Seismic performance evaluation of a steel slit damper for retrofit of structures on soft soil

被引:0
|
作者
Nasab, Mahammad Seddiq Eskandari [1 ]
Kim, Jinkoo [2 ]
Ahn, Tae -Sang [2 ]
机构
[1] Sungkyunkwan Univ, Dept Civil & Architectural Engn, Suwon, South Korea
[2] Korea Disaster Prevent Technol, Seoul, South Korea
来源
STEEL AND COMPOSITE STRUCTURES | 2024年 / 51卷 / 01期
关键词
nonlinear dynamic analysis; seismic retrofit; soil -structure interaction; steel slit dampers; BUCKLING RESTRAINED BRACES; BEHAVIOR; FRAMES; SYSTEM; DEVICE;
D O I
10.12989/scs.2024.51.1.093
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental and analytical study on a steel slit damper designed as an energy dissipative device for earthquake protection of structures considering soil-structure interaction. The steel slit damper is made of a steel plate with a number of slits cut out of it. The slit damper has an advantage as a seismic energy dissipation device in that the stiffness and the yield force of the damper can be easily controlled by changing the number and size of the vertical strips. Cyclic loading tests of the slit damper are carried out to verify its energy dissipation capability, and an analytical model is developed validated based on the test results. The seismic performance of a case study building is then assessed using nonlinear dynamic analysis with and without soil-structure interaction. The soil-structure system turns out to show larger seismic responses and thus seismic retrofit is required to satisfy a predefined performance limit state. The developed slit dampers are employed as a seismic energy dissipation device for retrofitting the case study structure taking into account the soil-structure interaction. The seismic performance evaluation of the model structure shows that the device works stably and dissipates significant amount of seismic energy during earthquake excitations, and is effective in lowering the seismic response of structures standing on soft soil.
引用
收藏
页码:93 / 101
页数:9
相关论文
共 50 条
  • [21] A steel hysteretic damper for seismic design and retrofit of precast portal frames
    Javidan, Mohammad Mahdi
    Ali, Amir
    Kim, Jinkoo
    JOURNAL OF BUILDING ENGINEERING, 2022, 57
  • [22] Seismic Retrofit of an Existing Steel Arch Bridge Using Viscous Damper
    Kandemir, E. C.
    Mazda, T.
    Nurui, H.
    Miyamoto, H.
    PROCEEDINGS OF THE TWELFTH EAST ASIA-PACIFIC CONFERENCE ON STRUCTURAL ENGINEERING AND CONSTRUCTION (EASEC12), 2011, 14
  • [23] A steel hysteretic damper for seismic design and retrofit of precast portal frames
    Javidan, Mohammad Mahdi
    Ali, Amir
    Kim, Jinkoo
    JOURNAL OF BUILDING ENGINEERING, 2022, 57
  • [24] Seismic Performance Evaluation and Retrofit of Fixed Jacket Offshore Platform Structures
    El-Din, Mohamed Nour
    Kim, Jinkoo
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2015, 29 (04)
  • [25] Tuned liquid damper for vibration mitigation of seismic-excited structures on soft soil
    Abd-Elhamed, Ayman
    Tolan, Mohamed
    ALEXANDRIA ENGINEERING JOURNAL, 2022, 61 (12) : 9583 - 9599
  • [26] Fluid Viscous Damper-Based Seismic Retrofit Strategies of Steel Structures: General Concepts and Design Applications
    Sorace, Stefano
    Terenzi, Gloria
    ADVANCED STEEL CONSTRUCTION, 2009, 5 (03): : 325 - 342
  • [27] Seismic design, evaluation and retrofit of steel bridges
    Astaneh-Asl, A
    INNOVATION IN ENGINEERING FOR SEISMIC REGIONS, 1997, : 27 - 39
  • [28] Seismic Retrofit of Structures Using Steel Honeycomb Dampers
    Lee, Minhee
    Lee, Joonho
    Kim, Jinkoo
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2017, 17 (01) : 215 - 229
  • [29] Seismic retrofit of structures using steel honeycomb dampers
    Minhee Lee
    Joonho Lee
    Jinkoo Kim
    International Journal of Steel Structures, 2017, 17 : 215 - 229
  • [30] Seismic evaluation and retrofit of reinforced concrete structures
    Mangeshkumar R. Shendkar
    Adithya Tantri
    Asha Udaya Rao
    Journal of Infrastructure Preservation and Resilience, 6 (1):