GLIDE Score Scoring System for Prediction of Procedural Success in Tricuspid Valve Transcatheter Edge-to-Edge Repair

被引:6
|
作者
Gercek, Muhammed [1 ,2 ]
Narang, Akhil [2 ]
Koerber, M. Isabel [3 ,4 ]
Friedrichs, Kai P. [1 ]
Puthumana, Jyothy J. [2 ]
Ivannikova, Maria [1 ]
Al-Kazaz, Mohamed [2 ]
Cremer, Paul [2 ]
Baldridge, Abigail S. [2 ]
Meng, Zhiying [2 ]
Luedike, Peter [5 ]
Thomas, James D. [2 ]
Rudolph, Tanja K. [1 ]
Geisler, Tobias [6 ]
Rassaf, Tienush
Pfister, Roman [3 ,4 ]
Rudolph, Volker [1 ]
Davidson, Charles J. [2 ]
机构
[1] Ruhr Univ Bochum, Clin Gen & Intervent Cardiol Angiol, Herz & Diabet Zentrum NRW, Georgstr 11, D-32545 Bad Oeynhausen, Germany
[2] Northwestern Univ, Feinberg Sch Med, Chicago, IL USA
[3] Univ Cologne, Fac Med, Dept Internal Med 3, Cologne, Germany
[4] Univ Cologne, Univ Hosp Cologne, Cologne, Germany
[5] Univ Duisburg Essen, Univ Hosp Essen, West German Heart & Vasc Ctr, Dept Cardiol & Vasc Med, Essen, Germany
[6] Eberhard Karls Univ Tubingen, Univ Hosp Tubingen, Dept Cardiol & Angiol, Tubingen, Germany
关键词
transcatheter therapy; tricuspid edge-to-edge valve repair; tricuspid regurgitation; CLINICAL-OUTCOMES; MITRAL-VALVE; REGURGITATION; FEASIBILITY; DEFINITIONS;
D O I
10.1016/j.jcmg.2024.04.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Tricuspid valve transcatheter edge-to-edge repair (T-TEER) is the most widely used transcatheter therapy to treat patients with tricuspid regurgitation (TR). OBJECTIVES The aim of this study was to develop a simple anatomical score to predict procedural outcomes of T-TEER. METHODS All patients (n 1 / 4 168) who underwent T-TEER between January 2017 and November 2022 at 2 centers were included in the derivation cohort. Additionally, 126 patients from 2 separate institutions served as a validation cohort. T-TEER was performed using 2 commercially available technologies. Core laboratory assessment of procedural transesophageal echocardiograms was used to determine septolateral and anteroposterior coaptation gap, lea flet morphology, septal lea flet length and retraction, chordal structure density, tethering height, en face TR jet morphology and TR jet location, image quality, and the presence of intracardiac leads. A scoring system was derived using univariable and multivariable logistic regression. Endpoints assessed were immediate postprocedural TR reduction >= 2 grades and TR grade moderate or less. RESULTS The median age was 82 years (Q1 -Q3: 78-84 years); 48% of patients were women; and patients presented with severe (55%), massive (36%), and torrential (8%) TR. Five variables (septolateral coaptation gap, chordal structure density, en face TR jet morphology, TR jet location, and image quality) were identi fied as best predicting procedural outcome and were incorporated in the GLIDE (Gap, Location, Image quality, density, en-face TR morphology) score (range 0-5). TR reduction >= 2 grades and TR grade moderate or less were observed in >90% of patients with GLIDE scores of 0 and 1 and in only 5.6% and 16.7% of those with GLIDE scores >= 4. The GLIDE score was then externally validated in a separate cohort (area under the curve: 0.77; 95% CI: 0.69-0.86). TR reduction signi ficantly correlated with functional improvement assessed by NYHA functional class and 6-minute walk distance at 3 months. CONCLUSIONS The GLIDE score is a simple, 5-component score that is readily obtained during patient imaging and can predict successful T-TEER. (J Am Coll Cardiol Img 2024;17:729 -742) (c) 2024 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.
