Hip biomechanics in early recovery following fixation of intertrochanteric fractures: Results from a randomised controlled trial

被引:0
|
作者
Sivakumar, Arjun [1 ]
Bennett, Kieran J. [2 ]
Pizzolato, Claudio [3 ]
Rickman, Mark [4 ]
Thewlis, Dominic [1 ]
机构
[1] Univ Adelaide, Ctr Orthopaed & Trauma Res, Adelaide, SA, Australia
[2] Flinders Univ S Australia, Med Device Res Inst, Adelaide, SA, Australia
[3] Griffith Univ, Griffith Ctr Biomed & Rehabil Engn, Southport, Qld, Australia
[4] Royal Adelaide Hosp, Dept Orthopaed & Trauma, Adelaide, SA, Australia
基金
澳大利亚研究理事会;
关键词
JOINT MOMENTS; CONTACT FORCES; MUSCLE FORCES; BALANCE; NAIL;
D O I
10.1016/j.jbiomech.2024.112169
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Single and dual integrated screw femoral nails are both commonly used to treat intertrochanteric fractures. This study investigated if using single or dual integrated screw femoral nails result in different post-operative hip joint loading. In the presence of differences, we investigated potential contributing factors. Patients were randomised for treatment via single screw (Stryker, Gamma3) or dual-integrated screw nail (Smith and Nephew, Intertan). Pre-injury mobility levels were collected at enrolment. Hip radiographs and gait data were collected at six weeks (Gamma: 16; Intertan: 15) and six months (Gamma: 14; Intertan: 13) follow-up. The resultant hip joint reaction forces and abductor muscle forces were estimated using electromyography-assisted neuromusculoskeletal modelling during level walking gait. Our primary analysis focused on the resultant hip joint reaction force and abductor muscle forces. We compared between groups, across stance phase of walking gait, using statistical parametric mapping. At six weeks, the Intertan group showed a short (similar to 5% of stance phase) but substantial (33 % [0.3 x body weight] greater magnitude) resultant hip joint reaction force when compared to the Gamma group (P = 0.022). Higher gluteus medius forces (P = 0.009) were demonstrated in the Intertan group at six weeks. Harris Hip Scores followed the trend seen for the biomechanical outcomes with superior scores for the Intertan group at six weeks postoperative (P = 0.044). The use of dual-integrated screw femoral nails over single screw devices may allow for hip biomechanics more closely resembling normal hip function at earlier post-operative timepoints, but these appear to resolve by six months postoperative.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] A double-blind, prospective, randomised, controlled clinical trial of minimally invasive dynamic hip screw fixation of intertrochanteric fractures
    Wong, Tak-Chuen
    Chiu, Yi
    Tsang, Wai-Leuk
    Leung, Wai-Yeung
    Yeung, Sai-Hung
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (04): : 422 - 427
  • [2] Intramedullary fixation of intertrochanteric hip fractures A comparison of two implant designs A prospective randomised clinical trial
    de Grave, Philip Winnock
    Tampere, Thomas
    Byn, Pieter
    Van Overschelde, John
    Pattyn, Christophe
    Verdonk, Rene
    ACTA ORTHOPAEDICA BELGICA, 2012, 78 (02): : 192 - 198
  • [3] Prospective randomised controlled trial of an intramedullary nail versus a sliding hip screw for intertrochanteric fractures of the femur
    Aktselis, Ioannis
    Kokoroghiannis, Constantine
    Fragkomichalos, Evaggelos
    Koundis, Georgios
    Deligeorgis, Anastasios
    Daskalakis, Emmanouil
    Vlamis, John
    Papaioannou, Nikolaos
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (01) : 155 - 161
  • [4] Prospective randomised controlled trial of an intramedullary nail versus a sliding hip screw for intertrochanteric fractures of the femur
    Ioannis Aktselis
    Constantine Kokoroghiannis
    Evaggelos Fragkomichalos
    Georgios Koundis
    Anastasios Deligeorgis
    Emmanouil Daskalakis
    John Vlamis
    Nikolaos Papaioannou
    International Orthopaedics, 2014, 38 : 155 - 161
  • [5] Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial
    Bhandari, Mohit
    Devereaux, P. J.
    Guyatt, Gordon
    Thabane, Lehana
    Walter, Stephen D.
    Heetveld, Martin J.
    Jeray, Kyle J.
    Liew, Susan
    Schemitsch, Emil H.
    Tornetta, Paul, III
    Della Rocca, Gregory J.
    McCormack, Robert
    Oliver, Todd M.
    Segers, Michiel J. M.
    Rangan, Amar
    Richardson, Martin
    Sprague, Sheila
    Slobogean, Gerard P.
    Scott, Taryn
    Garibaldi, Alisha
    Zhou, Qi
    Heels-Ansdell, Diane
    Viveiros, Helena
    Zielinski, Stephanie M.
    Van Lieshout, Esther M. M.
    Johal, Herman
    Hanusch, Birgit C.
    Swiontkowski, Marc
    LANCET, 2017, 389 (10078): : 1519 - 1527
  • [6] Randomised controlled trial of hip protectors for the prevention of second hip fractures
    Birks, YF
    Hildreth, R
    Campbell, P
    Sharpe, C
    Torgerson, DJ
    Watt, I
    AGE AND AGEING, 2003, 32 (04) : 442 - 444
  • [7] Complications Following Short Femoral Nail Fixation for Intertrochanteric Hip Fractures: A Retrospective Study
    Vasilopoulou A.
    Trichonas A.
    Palaiologos K.
    Antonogiannakis E.
    Nikakis C.
    Angelis S.
    Maris S.J.
    Grekas C.
    Karadimas E.J.
    Apostolopoulos A.P.
    Journal of Long-Term Effects of Medical Implants, 2024, 34 (04) : 23 - 32
  • [8] Internal fixation or arthroplasty for displaced cervical hip fractures in the elderly - A randomised controlled trial of 208 patients
    Parker, MJ
    Pryor, GA
    ACTA ORTHOPAEDICA SCANDINAVICA, 2000, 71 (05): : 440 - 446
  • [9] Intramedullary Versus Extramedullary Fixation for Unstable Intertrochanteric Fractures A Prospective Randomized Controlled Trial
    Reindl, Rudolf
    Harvey, Edward J.
    Berry, Gregory K.
    Rahme, Elham
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2015, 97A (23): : 1905 - 1912
  • [10] Internal fixation compared with total hip replacement for displaced femoral neck fractures in the elderly -: A randomised, controlled trial
    Tidermark, J
    Ponzer, S
    Svensson, O
    Söderqvist, A
    Törnkvist, H
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (03): : 380 - 388