Standard Total Ankle Arthroplasty vs. Patient-Specific Instrumentation: A Comparative Study

被引:1
|
作者
Arceri, Alberto [1 ]
Abdi, Pejman [1 ]
Mazzotti, Antonio [1 ,2 ]
Zielli, Simone Ottavio [1 ]
Artioli, Elena [1 ]
Langone, Laura [1 ]
Sgubbi, Federico [1 ]
Faldini, Cesare [1 ,2 ]
机构
[1] Ist Ortoped Rizzoli, Ist Ricovero & Cura Carattere Sci IRCCS, Orthopaed & Traumatol Clin 1, I-40136 Bologna, Italy
[2] Alma Mater Studiorum Univ Bologna, Dept Biomed & Neuromotor Sci DIBINEM, Bologna, Italy
来源
JOURNAL OF PERSONALIZED MEDICINE | 2024年 / 14卷 / 07期
关键词
total ankle arthroplasty; patient-specific instrumentation; surgical outcomes; retrospective analysis; complications; REPLACEMENT; DEFORMITY; OUTCOMES; MOTION; RANGE; VARUS;
D O I
10.3390/jpm14070770
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Purpose: This retrospective study aims to compare surgical outcomes between two cohorts of patients who underwent total ankle arthroplasty (TAA) using either standard technique or patient-specific instrumentation (PSI). Methods: A consecutive series of patients who affected of end-staged ankle osteoarthritis were retrospectively assessed and divided into two groups based on TAA techniques: a TAA standard technique group and a TAA-using PSI group. The two groups were compared in terms of operative time, additional procedures, complications (neurovascular and wound problems, infection, loosening and osteolysis, revision and explantation rates, and perioperative fracture), clinical scores, and range of motion (ROM). Result: Fifty-one patients underwent standard TAA, while 13 patients underwent TAA with PSI. At 1-year follow-up, there were no significant differences in complication rates between the two groups (p > 0.05). AOFAS scores were similar, with the standard TAA group scoring 83.33 +/- 7.55 and the PSI group scoring 82.92 +/- 9.7 (p = 0.870). Likewise, the postoperative ROM did not differ significantly, with 15.12 +/- 7.6 degrees for the standard TAA group and 16.05 +/- 6.7 degrees for the PSI group (p = 0.689). However, the standard TAA group experienced significantly longer operative time (107.1 +/- 22.1 min) compared to the PSI group (91.92 +/- 22.9 min, p = 0.032). Additionally, the standard TAA group required more adjunctive procedures (29.7%) compared to the PSI group (7.7%, p = 0.04). Residual pain was also more frequently reported in the standard TAA group (62.7%) than in the PSI group (30.7%, p = 0.038). Conclusion: While both techniques resulted in comparable complication rates, clinical scores and ROM, the PSI group reported significantly shorter operative time and less residual pain, thus requiring fewer postoperative procedures.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Patient-Specific Instrumentation in Total Knee Arthroplasty: What Is the Evidence?
    Szczech, Bartlomiej
    McDermott, James D.
    Issa, Kimona
    Rifai, Aiman
    Festa, Anthony
    Matarese, William A.
    McInerney, Vincent K.
    JOURNAL OF KNEE SURGERY, 2016, 29 (04) : 341 - 345
  • [22] Reliability of Templating with Patient-Specific Instrumentation in Total Knee Arthroplasty
    Issa, Kimona
    Rifai, Aiman
    McGrath, Mike S.
    Callaghan, John J.
    Wright, Craig
    Malkani, Arthur L.
    Mont, Michael A.
    McInerney, Vincent K.
    JOURNAL OF KNEE SURGERY, 2013, 26 (06) : 429 - 433
  • [23] Patient-specific instrumentation makes sense in total knee arthroplasty
    Leon-Munoz, Vicente J.
    Lopez-Lopez, Mirian
    Santonja-Medina, Fernando
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (06) : 489 - 497
  • [24] Total Knee Arthroplasty: Validating The Benefits Of Patient-Specific Instrumentation
    Moore, S.
    Linton, K. N.
    Martin, P.
    Headon, R. J.
    Bennett, D.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2018, 187 : S74 - S75
  • [25] Accuracy of Patient-Specific Instrumentation Compared With Conventional Instrumentation in Total Knee Arthroplasty
    Jiang, Jin
    Kang, Xin
    Lin, Qiao
    Teng, Yuanjun
    An, Liping
    Ma, Jingling
    Wang, Jing
    Xia, Yayi
    ORTHOPEDICS, 2015, 38 (04) : E305 - E313
  • [26] Patient-specific instrumentation and custom total knee implants in total knee arthroplasty
    Isaacson, Mark
    Bunn, Kevin
    Incavo, Stephen
    CURRENT ORTHOPAEDIC PRACTICE, 2015, 26 (03): : 224 - 227
  • [27] Single-use, patient-specific instrumentation technology in knee arthroplasty: a comparative study between standard instrumentation and PSI efficiency system
    Giannotti S.
    Sacchetti F.
    Citarelli C.
    Bottai V.
    Bianchi N.
    Agostini G.
    Capanna R.
    MUSCULOSKELETAL SURGERY, 2020, 104 (2) : 195 - 200
  • [28] Accuracy of CT-Derived Patient-Specific Instrumentation for Total Ankle Arthroplasty: The Impact of the Severity of Preoperative Varus Ankle Deformity
    Umbel, Benjamin D. D.
    Hockman, Taylor
    Myers, Devon
    Sharpe, B. Dale
    Berlet, Gregory C. C.
    FOOT & ANKLE SPECIALIST, 2023, 16 (03) : 205 - 213
  • [29] Contact kinematics of patient-specific instrumentation versus conventional instrumentation for total knee arthroplasty
    Broberg, Jordan S.
    Naudie, Douglas D. R.
    Howard, James L.
    Vasarhelyi, Edward M.
    McCalden, Richard W.
    Teeter, Matthew G.
    KNEE, 2020, 27 (05): : 1501 - 1509
  • [30] Does Patient-Specific Instrumentation Have a Higher Rate of Early Osteolysis Than Standard Referencing Techniques in Total Ankle Arthroplasty? A Radiographic Analysis
    Escudero, Mario I.
    Symes, Michael
    Bemenderfer, Thomas Bradford
    Barahona, Maximiliano
    Anderson, Robert
    Davis, Hodges
    Wing, Kevin J.
    Penner, Murray J.
    FOOT & ANKLE SPECIALIST, 2020, 13 (01) : 32 - 42