VENTILATION SYSTEM PERFORMANCE ON THE REMOVAL OF RESPIRATORY DROPLETS EMITTED DURING SPEAKING

被引:0
|
作者
Masoomi, Morteza Ali [1 ]
Salmanzadeh, Mazyar [1 ]
Ahmadi, Goodarz [2 ]
机构
[1] Shahid Bahonar Univ Kerman, Dept Mech Engn, Kerman, Iran
[2] Clarkson Univ, Dept Mech & Aerosp Engn, Potsdam, NY USA
来源
PROCEEDINGS OF ASME 2022 FLUIDS ENGINEERING DIVISION SUMMER MEETING, FEDSM2022, VOL 2 | 2022年
关键词
CFD simulation; ventilation; particles; speaking; infectious disease;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The SARS-CoV-2 infection pandemic has led to significant loss of lives and worldwide economic disruption. The leading cause of transmission of infectious respiratory diseases is through aerosolized mucous and salivary droplets containing the virus emitted into the environment through respiratory activities. Depending on their initial size, the droplets evaporate or fall to the ground due to gravitational sedimentation. When a droplet evaporates, the droplet nucleus containing all the viruses in the original droplet remains airborne in the environment for a long duration of time. The ventilation system significantly affects the dispersion and removal of particles from the environment. Therefore, poorly ventilated indoor environments increase the risk of disease transmission. The present study modeled a ventilated small office space with two mannequins sitting across a table. It was assumed that one of the mannequins was speaking and emitting small droplets. Then the effect of the ventilation system on the droplets' transport and dispersion was simulated. In particular, the performance of the displacement and mixing ventilation systems on particle dispersion and deposition in the room were evaluated and compared. These simulations were performed using the computational fluid dynamics (CFD) approach with Ansys-Fluent software. The Eulerian approach was used to simulate the airflow field in the room, and the Lagrangian trajectory analysis approach was used for the droplets. Experimental data of the thermal plume above the mannequin's head were used to validate the airflow simulation results. The results showed that the displacement ventilation system has better performance (almost three times more) in removing particles from the environment than the mixing ventilation system.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Analysis of respiratory mechanics during artificial ventilation
    Guttmann, J
    BIOMEDIZINISCHE TECHNIK, 1998, 43 (04): : 107 - 115
  • [42] EVALUATION OF RESPIRATORY MECHANICS DURING MECHANICAL VENTILATION
    SIMILOWSKI, T
    MILICEMILI, J
    PRESSE MEDICALE, 1989, 18 (36): : 1791 - 1796
  • [43] Monitoring respiratory mechanics during assisted ventilation
    Grasselli, Giacomo
    Brioni, Matteo
    Zanella, Alberto
    CURRENT OPINION IN CRITICAL CARE, 2020, 26 (01) : 11 - 17
  • [44] The determinants of respiratory rate during mechanical ventilation
    Tobert, DG
    Simon, PM
    Stroetz, RW
    Hubmayr, RD
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 155 (02) : 485 - 492
  • [45] Advances in respiratory monitoring during mechanical ventilation
    Jubran, A
    CHEST, 1999, 116 (05) : 1416 - 1425
  • [46] Respiratory control during independent lung ventilation
    Officer, TM
    Wheeler, DR
    Frost, AE
    Rodarte, JR
    CHEST, 2001, 120 (02) : 678 - 681
  • [47] Ventilation and respiratory exchanges during polypnea.
    Garrelon, L
    Langlois, JP
    COMPTES RENDUS DES SEANCES DE LA SOCIETE DE BIOLOGIE ET DE SES FILIALES, 1908, 57 : 81 - 83
  • [48] Reliability of Respiratory System Compliance Calculation During Assisted Mechanical Ventilation: A Retrospective Study
    Bastia, Luca
    Amendolagine, Liliana
    Pozzi, Federico
    Carenini, Stefano
    Cipolla, Cristiana
    Curto, Francesco
    Bellani, Giacomo
    Fumagalli, Roberto
    Chieregato, Arturo
    CRITICAL CARE MEDICINE, 2023, 51 (10) : E201 - E205
  • [49] Robustness of two different methods of monitoring respiratory system compliance during mechanical ventilation
    Perchiazzi, Gaetano
    Rylander, Christian
    Pellegrini, Mariangela
    Larsson, Anders
    Hedenstierna, Goran
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (10) : 1819 - 1828
  • [50] LOW-FREQUENCY RESPIRATORY SYSTEM RESISTANCE IN THE NORMAL DOG DURING MECHANICAL VENTILATION
    SATO, J
    DAVEY, BLK
    SHARDONOFSKY, F
    BATES, JHT
    JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (04) : 1536 - 1543