Size of Self-Expandable Transcatheter Heart Valve and Mid-Term Adverse Events After Transcatheter Aortic Valve Replacement

被引:0
|
作者
Hioki, Hirofumi [1 ,14 ,15 ]
Yamamoto, Masanori [2 ,3 ,4 ]
Watanabe, Yusuke [5 ]
Ohno, Yohei
Yashima, Fumiaki [6 ]
Naganuma, Toru [7 ,16 ]
Tada, Norio [8 ]
Shirai, Shinichi [9 ]
Yamanaka, Futoshi
Mizutani, Kazuki
Otsuka, Toshiaki [17 ]
Noguchi, Masahiko
Izumo, Masaki [11 ]
Takagi, Kensuke [10 ,18 ]
Asami, Masahiko [12 ,13 ]
机构
[1] IMS Tokyo Katsushika Gen Hosp, Dept Gastroenterol, Tokyo, Japan
[2] Toyohashi Heart Ctr, Dept Cardiol, Toyohashi, Japan
[3] Nagoya Heart Ctr, Dept Cardiol, Nagoya, Japan
[4] Gifu Heart Ctr, Dept Cardiol, Gifu, Japan
[5] Teikyo Univ Hosp, Dept Cardiol, Tokyo, Japan
[6] Saiseikai Utsunomiya Hosp, Dept Cardiol, Utsunomiya, Tochigi, Japan
[7] New Tokyo Hosp, Dept Cardiol, Matsudo, Japan
[8] Sendai Kosei Hosp, Dept Cardiol, Sendai, Japan
[9] Kokura Mem Hosp, Dept Cardiol, Kokura, Japan
[10] Kinki Univ, Dept Cardiol, Osaka, Japan
[11] St Marianna Univ, Dept Cardiol, Tokyo, Japan
[12] Natl Cerebral & Cardiovasc Ctr, Dept Cardiol, Osaka, Japan
[13] Mitsui Mem Hosp, Div Cardiol, Tokyo, Japan
[14] Toyama Univ Hosp, Dept Cardiol, Toyama, Japan
[15] Tsukuba Med Ctr Hosp, Dept Cardiol, Tsukuba, Japan
[16] Nippon Med Sch, Dept Hyg & Publ Hlth, Tokyo, Japan
[17] Nippon Med Sch, Ctr Clin Res, Tokyo, Japan
[18] Keio Univ, Sch Med, Div Cardiol, Tokyo, Japan
来源
关键词
aortic stenosis; prognosis; self -expandable valve; TAVR; PROSTHESIS-PATIENT MISMATCH; CLINICAL-OUTCOMES; IMPLANTATION; REGURGITATION; HEMODYNAMICS; ASSOCIATION; STENOSIS; FAILURE; IMPACT;
D O I
10.1016/j.amjcard.2024.05.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The hemodynamic performance of self-expandable valves (SEVs) is a preferable choice for small aortic annuli in transcatheter aortic valve replacement (TAVR). However, no data are, so far, available regarding the relation between the size of SEVs and clinical outcomes. This study aimed to evaluate the impact of prosthesis size on adverse events after TAVR using SEVs. We retrospectively analyzed 1,400 patients (23-mm SEV: 13.6%) who underwent TAVR using SEVs at 12 centers. The impact of SEV size on all-cause death and heart failure (HF) after TAVR was evaluated by multivariate Cox regression and propensity score (PS) matching analysis. During the follow-up period (median 511 days), 201 all-cause deaths and 87 HF rehospitalizations were observed. The incidence of all-cause death was comparable between small- (23-mm SEV) and larger-sized (26- or 29-mm SEV) (16.8% vs 13.9%, log-rank p = 0.29). The size of SEV was not associated with a higher incidence of all-cause death (hazard ratio [HR] 1.21, 95% confidence interval [CI] 0.79 to 1.86 in Cox regression; HR 1.31, 95% CI 0.77 to 2.23 in PS matching) and HF after TAVR (subdistribution HR 0.79, 95% CI 0.37 to 1.72 in Cox regression; subdistribution HR 1.00, 95% CI 0.44 to 2.30 in PS matching). The multivariate model including postprocedural prosthesis-patient mismatch showed consistent results. In conclusion, small SEVs had comparable midterm clinical outcomes to larger-sized SEVs, even if the prosthesis-patient mismatch was observed after TAVR. (c) 2024 Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页码:156 / 164
页数:9
相关论文
共 50 条
  • [31] A computational optimization study of a self-expandable transcatheter aortic valve
    Barati, Sara
    Fatouraee, Nasser
    Nabaei, Malikeh
    Berti, Francesca
    Petrini, Lorenza
    Migliavacca, Francesco
    Rodriguez Matas, Jose Felix
    COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 139
