Simulation study of a new racetrack FAIMS analyzer to achieve both high-resolution and high-sensitivity

被引:1
|
作者
Fu, Shoushuai [1 ,2 ,3 ]
Wang, Chenlu [1 ,2 ,4 ]
Li, Junhui [1 ,2 ,4 ]
Yu, Jiancheng [1 ,2 ,3 ]
Tang, Keqi [1 ,2 ,4 ]
机构
[1] Ningbo Univ, Inst Mass Spectrometry, Zhejiang Engn Res Ctr Adv Mass Spectrometry & Clin, Ningbo 315211, Peoples R China
[2] Zhenhai Inst Mass Spectrometry, Ningbo 315211, Peoples R China
[3] Ningbo Univ, Fac Elect Engn & Comp Sci, Ningbo 315211, Peoples R China
[4] Ningbo Univ, Sch Mat Sci & Chem Engn, Ningbo 315211, Peoples R China
基金
中国国家自然科学基金;
关键词
Racetrack FAIMS; Resolution; Sensitivity; Ion transmission efficiency; ION MOBILITY SPECTROMETRY; GAS-PHASE SEPARATIONS; MASS-SPECTROMETRY;
D O I
10.1016/j.talanta.2024.126305
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new racetrack field-asymmetric waveform ion mobility spectrometry (r-FAIMS) analyzer was developed in this study by combining the existing planar FAIMS (p-FAIMS) and cylindrical FAIMS (c-FAIMS). The ion inlet and outlet regions of r-FAIMS were consisted of a half of c-FAIMS, respectively, and these c-FAIMS were further connected by two p-FAIMS to form a racetrack shaped FAIMS. With such FAIMS working electrode configuration, the ions entering the r-FAIMS can be focused and separated in the first c-FAIMS section, be further separated in the p-FAIMS section with high-resolution, be focused and separated again in the final c-FAIMS section and eventually enter the mass spectrometer or other analyzers for analysis. Detailed simulation by using SIMION software with the default FAIMS user program showed that the ion focusing effect in the first c-FAIMS section ensures the ions entering the following p-FAIMS section as a compact ion packet. This effectively decreases the ion loss caused by Coulomb repulsion and thermal diffusion in p-FAIMS section as compared to the ions being introduced into the p-FAIMS gap randomly in the conventional design. As a result, the ion transmission efficiency of r-FAIMS is at least 3.3-fold higher than the single p-FAIMS under the operating conditions used in this study. The ion trajectory simulation results also showed that the resolving power of r-FAIMS is about the sum of the resolving powers for its c-FAIMS and p-FAIMS sections. The resolving power of r-FAIMS is at least 3.6-fold higher than the single c-FAIMS under the operation conditions used in this study. Therefore, the r-FAIMS can realize both high-resolution and high-sensitive ion mobility separation.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Racetrack FAIMS for High-Resolution and High-Sensitivity Characterization of Peptide Conformers
    Li, Junhui
    Liu, Rong
    Hu, Zhonghan
    Fu, Shoushuai
    Yu, Jiancheng
    Tang, Keqi
    ANALYTICAL CHEMISTRY, 2024, 96 (34) : 13980 - 13986
  • [2] NEW TECHNIQUES FOR HIGH-SENSITIVITY, HIGH-RESOLUTION SPECTROSCOPY
    EZEKIEL, S
    KVANTOVAYA ELEKTRONIKA, 1978, 5 (08): : 1649 - 1650
  • [3] HIGH-RESOLUTION, HIGH-SENSITIVITY AC CALORIMETER
    BEDNARZ, G
    MILLIER, B
    WHITE, MA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (08): : 3944 - 3952
  • [4] HIGH-RESOLUTION HIGH-SENSITIVITY MASS SPECTROMETERS
    MATSUDA, H
    MASS SPECTROMETRY REVIEWS, 1983, 2 (02) : 299 - 325
  • [5] High-resolution and high-sensitivity PET for quantitative molecular imaging of the monoaminergic nuclei: A GATE simulation study
    Wang, Zipai
    Cao, Xinjie
    LaBella, Andy
    Zeng, Xinjie
    Biegon, Anat
    Franceschi, Dinko
    Petersen, Eric
    Clayton, Nicholas
    Ulaner, Gary A.
    Zhao, Wei
    Goldan, Amir H.
    MEDICAL PHYSICS, 2022, 49 (07) : 4430 - 4444
  • [6] HIGH-SENSITIVITY AND HIGH-RESOLUTION SPECTROSCOPY IN A RING CAVITY
    EZEKIEL, S
    HACKEL, RP
    KARE, J
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1978, 68 (05) : 647 - 648
  • [7] INTEGRATED SILICON MAGNETOTRANSISTORS - HIGH-SENSITIVITY OR HIGH-RESOLUTION
    NATHAN, A
    BALTES, HP
    SENSORS AND ACTUATORS A-PHYSICAL, 1990, 22 (1-3) : 780 - 785
  • [8] HIGH-SENSITIVITY PULSED HIGH-RESOLUTION CARS SPECTROMETER
    VOLKOV, SY
    KOZLOV, DN
    MALIKOV, MR
    OTLIVANCHIK, EA
    SMIRNOV, VV
    KVANTOVAYA ELEKTRONIKA, 1984, 11 (09): : 1851 - 1854
  • [9] High-sensitivity and high-resolution methods for glycoprotein analysis
    Anumula, KR
    ANALYTICAL BIOCHEMISTRY, 2000, 283 (01) : 17 - 26
  • [10] High-sensitivity and high-resolution methods for glycoprotein analysis.
    Anumula, KR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : U113 - U113