoral nails are both commonly used to treat intertrochanteric fractures. This study investigated if using single or dual integrated screw femoral nails result in different post-operative hip joint loading. In the presence of differences, we investigated potential contributing factors. Patients were randomised for treatment via single screw (Stryker, Gamma3) or dual-integrated screw nail (Smith and Nephew, Intertan). Pre-injury mobility levels were collected at enrolment. Hip radiographs and gait data were collected at six weeks (Gamma: 16; Intertan: 15) and six months (Gamma: 14; Intertan: 13) follow-up. The resultant hip joint reaction forces and abductor muscle forces were estimated using electromyography-assisted neuromusculoskeletal modelling during level walking gait. Our primary analysis focused on the resultant hip joint reaction force and abductor muscle forces. We compared between groups, across stance phase of walking gait, using statistical parametric mapping. At six weeks, the Intertan group showed a short (similar to 5% of stance phase) but substantial (33 % [0.3 x body weight] greater magnitude) resultant hip joint reaction force when compared to the Gamma group (P = 0.022). Higher gluteus medius forces (P = 0.009) were demonstrated in the Intertan group at six weeks. Harris Hip Scores followed the trend seen for the biomechanical outcomes with superior scores for the Intertan group at six weeks postoperative (P = 0.044). The use of dual-integrated screw femoral nails over single screw devices may allow for hip biomechanics more closely resembling normal hip function at earlier post-operative timepoints, but these appear to resolve by six months postoperative.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Comparison of Functional Recovery in the Very Early Period After Surgery Between Plate and Nail Fixation for Correction of Stable Femoral Intertrochanteric Fractures: A Controlled Clinical Trial of 18 Patients
    Yamauchi, Koun
    Fushimi, Kazunari
    Shirai, Goshi
    Fukuta, Masashi
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2014, 5 (02) : 63 - 68
  • [22] Midterm Outcomes of Intramedullary Fixation of Intertrochanteric Femoral Fractures Using Compression Hip Nails: Radiologic and Clinical Results
    Suh, You-Sung
    Nho, Jae-Hwi
    Song, Min Gon
    Lee, Dong Woo
    Jang, Byung-Woong
    CLINICS IN ORTHOPEDIC SURGERY, 2023, 15 (03) : 373 - 379
  • [23] Computer-assisted navigation for intramedullary nail fixation of intertrochanteric femur fractures: A randomized, controlled trial
    Lilly, Ryan J.
    Koueiter, Denise M.
    Graner, Kelly C.
    Nowinski, Gregory P.
    Sadowski, Jason
    Grant, Kevin D.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (02): : 345 - 350
  • [24] Bed exercises following total hip replacement: a randomised controlled trial
    Smith, Toby O.
    Mann, Charles J. V.
    Clark, Allan
    Donell, Simon T.
    PHYSIOTHERAPY, 2008, 94 (04) : 286 - 291
  • [25] Early functional results with the Mayo-hip, a short stem system with metaphyseal-intertrochanteric fixation
    Hube, R
    Zaage, M
    Hein, W
    Reichel, H
    ORTHOPADE, 2004, 33 (11): : 1249 - +
  • [26] Effect on hip fractures of increased use of hip protectors in nursing homes:: cluster randomised controlled trial
    Meyer, G
    Warnke, A
    Bender, R
    Mühlhauser, I
    BMJ-BRITISH MEDICAL JOURNAL, 2003, 326 (7380): : 76 - 78A
  • [27] Hemiarthroplasty or internal fixation for intracapsular displaced femoral neck fractures: randomised controlled trial
    Frihagen, Frede
    Nordsletten, Lars
    Madsen, Jan Erik
    BMJ-BRITISH MEDICAL JOURNAL, 2007, 335 (7632): : 1251 - 1254
  • [28] Single versus double column fixation in transverse fractures of the acetabulum: A randomised controlled trial
    Fahmy, Mahmoud
    Karim, Mahmoud Abdel
    Khaled, Sherif A.
    Abdelazeem, Ahmed Hazem
    Elnahal, Walid A.
    Elnahal, Ashraf
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (07): : 1291 - 1296
  • [29] The clinical results of a novel method for minimal invasive dynamic hip screw fixation of intertrochanteric fractures compared to the conventional one
    Acar, N.
    Harb, A.
    Albaya, A.
    Kaskin, H.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2017, 43 (05) : 627 - 635
  • [30] The clinical results of a novel method for minimal invasive dynamic hip screw fixation of intertrochanteric fractures compared to the conventional one
    N. Acar
    A. Harb
    A. Albaya
    H. Kaskin
    European Journal of Trauma and Emergency Surgery, 2017, 43 : 627 - 635