  • [32] Long-term clinical outcome and performance of transcatheter aortic valve replacement with a self-expandable bioprosthesis
    Testa, Luca
    Latib, Azeem
    Brambilla, Nedy
    De Marco, Federico
    Fiorina, Claudia
    Adamo, Marianna
    Giannini, Cristina
    Angelillis, Marco
    Barbanti, Marco
    Sgroi, Carmelo
    Poli, Arnaldo
    Ferrara, Erica
    Bruschi, Giuseppe
    Russo, Claudio Francesco
    Matteo, Montorfano
    De Felice, Francesco
    Musto, Carmine
    Curello, Salvatore
    Colombo, Antonio
    Tamburino, Corrado
    Petronio, Anna Sonia
    Bedogni, Francesco
    EUROPEAN HEART JOURNAL, 2020, 41 (20) : 1876 - 1886
  • [33] Self-Expandable Valves and Aortic Angulation Adversely Impact Transcatheter Aortic Valve Replacement Outcomes
    Musallam, Anees
    Rogers, Toby
    Chezar-Azerrad, Chava
    Case, Brian
    Yerasi, Charan
    Forrestal, Brian
    Shea, Corey
    Zhang, Cheng
    Khalid, Nauman
    Khan, Jaffar
    Satler, Lowell
    Ben-Dor, Itsik
    Waksman, Ron
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B203 - B204
  • [34] Transcatheter Self-Expandable Aortic Valve Implantation After Undersized Mitral Annuloplasty
    Bruschi, Giuseppe
    De Marco, Federico
    Oreglia, Jacopo
    Colombo, Paola
    Barosi, Alberto
    Einaudi, Arturo
    Paino, Roberto
    Martinelli, Luigi
    Klugmann, Silvio
    ANNALS OF THORACIC SURGERY, 2011, 92 (05): : 1881 - 1883
  • [35] Pacemaker implantation after balloon- or self-expandable transcatheter aortic valve replacement in patients with aortic stenosis
    Bodin, A.
    Bisson, A.
    Herbert, J.
    Lacour, T.
    Saint Etienne, C.
    Pierre, B.
    Deharo, P.
    Babuty, D.
    Clementy, N.
    Fauchier, L.
    EUROPEAN HEART JOURNAL, 2020, 41 : 714 - 714
  • [36] Clinical and structural outcomes of neocommissural alignment in transaxillary and transcarotid transcatheter aortic valve implantation with a self-expandable transcatheter heart valve
    Mosquera, Victor X.
    Muinelo-Paul, Adrian
    Pato-Lopez, Oscar
    Bouzas-Mosquera, Alberto
    Cuenca-Castillo, Jose J.
    JTCVS TECHNIQUES, 2023, 22 : 150 - 158
  • [37] Stent-frame decoupling following self-expandable transcatheter aortic valve replacement
    Moscarelli, Marco
    Sollami, Giulia
    Violante, Francesco
    Cuffari, Federico
    Di Pasquale, Claudia
    Speziale, Giuseppe
    Giannini, Francesco
    Vadala, Giuseppe
    Galassi, Alfredo Ruggero
    Fattouch, Khalil
    Lentini, Emanuele
    Prestera, Rosa
    Pernice, Vincenzo
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2024, 18 (01) : 105 - 108
  • [38] Echocardiographic Imaging of Procedural Complications During Self-Expandable Transcatheter Aortic Valve Replacement
    Hahn, Rebecca T.
    Gillam, Linda D.
    Little, Stephen H.
    JACC-CARDIOVASCULAR IMAGING, 2015, 8 (03) : 319 - 336
  • [39] Pacemaker Implantation After Balloon- or Self-Expandable Transcatheter Aortic Valve Replacement in Patients With Aortic Stenosis
    Bisson, Arnaud
    Bodin, Alexandre
    Herbert, Julien
    Lacour, Thibaut
    Saint Etienne, Christophe
    Pierre, Bertrand
    Clementy, Nicolas
    Deharo, Pierre
    Babuty, Dominique
    Fauchier, Laurent
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2020, 9 (09):
  • [40] Mid-Term Outcomes after Transcatheter Aortic Valve Replacement With a Mechanically-Expanded Versus Self-Expandable Valve: 3-Year Results From the REPRISE III Randomized Trial
    Rizik, David
    Rajagopal, Vivek
    Bajwa, Tanvir
    Southard, Jeffrey
    Yakubov, Steven
    Cutlip, Donald
    Teirstein, Paul
    Ihlberg, Leo
    Allocco, Dominic
    Reardon, Michael
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B76 - B76