引用
收藏
页码:729 / 742
页数:14
相关论文
共 50 条
  • [21] The TriClip system for edge-to-edge transcatheter tricuspid valve repair. A Spanish multicenter study
    Freixa, Xavier
    Arzamendi, Dabit
    del Trigo, Maria
    Luis Cepas-Guillen, Pedro
    Li, Pedro
    Sanchis, Laura
    Barreiro, Manuel
    Regueiro, Ander
    Antonio Baz, Jose
    Asmarats, Lluis
    Calvo, Fran
    Monivas, Vanessa
    Meduina, Irene
    Goicolea, Javier
    Sitges, Marta
    Estevez-Loureiro, Rodrigo
    REVISTA ESPANOLA DE CARDIOLOGIA, 2022, 75 (10): : 797 - 804
  • [22] Three-dimensional echocardiography in transcatheter edge-to-edge tricuspid valve repair
    Orban, M.
    Wolff, S.
    Stolz, L.
    Braun, D.
    Stark, K.
    Mehr, M.
    Stocker, T.
    Orban, M.
    Hagl, C.
    Massberg, S.
    Nabauer, M.
    Hausleiter, J.
    EUROPEAN HEART JOURNAL, 2021, 42 : 268 - 268
  • [23] The Morphologic Spectrum of the Tricuspid Valve Anatomical Implications for Transcatheter Edge-to-Edge Repair
    De Gaspari, Monica
    Layman, Andrew J.
    Pazdernik, Vanessa K.
    Maalouf, Joseph
    Padang, Ratnasari
    Bois, Melanie C.
    Maleszewski, Joseph J.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (07)
  • [24] Personalized Guidance of Edge-to-Edge Transcatheter Tricuspid Valve Repair by Multimodality Imaging
    Patrascu, Alexandru
    Binder, Donat
    Alashkar, Ibrahim
    Schnabel, Peter
    Staehle, Wilfried
    Risha, Osama
    Weinmann, Kai
    Ott, Ilka
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (10)
  • [25] Right ventricular function in transcatheter mitral and tricuspid valve edge-to-edge repair
    Stolz, Lukas
    Doldi, Philipp M.
    Weckbach, Ludwig T.
    Stocker, Thomas J.
    Braun, Daniel
    Orban, Martin
    Wild, Mirjam G.
    Hagl, Christian
    Massberg, Steffen
    Naebauer, Michael
    Hausleiter, Joerg
    Orban, Mathias
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [26] The safety of transesophageal echocardiography to guide transcatheter tricuspid valve edge-to-edge repair
    Cammalleri, Valeria
    De Luca, Valeria Maria
    Antonelli, Giorgio
    Piscione, Maria Grazia
    Gaudio, Dario
    Carpenito, Myriam
    Mega, Simona
    di Pumpo, Anna Laura
    Carassiti, Massimiliano
    Grigioni, Francesco
    Ussia, Gian Paolo
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2024, 41 (06):
  • [27] Tricuspid Transcatheter Edge-to-Edge Valve Repair Sooner Rather Than Later
    Messika-Zeitoun, David
    Burwash, Ian G.
    Dreyfus, Julien
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (02) : 190 - 192
  • [28] TRI-SCORE is superior to EuroSCORE II and STS-Score in mortality prediction following transcatheter edge-to-edge tricuspid valve repair
    Groeger, Matthias
    Friedl, Sophia
    Ouerghemmi, Dhia
    Tadic, Marijana
    Bruss, Elene
    Felbel, Dominik
    Paukovitsch, Michael
    Schneider, Leonhard M.
    Dahme, Tillman
    Rottbauer, Wolfgang
    Markovic, Sinisa
    Kessler, Mirjam
    CLINICAL RESEARCH IN CARDIOLOGY, 2023, 112 (10) : 1436 - 1445
  • [29] Residual tricuspid regurgitation after transcatheter tricuspid valve edge-to-edge repair: the EuroTR Registry
    Stolz, L.
    Lurz, P.
    Iliadis, C.
    Rudolph, V
    Kalbacher, D.
    Kessler, M.
    Praz, F.
    Lauten, P.
    Maisano, F.
    Karam, N.
    Luedike, P.
    Estevez-Loureiro, R.
    Metra, M.
    Thiele, H.
    Hausleiter, J.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [30] Outcome Prediction score for mitral transcatheter edge-to-edge repair in patients with concomitant significant tricuspid regurgitation
    Shechter, Alon
    Kaewkes, Danon
    Patel, Vivek
    Vaturi, Mordehay
    Wangmang, Felix
    Koseki, Keita
    Koren, Ofir
    Nagasaka, Takashi
    Makar, Moody
    Chakravarty, Tarun
    Skaf, Sabah
    Makkar, Raj R.
    Siegel, Robert J.
    HELLENIC JOURNAL OF CARDIOLOGY, 2024, 78 : 3 - 15