Influence of maximum diameter on fine-needle aspiration biopsy outcomes in ACR TI-RADS 5 thyroid nodules

被引:0
|
作者
Cao, Shi-Liang [1 ]
Shi, Wan-Ying [2 ,3 ]
Niu, Yi-Ru [4 ]
Zhao, Zhen-Long [1 ]
Wei, Ying [1 ]
Wu, Jie [1 ]
Peng, Li-Li [1 ]
Li, Yan [1 ]
Yu, Ming-An [1 ]
机构
[1] China Japan Friendship Hosp, Dept Intervent Med, Beijing, Peoples R China
[2] Capital Med Univ, Sch Publ Hlth, Dept Epidemiol & Hlth Stat, Beijing, Peoples R China
[3] Beijing Municipal Key Lab Clin Epidemiol, Beijing, Peoples R China
[4] China Japan Friendship Hosp, Pathol Dept, Beijing, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
fine needle aspiration; thyroid nodule; restricted cubic spline (RCS); diagnosis; ultrasound; KOREAN SOCIETY; MANAGEMENT; CANCER; SIZE; DIAGNOSIS; ADEQUACY; CYTOLOGY; SYSTEM; RISK; AGE;
D O I
10.3389/fendo.2024.1374888
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Fine needle aspiration (FNA) biopsy is a widely accepted method for diagnosing thyroid nodules. However, the influence of maximum diameter (MD) of ACR TIRADS 5 (TR5) thyroid nodules on the FNA outcomes remains debated. This study examined the influence of MD on the FNA outcomes and investigated the optimal MD threshold for FNA in TR5 nodules. Methods: We conducted a retrospective analysis of 280 TR5 thyroid nodules from 226 patients who underwent FNA from January to June 2022 in our department. Probably malignant (PM) group was defined as Bethesda V in cytopathology with confirmed BRAF V600E mutation or Bethesda VI, the other cytopathology outcomes were defined as probably benign (PB) group. We examined factors influencing malignant cytopathology outcomes and determined the optimal MD threshold for FNA in TR5 nodules using logistic regression and restricted cubic spline (RCS) analysis. Results: Among these nodules, 58.2% (163/280) had PM outcomes. The PM group had a significantly larger MD than the PB group [6.5mm (range 5.0-8.4) vs. 5.3mm (range 4.0-7.0), p < 0.001]. In multivariate logistic regression fully adjusted for confounders, MD was significantly associated with PM outcomes [odds ratio 1.16, 95%CI 1.05-1.31; p = 0.042]. The highest quartile of MD had a greater likelihood of PM outcomes compared to the lowest quartile [odds ratio 4.71, 95% CI 1.97-11.69, p = 0.001]. The RCS analysis identified 6.2 mm as the optimal MD threshold for FNA in TR5 nodules. Conclusion: MD significantly affects the probability of malignant outcomes in FNA of TR5 thyroid nodules. A MD threshold of >= 6.2mm is suggested for FNA in these nodules.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Management of Thyroid Nodules with Atypical Cytology on Fine-needle Aspiration Biopsy
    Nagarkatti, Sushruta S.
    Faquin, William C.
    Lubitz, Carrie C.
    Garcia, Dieter Morales
    Barbesino, Giuseppe
    Ross, Douglas S.
    Hodin, Richard A.
    Daniels, Gilbert H.
    Parangi, Sareh
    ANNALS OF SURGICAL ONCOLOGY, 2013, 20 (01) : 60 - 65
  • [42] Clinical Efficacy of Fine-Needle Aspiration Biopsy of Thyroid Nodules in Males
    Schiro, Adam J.
    Pinchot, Scott N.
    Chen, Herbert
    Sippel, Rebecca S.
    JOURNAL OF SURGICAL RESEARCH, 2010, 159 (02) : 645 - 650
  • [43] Fine-needle aspiration biopsy versus ultrasoundguided fine-needle aspiration biopsy: Costeffectiveness as a frontline diagnostic modality for solitary thyroid nodules
    Khalid, Ayesha N.
    Quraishi, Sadeq A.
    Hollenbeak, Christopher S.
    Stack, Brendan C., Jr.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2008, 30 (08): : 1035 - 1039
  • [44] Factors That Affect the False-Negative Outcomes of Fine-Needle Aspiration Biopsy in Thyroid Nodules
    Agcaoglu, Orhan
    Aksakal, Nihat
    Ozcinar, Beyza
    Sarici, Inanc S.
    Ercan, Gulcin
    Kucukyilmaz, Meltem
    Yanar, Fatih
    Ozemir, Ibrahim A.
    Kilic, Berkay
    Caglayan, Kasim
    Yilmazbayhan, Dilek
    Salmaslioglu, Artur
    Issever, Halim
    Ozarmagan, Selcuk
    Erbil, Yesim
    INTERNATIONAL JOURNAL OF ENDOCRINOLOGY, 2013, 2013
  • [45] Ultrasound-Guided Fine-Needle Aspiration Biopsy of Thyroid Nodules Smaller Than 5 mm in the Maximum Diameter: Assessment of Efficacy and Pathological Findings
    Kim, Dong Wook
    Park, Auh Whan
    Lee, Eun Joo
    Choo, Hye Jung
    Kim, Sang Hyo
    Lee, Sang Hyub
    Eom, Jae Wook
    KOREAN JOURNAL OF RADIOLOGY, 2009, 10 (05) : 435 - 440
  • [46] FINE-NEEDLE ASPIRATION OF THYROID-NODULES
    WOLTERING, EA
    WESTERN JOURNAL OF MEDICINE, 1987, 146 (06): : 737 - 738
  • [47] Fine-Needle Aspiration of Thyroid Nodules with Macrocalcification
    Lee, Jisun
    Lee, Seung Young
    Cha, Sang-Hoon
    Cho, Bum Sang
    Kang, Min Ho
    Lee, Ok-Jun
    THYROID, 2013, 23 (09) : 1106 - 1112
  • [48] Core needle biopsy in the management of thyroid nodules with an indeterminate fine-needle aspiration report
    Yim, Younghee
    Baek, Jung Hwan
    GLAND SURGERY, 2019, 8 : S77 - S85
  • [49] Fine needle aspiration biopsy of thyroid nodules
    Arda, IS
    Yildirim, S
    Demirhan, B
    Firat, S
    ARCHIVES OF DISEASE IN CHILDHOOD, 2001, 85 (04) : 313 - 317
  • [50] Comparison of palpation-guided fine-needle aspiration biopsy to ultrasound-guided fine-needle aspiration biopsy in the evaluation of thyroid nodules
    Cesur, Mustafa
    Corapcioglu, Demet
    Bulut, Safak
    Gursoy, Alptekin
    Yilmaz, Arif Ender
    Erdogan, Nural
    Kamel, Nuri
    THYROID, 2006, 16 (06) : 555 - 561